    1 W415-0583 / D / 07.24.07 INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED T O AND REMAIN WITH THE HOMEOWNER. GD82NT -T NA TURAL GAS GD82PT -T PROP ANE W ARN ...

  • Napoleon Fireplaces GD82PT-T - page 2

    2 W415-0583 / D / 07.24.07 PG 2-5 INTRODUCTION W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T erminal Locations 10-15 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Fireplace V ent Connection Using Rigid V ...

  • Napoleon Fireplaces GD82PT-T - page 3

    3 W415-0583 / D / 07.24.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. N APOLEON® products are manuf actured under the strict Standard of the ...

  • Napoleon Fireplaces GD82PT-T - page 4

    4 W415-0583 / D / 07.24.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace. Never obstruct the front opening of the fi replace. Objects placed in front ...

  • Napoleon Fireplaces GD82PT-T - page 5

    5 W415-0583 / D / 07.24.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . DO NOT SUB- STITUTE MA TERIALS. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace ...

  • Napoleon Fireplaces GD82PT-T - page 6

    6 W415-0583 / D / 07.24.07 VER TICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T ...

  • Napoleon Fireplaces GD82PT-T - page 7

    7 W415-0583 / D / 07.24.07 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H ...

  • Napoleon Fireplaces GD82PT-T - page 8

    8 W415-0583 / D / 07.24.07 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet See graph to ...

  • Napoleon Fireplaces GD82PT-T - page 9

    9 W415-0583 / D / 07.24.07 FIGURE 12 ...

  • Napoleon Fireplaces GD82PT-T - page 10

    10 W415-0583 / D / 07.24.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer . See Accessories to order the specifi c kit required. 1 . Determine the air terminal location, cut and frame 1 1½ inch openings in the ceiling and the roof to provide the minimum cl ...

  • Napoleon Fireplaces GD82PT-T - page 11

    11 W415-0583 / D / 07.24.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. (Fig.a) 3. Stretch the ...

  • Napoleon Fireplaces GD82PT-T - page 12

    12 W415-0583 / D / 07.24.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 3. Apply high tempera ...

  • Napoleon Fireplaces GD82PT-T - page 13

    13 W415-0583 / D / 07.24.07 FLUE COLLAR RESTRICTOR PLA TE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” ...

  • Napoleon Fireplaces GD82PT-T - page 14

    14 W415-0583 / D / 07.24.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. Do not distor t or force the fr ame kit components. W hen using a rough fi nish materi- al (i.e.; stone), maintain a ¼” - ½” bor der from the fr aming components. NON-COMBUSTIBLE FINISHING MA TERIAL 59 3 / 8 " 21 3 ...

  • Napoleon Fireplaces GD82PT-T - page 15

    15 W415-0583 / D / 07.24.07 FIGURE 32 MANTLE CLEARANCES 0 34 7 8 9 11 13 12 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part has been under water . Call a qualified service technician IMMED ...

  • Napoleon Fireplaces GD82PT-T - page 16

    16 W415-0583 / D / 07.24.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door . Next, pi ...

  • Napoleon Fireplaces GD82PT-T - page 17

    17 W415-0583 / D / 07.24.07 UNDERSIDE OF ROCK CLUSTER 3. Carefully place the rocks on the bowl by lining up the locating notch on the underside of the rock cluster with the opening in the rear of the bowl. (Fig. 39) FIGURE 37 FIGURE 38 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base. Once the gas has been disconnected, ...

  • Napoleon Fireplaces GD82PT-T - page 18

    18 W415-0583 / D / 07.24.07 3. Remove optional front, glass door , bowl w/ rocks, burner , decorative panel, & burner bottom. 4. The blower mounting plate can now be removed. Remove the four screws that secure the plate to the fi rebox base. 5. The blower is secured to the fi rebox. Disconnect the wire connectors before attempting to remove t ...

  • Napoleon Fireplaces GD82PT-T - page 19

    19 W415-0583 / D / 07.24.07 Yo u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below . Unplug the wire harness / transformer from the junction box inside the fi replace or turn off the electrical break ...

