  • Goodman Mfg R-410A - page 1

    GPC 14 SEER R-410A Package Air Conditioners with R-410A Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322007r2 August 2009 **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax pro ...

  • Goodman Mfg R-410A - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodman Mfg R-410A - page 3

    PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPC1424H41A* GPC1430H41A* GPC1436H41A* GPC1442H41A* GPC1448H41A* GPC1460H41A* The United States Environmental Protection Agency (“EPA”) ...

  • Goodman Mfg R-410A - page 4

    4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions. The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended. A return air filter must be inst ...

  • Goodman Mfg R-410A - page 5

    PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- vice person with rails or guards i ...

  • Goodman Mfg R-410A - page 6

    6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du ...

  • Goodman Mfg R-410A - page 7

    PRODUCT DIMENSIONS 7 GPC14[24-60]H41A* Ch ass i s M o d el A B GPC 142 4 33 3 0½ GPC 143 0 33 3 0½ GPC 143 6 33 3 5½ GPC 144 2 33 3 5½ GPC 144 8 33 3 8½ GPC 146 0 33 3 8½ Dime n s ion s in i n c he s La rge Sm a l l Me d i u m 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T OPEN I NGS) A 14 . 0 00 B ...

  • Goodman Mfg R-410A - page 8

    P ACKAGE COOLING SPECIFICA TIONS 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg R-410A - page 9

    P ACKAGE COOLING SPECIFICA TIONS 9 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg R-410A - page 10

    ACCESSORIES 10 P a r t N um b er De s c r i p t io n O T18- 60 A O utdoor Ther mosta t Kit w/Loc k out S ta t O T/EHR 18-60 Eme rgenc y Heat R el ay K i t HK R E lec tr i c Heat K i t PCCP101- 1 03 Roo f Cur b PCP101- 103 Down flow Pl enum Ki t PCP101- 103R 8 Dow nflow Pl enum Ki t w / R - 8 I ns u lati on PCEC101- 1 03 Dow nflow Ec onomi zer for G ...

  • Goodman Mfg R-410A - page 11

    BLOWER PERFORMANCE DA T A 11 Dry Coil Data GPC14[24-60]H41A* 0. 1 0 .2 0 .3 0 .4 0 .5 0 .6 0 . 7 0 .8 C F M 9 34 75 9 75 5 63 8 58 1 4 8 9 - - W A T T S 9 57 77 67 38 39 0 - - C F M 9 90 83 7 80 1 74 4 69 6 6 5 2 6 0 1 - W ATT S 1 07 9 4 10 5 11 0 1 1 9 1 3 3 14 2 - C F M 106 1 9 89 9 47 9 25 8 76 - - - W ATT S 1 26 1 3 4 14 6 15 8 16 9 - - - C F M ...

  • Goodman Mfg R-410A - page 12

    12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P UT B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C F M FORMULA S BTU OUTPUT = CFM x 1.08 x RISE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodman Mfg R-410A - page 13

    13 COOLING PERFORMANCE DA T A GPC1424H41A* MOD E L : G P C 1424H41A * EX PAN DE D P ER FO R MANC E D ATA C OOL I NG OP E R AT I ON De s ign Sub c ooli ng , 9 ± 2°F @ the l i qui d a c c e s s fitting c onn e ct i on A HRI 9 5 te s t c ondi t io ns . Desi gn S upe r he at 5 ± 2 °F @ the c om pr es sor s uct i o n a cce ss fi tti n g co n nect io ...

  • Goodman Mfg R-410A - page 14

    14 COOLING PERFORMANCE DA T A GPC1424H41A* MOD E L : G PC 1424H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 9 ± 2°F @ the l i qui d acce s s f i tting c onn e ct i on A HRI 9 5 te s t c ondi t i ons . De s i gn S upe r he at 5 ± 2 °F @ the c om pr es sor s u cti on a cce ss fi t ti ng co n nect ...

  • Goodman Mfg R-410A - page 15

    15 COOLING PERFORMANCE DA T A GPC1430H41A* MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn S ubc ooli ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onnec tion A RI 9 5 test c ondi tio ns . De s i g n S up e rh e at 1 0 ± 2 °F @ the c o m p r es sor sucti o n acc ess f itt i n g co n n e ...

