Manual de instrucciones Omega IP710 SERIES

12 de páginas 0.37 mb
Descargar

Pasar a la página of 12

Summary
  • Omega IP710 SERIES - page 1

    U ser ’ s Guide IP710 SERIES I/P Conver ters Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info ...

  • Omega IP710 SERIES - page 2

    Servicing Nor th America: USA: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: S ...

  • Omega IP710 SERIES - page 3

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m d ate of pu rcha se. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s c ...

  • Omega IP710 SERIES - page 4

    Page 1 1 .00 25.4 2.94 74.7 1 2 3.69 93.7 2.18 55.4 .125 3.17 .500 12.7 1.80 45.7 1.30 33.0 1.50 38.1 Mounting Holes #10 –32 UNF –2B X 3/8 Deep 2 Places 22 GA. wire leads approx. 18" long pos, neg, grd In and out ports 1/4 –20 NPT 4 places 1.13 28.7 3.12 79.2 .516 13.1 .383 9.72 ...

  • Omega IP710 SERIES - page 5

    DANGER, W ARNING, CAUTION and NOTE statements R efers to conditions or hazards which could result in serious personal injury or death. Refers to conditions or hazards which could result in personal injury . Refers to conditions or hazards which could result in equipment or proper ty damage. Alerts you to facts or special instructions. ALL DANGER, W ...

  • Omega IP710 SERIES - page 6

    1. DESCRIPTION and INST ALLA TION 1.1 Description 1.1.1 The Omega IP710 converts a curr ent input signal to a linearly proportional pneumatic output pressur e. This unit utilizes a closed loop pressur e feedback system that closely controls output and compensates for vibration, mounting angle, temperature and supply pr essure variations. The contr ...

  • Omega IP710 SERIES - page 7

    Figure 3 - DIN 43650 Connector DIN Rail mounting kit IP610-DM 1.4 Pneumatic Connections 1.4.1 Clean all pipe lines to remove dirt and scale befor e installation. 1.4.2 Supply air must be filtered to 40 micr ons and free of moistur e and lubricants. 1.4.3 The 1/4” NPT inlet and outlet connections ar e labeled on the body . Plug all unused ports wi ...

  • Omega IP710 SERIES - page 8

    1.6 Factory Mutual Research Corporation (FM) and Canadian Standards association (CSA) Factory Mutual and Canadian Standards Association I.S. Installation Drawing Notes: 1. Control equipment connected to the Associated Apparatus must not use or generate mor e than 250 V rms or Vdc. 2. The IS Barriers or Equipment (Associated Apparatus) must be FM Ap ...

  • Omega IP710 SERIES - page 9

    2. OPERA TION 2.1 Calibration 2.1.1 All units ar e shipped from the factory calibrated, direct acting. 2 .1.2 If the user r equires a differ ent mode of operation (i.e. reverse acting, split range) it is necessary to r eposition inter- n al electrical switches as indicated below . Though the units are factory calibrated for direct acting it is sugg ...

  • Omega IP710 SERIES - page 10

    2.3 Reverse Acting Calibration 2.3.1 When calibrated to operate in the r everse acting mode the minimum input signal produces the maximum output pressur e and increasing the input signal r esults in decreasing the output pressur e. Setting the unit to operate in the reverse acting mode is accomplished by positioning internal electrical switches. Do ...

  • Omega IP710 SERIES - page 11

    Page 8 3. MAINTENANCE AND REP AIRS U nder normal circumstances, no maintenance should be required. 3.1 Cleaning 3.1.1 If clean, dry air is not used the orifice can become blocked. T o clear , first tur n off supply air , then remove the screw located under the zer o adjustment. The orifice is located between the two black o-rings. Y ou may need a m ...

  • Omega IP710 SERIES - page 12

    M-4063/ 0 3 0 7 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE M U Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies M U W ire: Thermocouple, R TD & Thermistor M U Calibrators & Ice Point References M U Recorders, Contr ol ...

Fabricante Omega Categoría TV Converter Box

Los documentos del dispositivo Omega IP710 SERIES que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega
- manuales de instrucciones IP710 SERIES
- hojas de producto Omega
- folletos informativos
- o etiquetas energéticas Omega IP710 SERIES
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega IP710 SERIES.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega IP710 SERIES, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega IP710 SERIES. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega IP710 SERIES.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega IP710 SERIES, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega IP710 SERIES. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega IP710 SERIES.

El manual de instrucciones completo de Omega debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega IP710 SERIES - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega IP710 SERIES, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega IP710 SERIES que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega IP710 SERIES - que deben facilitarnos los primeros pasos durante el uso de Omega IP710 SERIES
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega IP710 SERIES
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega IP710 SERIES en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega IP710 SERIES?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega IP710 SERIES, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega IP710 SERIES probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)