  • Napoleon Fireplaces GD82PT-T - page 20

    20 W415-0583 / D / 07.24.07 2. FLAME HEIGHT This function allows remote control of the fl ame height. Check that the Remote Control is on, otherwise, turn on the Remote Control and wait 5 seconds. Select the manual fl ame height until the cursor (small triangle) is to the left of the big fl ame. (Fig. 47) Use the RIGHT or LEFT button to set the ...

  • Napoleon Fireplaces GD82PT-T - page 21

    21 W415-0583 / D / 07.24.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu ...

  • Napoleon Fireplaces GD82PT-T - page 22

    22 W415-0583 / D / 07.24.07 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function. The transmitter address is required to be equal to ...

  • Napoleon Fireplaces GD82PT-T - page 23

    23 W415-0583 / D / 07.24.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57 ...

  • Napoleon Fireplaces GD82PT-T - page 24

    24 W415-0583 / D / 07.24.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control ...

  • Napoleon Fireplaces GD82PT-T - page 25

    25 W415-0583 / D / 07.24.07 FIGURE 60 Adjust the pilot screw to provide properly sized fl ame. T urn in a clockwise direction to reduce the gas fl ow . FIGURE 61 ADJUSTMENTS PILO T BURNER ADJUSTMENT TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE. CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiri ...

  • Napoleon Fireplaces GD82PT-T - page 26

    26 W415-0583 / D / 07.24.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly , a fi re, explosion or pro- duction ...

  • Napoleon Fireplaces GD82PT-T - page 27

    27 W415-0583 / D / 07.24.07 # P ART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBL Y 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LA TCH ( EA ) 7 W725-0047 NA TURAL GAS V AL VE - MODULA TING 7 W725-0048 PROP ANE GAS V AL VE - MODULA TING 8* W455-0019 NA TURAL GAS ORIFICE #43 8* W455-0003 PROP A ...

  • Napoleon Fireplaces GD82PT-T - page 28

    28 W415-0583 / D / 07.24.07 35 34 16 48 46 45 22 19 28 18 20 AUX ON 0:00 00 ON/OFF FEATURE SELECT 21 25 23 24 26 1 2 17 4 11 9 13 12 10 54 40 41 42 43 55 39 3 5 ...

  • Napoleon Fireplaces GD82PT-T - page 29

    29 W415-0583 / D / 07.24.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass, ...

  • Napoleon Fireplaces GD82PT-T - page 30

    30 W415-0583 / D / 07.24.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing. - check for ground (short); repair ground or replace wire. Remote wall switch wire is ground ...

  • Napoleon Fireplaces GD82PT-T - page 31

    31 W415-0583 / D / 07.24.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

  • Napoleon Fireplaces GD82PT-T - page 32

    32 W415-0583 / D / 07.24.07 NOTES ...

メーカー Napoleon Fireplaces カテゴリー Printer Accessories

Napoleon Fireplaces GD82PT-Tのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GD82PT-Tの取扱説明書
- Napoleon Fireplacesの製品カード
- パンフレット
- またはNapoleon Fireplaces GD82PT-Tの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napoleon Fireplaces GD82PT-Tの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napoleon Fireplaces GD82PT-Tの取り付け説明書、サービスマニュアル、簡易説明書、またはNapoleon Fireplaces GD82PT-Tのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napoleon Fireplaces GD82PT-Tの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Napoleon Fireplaces GD82PT-Tデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapoleon Fireplaces GD82PT-Tを使用するのを助ける技術的文書のことです。説明書は通常、全てのNapoleon Fireplaces GD82PT-Tユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napoleon Fireplacesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napoleon Fireplaces GD82PT-Tの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapoleon Fireplaces GD82PT-Tの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napoleon Fireplaces GD82PT-Tに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napoleon Fireplaces GD82PT-Tデバイスの基本機能を使うにあたってのヒント。 Napoleon Fireplaces GD82PT-Tのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napoleon Fireplaces GD82PT-Tに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapoleon Fireplaces GD82PT-Tのメーカー/サービスへの連絡先に関する情報。

Napoleon Fireplaces GD82PT-Tについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapoleon Fireplaces GD82PT-Tの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapoleon Fireplaces GD82PT-Tで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)