  • Omega DP3001 - page 1

    http://www.omega.com e-mail: info@omega.com ™ ® U ser’s Guide DP3001 DIGITAL PANEL VOLTMETER ...

  • Omega DP3001 - page 2

    ...

  • Omega DP3001 - page 3

    i TABLE OF CONTENTS SAFETY CONSIDERATIONS ......................................................................................... iii 1.0 GENERAL INFORMATION ........................................................................................ 1 2.0 SPECIFICATIONS ................................................................................ ...

  • Omega DP3001 - page 4

    ii LIST OF FIGURES: Figure 3.1 DIN Case Dimensions .................................................................................. 4 Figure 3.2 Exploded View .............................................................................................. 5 Figure 4.1 Side View of Transformer ........................................................ ...

  • Omega DP3001 - page 5

    iii SAFETY CONSIDERATIONS This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility). Unpacking & Inspection Unpack the instrument and inspect for obvious shipping d ...

  • Omega DP3001 - page 6

    ...

  • Omega DP3001 - page 7

    1 1.0 GENERAL INFORM AT I ON This voltmeter is a 4 1/2 digit panel meter f or applications which require a compact, quality DC v oltmeter . This model uses dual-slope conversion. Additionally , it provides automatic z eroing before each reading and does so with a minimum of par ts f or increased reliability . The voltmeter has a resolution of 1 par ...

  • Omega DP3001 - page 8

    2 2.4 A CCURA CY A T 25°C Maximum error ±0.01% of reading ±2 counts Span tempco ±0.01% of reading/°C Step response 1 second W ar m-up to rated accuracy 10 minutes 2.5 DIGIT AL INPUTS P ositive true referenced to DIG GND 2.6 ANALOG-T O-DIGIT AL CONVERSION T echnique Dual-slope, av erage-v alue Input integration period 100 milliseconds Read rate ...

  • Omega DP3001 - page 9

    3 2.10 MECHANICAL Bezel 96 x 48 x 5.1 mm (3.78 x 1.89 x 0.20 in) Depth behind bezel 104 mm (4.09 in) (with connector) P anel cutout 92 x 45 mm (3.62 x 1.77 in) W eight 400 g (14 oz) Case material 94V -0 UL-rated polycarbonate D1 connector option PCB edge connector with a double ro w of (non-CE) 18-pins, 3.96 mm (0.156 in) spacing between pin s D4 c ...

  • Omega DP3001 - page 10

    4 Figure 3.2 Exploded View 3.2 P ANEL MOUNTING 1. Remo ve main board connector J1, if installed. Loosen the two clamp screws (with a #8 Phillips screwdriv er) on the rear of case and rotate the slide clamps. Push the two slide retainers to ward the rear of the unit and remov e them. 2. W orking from the front of the panel, inser t the meter into th ...

  • Omega DP3001 - page 11

    5 4.0 POWER AND SIGNAL A C versions of the v oltmeter are factory-set for 115 V ac in the USA and 230 V ac in Europe (using C1 option) ±15% operation. DC versions are preset f or 9-32 Vdc or 26-56 Vdc operation. It is not possible to change the meter from 9-32 Vdc to 26-56 Vdc or vice versa. Different static in verters are installed by the f actor ...

  • Omega DP3001 - page 12

    6 Figure 4.2 Rear T erminal Hookups Wire Color for A C P ower USA Other (High) Black Brown (Low) White Blue (Ground) Green Green Model P ower Signal AC D1 Connector A High 17 High 2 Low 16 L ow C Ear th Ground T Analog Ground D4 Connector 1 High 6 High 2 Low 5 L ow 3 Ear th Ground 4 Analog Ground DC D1 Connector 2 + DC 17 High C - DC (return) 16 L ...

