Manual de instrucciones Waves EQ Sampling System Q-Clone

34 de páginas 2.1 mb
Descargar

Pasar a la página of 34

Summary
  • Waves EQ Sampling System Q-Clone - page 1

    W a v es Q-Clone EQ Sampling System Waves Q-Clone Manual 1 ...

  • Waves EQ Sampling System Q-Clone - page 2

    Introduction You own a great sounding hardware EQ. It sounds great. It feels good. You know just how to “tweak” the knobs to get the sound that you are looking for. But perhaps you can’t afford to buy 97 more hardware EQs for every one of the 98 tracks in your current mix! Even if you could, wouldn’t it be like a dream come true if you coul ...

  • Waves EQ Sampling System Q-Clone - page 3

    B EHIND THE S CENES The Q-Capture component sends a conti nuous test signal (routed to the audio card output) to the i nput of the EQ-device that is being cloned. Only a fraction of a second later, the output of that device (routed to the audio card input) is returned to the input of the Q-Capture component. Waves Q-Clone Manual 3 Diagram 1 ...

  • Waves EQ Sampling System Q-Clone - page 4

    Once the test-signal returns from the dev ice, it is analyzed and loaded into the Q- Clone component as an impulse-response. This happens several times per second so that the EQ-settings of the dev ice are well tracked by the cloned EQ. As long as the Q-Clone is in ‘Capture’ m ode, it keeps on tracking the EQ-settings of the device. When the Q- ...

  • Waves EQ Sampling System Q-Clone - page 5

    Q-Capture Component The Q-capture sends a test signal from it s output that is intended to be fed back into its own input through the EQ-device. It should be opened on a live I/O. This can be a Mono Auxiliary tra ck or an Audio Track, depending on your Audio host. Only a single instance of Q-C apture can work at a time. T HE T RANSMITTING S ECTION ...

  • Waves EQ Sampling System Q-Clone - page 6

    The Receiving section also shows an input meter to indicate the signal level returning from your EQ device, back into the channel. C ALIBRATION S ECTION – The Headroom slider and t he In and Out meters are on the right side of the Q-Capture. These not only indicate that signal is being received, but can also help to adjust t he Headroom fader of ...

  • Waves EQ Sampling System Q-Clone - page 7

    Q-Clone Component The Q-Clone plug-in has 2 main controls - Gain and Mode. It also has a Scale control for the frequency response graph. The Mode control shows: Capt ure, Hold and Add. C APTURE – Capture sets the plug-in to adapt it s filter purely to the settings in the cloned EQ device. This mode can only wo rk when the Q-Capture component is a ...

  • Waves EQ Sampling System Q-Clone - page 8

    Clone, except that the ov erall EQ will be shown in a single graph a nd the CPU usage will be that of on ly a single instance. Please note that to switch from Captur e to Add Mode, or vice-versa, you must first go through Hold mode. F REQUENCY R ESPONSE G RAPH The larger part of the Q-Clone GU I shows a frequency response graph. It has a logarithmi ...

  • Waves EQ Sampling System Q-Clone - page 9

    When a Q-Clone instance is launched it will load in Hold mo de with a flat EQ response. When you switch to the Captur e or Add modes it will check for a port to receive the EQ filter transmission. If it does not find such a port it will show a text message stating – “No Transmission!” If the Transmission signal is too low for sampling an EQ p ...

  • Waves EQ Sampling System Q-Clone - page 10

    L OAD will replace any existing sampled EQ with the one in the preset. A DD will load the preset on top of the current EQ settings. Since the Q-Clone's preset files include t he complete EQ filter, and there is no need for external media files, it is very easy to share EQ settings. Now, if you have a favorite EQ in your home studio in Atlanta, ...

  • Waves EQ Sampling System Q-Clone - page 11

    C ALIBRATING : In this section we will learn how to calib rate the Q-Clone with our Hardware EQ in order to achieve the best cloning results. First, we should ex plain “Headroom”. Every electronic channel, digital or analog, has a maximum signal level that it can pass. Attempting to exceed this typicall y results in hard clipping, where the wav ...

  • Waves EQ Sampling System Q-Clone - page 12

    If the set up is not working properly, y ou will see the word “Waiting” in one or both parts of the GUI. Th is can happen when the physical loop between your audio host, audio card and EQ hardware devic e is not complete. You would also get the "Waiting" message if the I/O on t he Audio/AUX channel is not assigned to the correct I/O o ...