  • Goodman Mfg R-410A - page 16

    16 COOLING PERFORMANCE DA T A GPC1430H41A* MOD E L : G PC 1430H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s ign S ubc ool i ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onne ct i on A R I 9 5 t e st conditio ns . De s i g n Sup e rh e at 1 0 ± 2 °F @ the c o m p r es so r suct i o n acc ess f itt i n g c ...

  • Goodman Mfg R-410A - page 17

    17 COOLING PERFORMANCE DA T A GPC1436H41A* MOD E L : G P C 1436H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st c onditi ons. De s i gn S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n . ...

  • Goodman Mfg R-410A - page 18

    18 COOLING PERFORMANCE DA T A GPC1436H41A* MOD E L : G PC 1436H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st cond i tions. De sign S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n ...

  • Goodman Mfg R-410A - page 19

    19 COOLING PERFORMANCE DA T A GPC1442H41A* MOD E L : G P C 1442H 41A * EX PAN DE D P ER FO R M ANC E D AT A C OOLI NG OP E R ATION Desi g n Su b co o l i n g , 8 ± 2 ° F @ th e l i q u i d acc ess f it ti ng co n n e cti o n A H R I 9 5 test c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m p re sso r su ct io n ac ces s fi t ...

  • Goodman Mfg R-410A - page 20

    20 COOLING PERFORMANCE DA T A GPC1442H41A* MOD E L : G PC 1442H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON Desi g n Su b co o l i n g, 8 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e ct i o n A HR I 9 5 t est c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m pr e s s or suc t i on acce s s f ...

  • Goodman Mfg R-410A - page 21

    21 COOLING PERFORMANCE DA T A GPC1448H41A* MOD E L : G P C 1448H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d a c ce s s f i tting c onne c tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he at 1 0 ± 2 °F @ t he c ompr e ss or suc tion ac c es s fi t ti n g c onne c t ...

  • Goodman Mfg R-410A - page 22

    22 COOLING PERFORMANCE DA T A GPC1448H41A* MOD E L : G PC 1448H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d acce s s f i tting c onnec tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he a t 10 ± 2 ° F @ t he c o mpr e ss or suc tion a c c e s s fi t tin g c onne ...

  • Goodman Mfg R-410A - page 23

    23 COOLING PERFORMANCE DA T A GPC1460H41A* MOD E L : G P C 1460H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON Desi g n Su b co o l i n g, 6 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e cti o n A H R I 9 5 t est c on d i t i o n s. D esi g n Su p er h ea t 9 ± 2° F @ th e co m p re s s or s uct io n a cc e s s fit t ...

  • Goodman Mfg R-410A - page 24

    24 COOLING PERFORMANCE DA T A GPC1460H41A* MOD E L : G PC 1460H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 6 ± 2 °F @ the l i quid ac c es s fi t t i n g co nne c tion AH RI 9 5 t e s t c ond iti ons. De sign S upe r hea t 9 ± 2 °F @ the c ompre s s or sucti o n a c ce s s f itting c onne c ti ...

  • Goodman Mfg R-410A - page 25

    25 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...

  • Goodman Mfg R-410A - page 26

    26 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE POWE R S OUR CES MAY B E PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPC14[24-60]H41A* ...

Fabricante Goodman Mfg Categoría Air Conditioner

Los documentos del dispositivo Goodman Mfg R-410A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Goodman Mfg
- manuales de instrucciones R-410A
- hojas de producto Goodman Mfg
- folletos informativos
- o etiquetas energéticas Goodman Mfg R-410A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Goodman Mfg R-410A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Goodman Mfg R-410A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Goodman Mfg R-410A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Goodman Mfg R-410A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Goodman Mfg R-410A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Goodman Mfg R-410A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Goodman Mfg R-410A.

El manual de instrucciones completo de Goodman Mfg debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Goodman Mfg R-410A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Goodman Mfg R-410A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Goodman Mfg R-410A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Goodman Mfg R-410A - que deben facilitarnos los primeros pasos durante el uso de Goodman Mfg R-410A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Goodman Mfg R-410A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Goodman Mfg R-410A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Goodman Mfg R-410A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Goodman Mfg R-410A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Goodman Mfg R-410A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)