  • Omega IP710 SERIES - page 1

    U ser ’ s Guide IP710 SERIES I/P Conver ters Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info ...

  • Omega IP710 SERIES - page 2

    Servicing Nor th America: USA: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: S ...

  • Omega IP710 SERIES - page 3

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m d ate of pu rcha se. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s c ...

  • Omega IP710 SERIES - page 4

    Page 1 1 .00 25.4 2.94 74.7 1 2 3.69 93.7 2.18 55.4 .125 3.17 .500 12.7 1.80 45.7 1.30 33.0 1.50 38.1 Mounting Holes #10 –32 UNF –2B X 3/8 Deep 2 Places 22 GA. wire leads approx. 18" long pos, neg, grd In and out ports 1/4 –20 NPT 4 places 1.13 28.7 3.12 79.2 .516 13.1 .383 9.72 ...

  • Omega IP710 SERIES - page 5

    DANGER, W ARNING, CAUTION and NOTE statements R efers to conditions or hazards which could result in serious personal injury or death. Refers to conditions or hazards which could result in personal injury . Refers to conditions or hazards which could result in equipment or proper ty damage. Alerts you to facts or special instructions. ALL DANGER, W ...

  • Omega IP710 SERIES - page 6

    1. DESCRIPTION and INST ALLA TION 1.1 Description 1.1.1 The Omega IP710 converts a curr ent input signal to a linearly proportional pneumatic output pressur e. This unit utilizes a closed loop pressur e feedback system that closely controls output and compensates for vibration, mounting angle, temperature and supply pr essure variations. The contr ...

  • Omega IP710 SERIES - page 7

    Figure 3 - DIN 43650 Connector DIN Rail mounting kit IP610-DM 1.4 Pneumatic Connections 1.4.1 Clean all pipe lines to remove dirt and scale befor e installation. 1.4.2 Supply air must be filtered to 40 micr ons and free of moistur e and lubricants. 1.4.3 The 1/4” NPT inlet and outlet connections ar e labeled on the body . Plug all unused ports wi ...

  • Omega IP710 SERIES - page 8

    1.6 Factory Mutual Research Corporation (FM) and Canadian Standards association (CSA) Factory Mutual and Canadian Standards Association I.S. Installation Drawing Notes: 1. Control equipment connected to the Associated Apparatus must not use or generate mor e than 250 V rms or Vdc. 2. The IS Barriers or Equipment (Associated Apparatus) must be FM Ap ...

  • Omega IP710 SERIES - page 9

    2. OPERA TION 2.1 Calibration 2.1.1 All units ar e shipped from the factory calibrated, direct acting. 2 .1.2 If the user r equires a differ ent mode of operation (i.e. reverse acting, split range) it is necessary to r eposition inter- n al electrical switches as indicated below . Though the units are factory calibrated for direct acting it is sugg ...

  • Omega IP710 SERIES - page 10

    2.3 Reverse Acting Calibration 2.3.1 When calibrated to operate in the r everse acting mode the minimum input signal produces the maximum output pressur e and increasing the input signal r esults in decreasing the output pressur e. Setting the unit to operate in the reverse acting mode is accomplished by positioning internal electrical switches. Do ...

  • Omega IP710 SERIES - page 11

    Page 8 3. MAINTENANCE AND REP AIRS U nder normal circumstances, no maintenance should be required. 3.1 Cleaning 3.1.1 If clean, dry air is not used the orifice can become blocked. T o clear , first tur n off supply air , then remove the screw located under the zer o adjustment. The orifice is located between the two black o-rings. Y ou may need a m ...

  • Omega IP710 SERIES - page 12

    M-4063/ 0 3 0 7 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE M U Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies M U W ire: Thermocouple, R TD & Thermistor M U Calibrators & Ice Point References M U Recorders, Contr ol ...

メーカー Omega カテゴリー TV Converter Box

Omega IP710 SERIESのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IP710 SERIESの取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega IP710 SERIESの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega IP710 SERIESの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega IP710 SERIESの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega IP710 SERIESのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega IP710 SERIESの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega IP710 SERIESデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega IP710 SERIESを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega IP710 SERIESユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega IP710 SERIESの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega IP710 SERIESの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega IP710 SERIESに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega IP710 SERIESデバイスの基本機能を使うにあたってのヒント。 Omega IP710 SERIESのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega IP710 SERIESに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega IP710 SERIESのメーカー/サービスへの連絡先に関する情報。

Omega IP710 SERIESについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega IP710 SERIESの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega IP710 SERIESで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)