  • Waves EQ Sampling System Q-Clone - page 13

    Quick Start up and Set up: Here are basic, step by step directions on how to prepare your session to use the Q-Clone and clone your EQ device for various Host Applications: Pro-tools 6.7 LE and TDM: 1. Connect a cable from one of your audio card output ports into the input of the EQ device. 2. Connect a cable from t he output of the EQ device to yo ...

  • Waves EQ Sampling System Q-Clone - page 14

    8. Open the Q-Capture on this AUX track and make su re that this is the only plug-in that you have on this track’s plug-in list. 9. Calibrate the Q-Capture with your EQ device as instructed in the Calibration section on page 11. 10. Go to your Audio track (where you want to use the cloned set-up of your EQ device) and open the Q-Clone on its inse ...

  • Waves EQ Sampling System Q-Clone - page 15

    C. Reset – Reset the preset by loading t he “reset preset” file from the Load menu. D. Add on top – By clicking the “Add” button you can load a new preset on top of an existing one. The “Add” mode gives the effect of having 2 or more EQ devices in a chain. There are 2 options for Add mode: i. Open a Q-clone preset (from the Q-Clone ...

  • Waves EQ Sampling System Q-Clone - page 16

    7. Set the I/O of this track to match the in sert I/O that you used in steps 1 & 2. The basic I/O setting can be done from the Nuendo/Cubase Menu Bar under Devices>VST Connections (as seen in the follo wing pictures). Waves Q-Clone Manual 16 ...

  • Waves EQ Sampling System Q-Clone - page 17

    Waves Q-Clone Manual 17 ...

  • Waves EQ Sampling System Q-Clone - page 18

    8. Put the Q-Capture in the first N uendo/Cubase Insert slot. It will be located in the Waves Plug-In list. Waves Q-Clone Manual 18 ...

  • Waves EQ Sampling System Q-Clone - page 19

    9. Arm the monitor (push the m onitor button) on this track 10. Calibrate your EQ har dware with the Q-Capture following the directions on the Calibration chapter on page 11. 11. On the audio track that you want to process, open the Q- Clone in the insert channel of that track. It will be located in the Waves Plug-In list. 12. Make sure that the I/ ...

  • Waves EQ Sampling System Q-Clone - page 20

    13. When the Q-Clone is opened it will be in “Hold” mode. When you switch the “Capture” on, it will be able to star t receiving the cloning image from the EQ device. Once this happens, you wil l see the red line on your display graph showing your pr esent EQ curve. 14. Play this track (solo it or play it with the entire sessi on) and start ...

  • Waves EQ Sampling System Q-Clone - page 21

    D. Add – By clicking the “Add” button you can load a new preset on top of an existing one. T he “Add” mode gives the ef fect of having 2 or more EQ devices in a chain. There are 2 options for Add mode: i. Open a Q-clone preset (from the Q-Clone preset menu or any directory on your hard drive) or use the existing displayed EQ curve. Click ...

  • Waves EQ Sampling System Q-Clone - page 22

    7. Arm the “Record” button and the “I nput Echo” button. (Click them on.) 8. Calibrate the Q-Capture with your EQ device as instructed in the Calibration section on page 11. 9. On an Audio track (the one that you want to process) insert the Q- Clone (Mono or Stereo, according to the track). You must bypass all other plug-ins on the track wh ...

  • Waves EQ Sampling System Q-Clone - page 23

    New File” . This saves a preset file to any desired directory on your computer. B. Save your EQ to your Waves Preset Menu - Click the “Save” button on the Waves menu bar and choose “Put Into Preset Menu As…” This will allow you to load your new preset anytime you open the Waves Q-Clone preset menu. C. Reset – Reset the preset by loadi ...

  • Waves EQ Sampling System Q-Clone - page 24

    6. Open your Logic sessi on and open a new Audio file (which will be dedicated to the Q-Capture ). 7. On this track, assign the input of the channel to the input of your audio card that receives the hardware output cable ( input Y ). 8. Also on this track assign the output of the channel to t he output of your audio card that receives the hardware ...

  • Waves EQ Sampling System Q-Clone - page 25

    10. Calibrate the Q-Capture with your EQ device as instructed in the Calibration chapter on page 11 . 11. On an Audio track (the one that you want to process) insert the Q- Clone (Mono or Stereo, according to the track). You must bypass all other plug-ins on the track while you are “EQ-ing” it. 12. When the Q-Clone is open, click the Capture bu ...