  • Omega DP3001 - page 13

    7 4.3 MAIN BO ARD PIN ASSIGNMENTS (J1 Card Edge) Left to right, looking at rear of case P1 Connection Standard A Spare (E16) 1 No connection B No connection 2 Spare (E18) C Spare (E19) 3 No connection D No connection 4 No connection E Spare (E43) 5 No connection F 1999.9 (DP4) 6 Spare (E24) H 199.99 (DP3) 7 Spare (E23) J 19.999 (DP2) 8 Spare (E22) ...

  • Omega DP3001 - page 14

    8 4.4 SIGNAL INPUTS RA TIO : The reference input allo ws an external voltage to be used as the ref erence source for con version. In this mode, the meter reads the r atio of the signal voltage to the ref erence voltage rather than the true v alue of the input. Signal V oltage Reading in Counts = Ref erence V oltage x 10000 On the 20 V and 200 V ran ...

  • Omega DP3001 - page 15

    9 5.0 CO NFIGURA TION Select the desired configurations from the f ollowing char ts. Install jumpers and open/close solder s witches as indicated. Remov e all push-on jumpers not used. 5.1 DECIMAL POINT SELECTION Figure 5.1 Display Boar d Jumper Locations Decimal P oint S1 Alternate decimal point configuration using main board connector J1. 1.999 ...

  • Omega DP3001 - page 16

    10 5.2 V OL T A GE RANGE SELECTION Figure 5.2 Main Board J umper Locations *Ref er to Figure 5.3 . S3-A is used f or signal connections. Refer to Section 4 f or more information. Input Configuration Solder Switches* Push-on Jumpers Wire Jumper Open Close S2 S4 W10 2 Vdc J, L H, I, K - - Install 20 Vdc J, L H, I, K A B Remove 200 Vdc J, L H, I, K A ...

  • Omega DP3001 - page 17

    11 Figure 5.3 Solder Switch Locations Solder s witch F is used for ref erence input impedance ratio . Ref er to Section 4 for more inf or mation. 6.0 C ALIBRA TION This unit was f actor y-calibrated with a precision v oltage source. F requent calibration is not necessary due to the stability and inter nal accuracy . If calibration is needed, use th ...

  • Omega DP3001 - page 18

    12 7.0 DRA WINGS Figure 7.1 Assembly Dia gram, Main and Display Board ...

  • Omega DP3001 - page 19

    13 8.0 D UAL-SLOPE CONVERSION At the beginning of a conv ersion, the voltage across C int is z ero . The signal is then applied to the integrator and the v oltage across C int rises by the f or mula: T1 E Cint = Esig R int C int At the end of a fix ed per iod of 10000 counts, T1, the counters are reset to 00000. The signal input is turned off and ...

  • Omega DP3001 - page 20

    NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ____________________________ ...

  • Omega DP3001 - page 21

    15 NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________ ...

  • Omega DP3001 - page 22

    16 NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________ ...

  • Omega DP3001 - page 23

    WARRANTY / DISCLAIMER OMEGA EN GINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineer ing will extend the warranty period for one (1) additional year if the warranty card enclosed with each instru ...

  • Omega DP3001 - page 24

    M5280/1112 11119ML-99J Where D o I Find E verything I Need for Process M easurement and C ontrol? O ME GA… O f C ourse! Shop on line at omega.com T EM PE RATUR E R The rmocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies R Wire: Thermocouple, RTD & Thermistor R Calibrators & Ice Point References R Recorders, Control ...

Fabricante Omega Categoría Crib Toy

Los documentos del dispositivo Omega DP3001 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega
- manuales de instrucciones DP3001
- hojas de producto Omega
- folletos informativos
- o etiquetas energéticas Omega DP3001
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega DP3001.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega DP3001, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega DP3001. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega DP3001.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega DP3001, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega DP3001. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega DP3001.

El manual de instrucciones completo de Omega debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega DP3001 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega DP3001, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega DP3001 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega DP3001 - que deben facilitarnos los primeros pasos durante el uso de Omega DP3001
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega DP3001
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega DP3001 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega DP3001?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega DP3001, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega DP3001 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)