    WM 550-141-996/1 105 Page 1 RWB 6104WMNX R1005 Beckett Model NX Burner  Please read and follow all instructions on Page 3 in this manual regarding your responsibilities in caring for you r heating equipment Contact a qualified service agency for installation and start-up. Incorrect Installation, adjustment, or misuse of this burner could resu ...

  • Weil-McLain NX - page 2

    Page 2 WM 550-141-996/1 105 RWB 6104WMNX R1005 T able of Contents Hazard De fi nitions and Owner ’ s Information ........................................................................................ 3 Information T o Be Used Only By Quali fi ed Service T echnicians Weil McLain Burner Speci fi cation ......................................... ...

  • Weil-McLain NX - page 3

    WM 550-141-996/1 105 Page 3 RWB 6104WMNX R1005 T o the Owner: Thank you for purchasing a Beckett NX burner for use with your heating appliance. Please pay atten- tion to the Safety W arnings contained within this in- struction manual. Keep this manual for your records and provide it to your quali fi ed service agency for use in professionally sett ...

  • Weil-McLain NX - page 4

    Page 4 WM 550-141-996/1 105 RWB 6104WMNX R1005 V erify that burner speci fi cation number (on burner carton) and con fi guration agrees with information below . T able 1. Burner Con fi gurations The table below provides burner speci fi cations and starting air settings for NX burners applied to Weil-McLain Model UO boilers. Follow all instructi ...

  • Weil-McLain NX - page 5

    WM 550-141-996/1 105 Page 5 RWB 6104WMNX R1005 General Speci fi cations T able 2 – Burner Speci fi cations Capacity LB & LC Firing rate 0.40 – 1.35 GPH Input 56,000 – 189,000 Btu LD & LF Firing rate 1.10 - 1.75 GPH Input 154,000 – 245,000 Btu/h Fuels U. S No. 1 or No. 2 heating oil only ........... (ASTM D396) Canada No. 1 stove o ...

  • Weil-McLain NX - page 6

    Page 6 WM 550-141-996/1 105 RWB 6104WMNX R1005 Figure 1. Burner label location State and local approvals are shown on burner rat- ing label mounted on the burner housing. For recommended installation practice in Canada, refer to the latest version of CSA Standard B139 & B140. General Speci fi cations Notice Special Requirements Concealed damag ...

  • Weil-McLain NX - page 7

    WM 550-141-996/1 105 Page 7 RWB 6104WMNX R1005 Inspect/Prepare Installation Site Clearances to Burner and Appliance Provide space around burner and appliance for ease of service and maintenance. Check the minimum clearances against those shown by the appliance manufacturer and by ap- plicable building codes. Inspect Chimney or Direct V ent System I ...

  • Weil-McLain NX - page 8

    Page 8 WM 550-141-996/1 105 RWB 6104WMNX R1005 Fuel Line V alves and Filter Install two high quality oil duty rated shutoff valves in accessible locations on the oil supply line. Locate one close to the tank and the other close to the burner , upstream of the fi lter . Also install a generous capacity fi lter , rated for 50 microns or less, insid ...

  • Weil-McLain NX - page 9

    WM 550-141-996/1 105 Page 9 RWB 6104WMNX R1005 Warning – By-pass Plug in 2 Pipe System The burner pump is shipped without the by-pass plug installed. You must install this plug on two-pipe oil systems. If the unit is a one-pipe oil system DO NOT install the plug in the pump. Failure to comply could cause pump seal failure, oil leakage and the pot ...

  • Weil-McLain NX - page 10

    Page 10 WM 550-141-996/1 105 RWB 6104WMNX R1005 Figure 3. – Burner Connections. Bur ner Prepar ation SK9806 ...

  • Weil-McLain NX - page 11

    WM 550-141-996/1 105 Page 1 1 RWB 6104WMNX R1005 G R R BK W O V BL/W BURNER JUNCTION BO X BURNER PRIMAR Y CONTROL 3/T T CAD CELL IGNITOR SOLENOID VA LV E Y Y W W W LIMIT L1 L2 L2 L2 L2 VA LV E IGNITOR MOT OR W BK R7184P Primary ontrol C T 1 2 BE R MOT OR URN R BK W PRESSURE SWITCH (DIRECT VENT ONL Y) Burners with Beckett Clean Cut Pump must be used ...