  • Waves EQ Sampling System Q-Clone - page 26

    D. Add – By clicking the “Add” button you can load a new preset on top of an existing one. The “Add” mode gives the effect of having 2 or more EQ devices in a chain. There are 2 options for Add mode: i. Open a Q-clone preset (from t he Q-Clone preset menu or any directory on your hard dr ive) or use the existing displayed EQ curve. Click ...

  • Waves EQ Sampling System Q-Clone - page 27

    B. “Setup” menu, choose “Configure Audio Syste m” and choose the “Input Monitoring Mode…” Waves Q-Clone Manual 27 ...

  • Waves EQ Sampling System Q-Clone - page 28

    In this dialog box check the “Always” option and click OK. 6. Open your DP session and open a new Audio file (which will be dedicated to the Q-Capture ). 7. On this dedicated track, assign t he input of the channel to the audio card input that is connected to the hardware output cable ( input Y ). 8. Also on this dedicated track, a ssign the ou ...

  • Waves EQ Sampling System Q-Clone - page 29

    11. Calibrate the Q-Capture with your EQ device as instructed in the Calibration section on page 11. 12. On an Audio track (the one that y ou want to process) insert the Q- Clone (Mono or Stereo, according to the track). You must bypass all other plug-ins on the track while you are “EQ-ing” it. 13. When the Q-Clone is open, click the Capture bu ...

  • Waves EQ Sampling System Q-Clone - page 30

    Waves Q-Clone Manual 30 c. Reset – Reset the preset by loading t he reset preset file from the Load menu. d. Add – By clicking the “Add” button you can load a new preset on top of an existing one. The “Add” mode gives the effect of having 2 or more EQ devices in a chain. There are 2 options for Add mode: i. Open a Q-clone preset (from t ...

  • Waves EQ Sampling System Q-Clone - page 31

    Waves Q-Clone Manual 31 maximum capacity, the real time tasks have dropouts which result in flashing “No Transmission” messages. 7. Sonar will have a boost in the returned Capture signal. This can be fixed by applying digital corrective gain be fore the Q-Capture plug-in. Q-C LONE L OOP C HECKLIST : 1. Connect the EQ hardware device to the Soun ...

  • Waves EQ Sampling System Q-Clone - page 32

    Waves Q-Clone Manual 32 Q-C LONE T ROUBLESHOOTING C HECK L IST : Problem Synopsis Action I’m capturing a flat device setting but the curve in the Q-Clone is not flat - Curve is smooth but not flat. This is probably representing the current state of your analog system. - Curve is drastically unfelt and/or full of ripples. - Try closing the loop in ...

  • Waves EQ Sampling System Q-Clone - page 33

    Waves Q-Clone Manual 33 Q-Clone shows “No Transmission” on the frequency response display. - Q-Capture is not well routed, is in bypass or disabled. - Signal is very low. - Make sure Q-Capture meters show “Transmitting” and “Receiving” messages. - Check your analog connections. EQ Curve in the frequency response display does not seem sm ...

  • Waves EQ Sampling System Q-Clone - page 34

    Waves Q-Clone Manual 34 ...

Fabricante Waves Categoría Stereo Equalizer

Los documentos del dispositivo Waves EQ Sampling System Q-Clone que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Waves
- manuales de instrucciones EQ Sampling System Q-Clone
- hojas de producto Waves
- folletos informativos
- o etiquetas energéticas Waves EQ Sampling System Q-Clone
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Waves EQ Sampling System Q-Clone.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Waves EQ Sampling System Q-Clone, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Waves EQ Sampling System Q-Clone. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Waves EQ Sampling System Q-Clone.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Waves EQ Sampling System Q-Clone, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Waves EQ Sampling System Q-Clone. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Waves EQ Sampling System Q-Clone.

El manual de instrucciones completo de Waves debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Waves EQ Sampling System Q-Clone - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Waves EQ Sampling System Q-Clone, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Waves EQ Sampling System Q-Clone que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Waves EQ Sampling System Q-Clone - que deben facilitarnos los primeros pasos durante el uso de Waves EQ Sampling System Q-Clone
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Waves EQ Sampling System Q-Clone
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Waves EQ Sampling System Q-Clone en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Waves EQ Sampling System Q-Clone?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Waves EQ Sampling System Q-Clone, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Waves EQ Sampling System Q-Clone probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)