  • Weil-McLain NX - page 12

    Page 12 WM 550-141-996/1 105 RWB 6104WMNX R1005 Start the Burner and Set Combustion Start-up and Initial Settings Open the shutoff valves in the oil supply line to the burner . Referencing Figure 5 verify and/or set the Head/ Air Adjustment Pointer to the value shown in T able 1. This is an initial air setting for the pump bleeding procedure only . ...

  • Weil-McLain NX - page 13

    WM 550-141-996/1 105 Page 13 RWB 6104WMNX R1005 Chimney V ent Systems: Install the burner cover and repeat Steps 2 and 4 above. If CO 2 increas- es (O 2 decreases), remove the cover and adjust the air setting so the CO 2 (O 2 ) with the cover installed meets the requirements of Step 3. Direct V ent Systems with Outside Air Ducted to Burner: Install ...

  • Weil-McLain NX - page 14

    Page 14 WM 550-141-996/1 105 RWB 6104WMNX R1005 Warning–Professional Service Required This equipment must be installed, adjusted and put into operation only by a qualified individual or service agency that is: x Licensed or certified to install and provide technical service to oil heating systems. x Experienced with all applicable codes, st ...

  • Weil-McLain NX - page 15

    WM 550-141-996/1 105 Page 15 RWB 6104WMNX R1005 Nozzle Installation Obtain a nozzle having the capacity , spray angle, and pattern speci fi ed in the appliance manufac- turer ’s information or Beckett OEM Speci fi cation Guide, Part # 671 1. Make certain the correct nozzle is selected for the actual fuel pump pressure. See T able 1. Perform the ...

  • Weil-McLain NX - page 16

    Page 16 WM 550-141-996/1 105 RWB 6104WMNX R1005 Check/Adjust Electrodes Check the electrode tip settings, as shown in Fig- ure 7. If necessary , adjust by loosening the elec- trode clamp screw (Figure 8) and slide/rotate the electrodes as necessary . When the adjustment is complete, securely tighten the clamp screw . Check Retention Head Alignment ...

  • Weil-McLain NX - page 17

    WM 550-141-996/1 105 Page 17 RWB 6104WMNX R1005 Professional Maintenance Blower Wheel Replacement For installation or replacement of a blower wheel, insure that there is a space between the blower wheel and the motor face of 0.1 15”. Refer to Figure 10. • Figure 10. – Blower wheel assembly SK9670 ...

  • Weil-McLain NX - page 18

    Page 18 WM 550-141-996/1 105 RWB 6104WMNX R1005 For best performance specify genuine Beckett replacement parts Replacement Parts Diagram Professional Maintenance SK967102 SK9803B SK9804B ...

  • Weil-McLain NX - page 19

    WM 550-141-996/1 105 Page 19 RWB 6104WMNX R1005 Item Description Part No. 1 Head/Air adjustment mecha- nism assembly 51794U 2 Air guide 101 101U 3 Gasket, mounting fl ange (not shown) 32389 4 Air tube combination, (Includes Screws, air tube mounting #8 x 3/8) Specify 4396 5 Blower wheel 2999U 6 Connector tube assembly , 1 1” 51 127 7 Coupling 24 ...

  • Weil-McLain NX - page 20

    Page 20 WM 550-141-996/1 105 RWB 6104WMNX R1005 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in mate ...

Fabricante Weil-McLain Categoría Burner

Los documentos del dispositivo Weil-McLain NX que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Weil-McLain
- manuales de instrucciones NX
- hojas de producto Weil-McLain
- folletos informativos
- o etiquetas energéticas Weil-McLain NX
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Weil-McLain NX.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Weil-McLain NX, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Weil-McLain NX. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Weil-McLain NX.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Weil-McLain NX, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Weil-McLain NX. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Weil-McLain NX.

El manual de instrucciones completo de Weil-McLain debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Weil-McLain NX - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Weil-McLain NX, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Weil-McLain NX que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Weil-McLain NX - que deben facilitarnos los primeros pasos durante el uso de Weil-McLain NX
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Weil-McLain NX
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Weil-McLain NX en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Weil-McLain NX?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Weil-McLain NX, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Weil-McLain NX probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)