Omega DP3001の取扱説明書

24ページ 1.26 mb
ダウンロード

ページに移動 of 24

Summary
  • Omega DP3001 - page 1

    http://www.omega.com e-mail: info@omega.com ™ ® U ser’s Guide DP3001 DIGITAL PANEL VOLTMETER ...

  • Omega DP3001 - page 2

    ...

  • Omega DP3001 - page 3

    i TABLE OF CONTENTS SAFETY CONSIDERATIONS ......................................................................................... iii 1.0 GENERAL INFORMATION ........................................................................................ 1 2.0 SPECIFICATIONS ................................................................................ ...

  • Omega DP3001 - page 4

    ii LIST OF FIGURES: Figure 3.1 DIN Case Dimensions .................................................................................. 4 Figure 3.2 Exploded View .............................................................................................. 5 Figure 4.1 Side View of Transformer ........................................................ ...

  • Omega DP3001 - page 5

    iii SAFETY CONSIDERATIONS This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility). Unpacking & Inspection Unpack the instrument and inspect for obvious shipping d ...

  • Omega DP3001 - page 6

    ...

  • Omega DP3001 - page 7

    1 1.0 GENERAL INFORM AT I ON This voltmeter is a 4 1/2 digit panel meter f or applications which require a compact, quality DC v oltmeter . This model uses dual-slope conversion. Additionally , it provides automatic z eroing before each reading and does so with a minimum of par ts f or increased reliability . The voltmeter has a resolution of 1 par ...

  • Omega DP3001 - page 8

    2 2.4 A CCURA CY A T 25°C Maximum error ±0.01% of reading ±2 counts Span tempco ±0.01% of reading/°C Step response 1 second W ar m-up to rated accuracy 10 minutes 2.5 DIGIT AL INPUTS P ositive true referenced to DIG GND 2.6 ANALOG-T O-DIGIT AL CONVERSION T echnique Dual-slope, av erage-v alue Input integration period 100 milliseconds Read rate ...

  • Omega DP3001 - page 9

    3 2.10 MECHANICAL Bezel 96 x 48 x 5.1 mm (3.78 x 1.89 x 0.20 in) Depth behind bezel 104 mm (4.09 in) (with connector) P anel cutout 92 x 45 mm (3.62 x 1.77 in) W eight 400 g (14 oz) Case material 94V -0 UL-rated polycarbonate D1 connector option PCB edge connector with a double ro w of (non-CE) 18-pins, 3.96 mm (0.156 in) spacing between pin s D4 c ...

  • Omega DP3001 - page 10

    4 Figure 3.2 Exploded View 3.2 P ANEL MOUNTING 1. Remo ve main board connector J1, if installed. Loosen the two clamp screws (with a #8 Phillips screwdriv er) on the rear of case and rotate the slide clamps. Push the two slide retainers to ward the rear of the unit and remov e them. 2. W orking from the front of the panel, inser t the meter into th ...

  • Omega DP3001 - page 11

    5 4.0 POWER AND SIGNAL A C versions of the v oltmeter are factory-set for 115 V ac in the USA and 230 V ac in Europe (using C1 option) ±15% operation. DC versions are preset f or 9-32 Vdc or 26-56 Vdc operation. It is not possible to change the meter from 9-32 Vdc to 26-56 Vdc or vice versa. Different static in verters are installed by the f actor ...

  • Omega DP3001 - page 12

    6 Figure 4.2 Rear T erminal Hookups Wire Color for A C P ower USA Other (High) Black Brown (Low) White Blue (Ground) Green Green Model P ower Signal AC D1 Connector A High 17 High 2 Low 16 L ow C Ear th Ground T Analog Ground D4 Connector 1 High 6 High 2 Low 5 L ow 3 Ear th Ground 4 Analog Ground DC D1 Connector 2 + DC 17 High C - DC (return) 16 L ...

  • Omega DP3001 - page 13

    7 4.3 MAIN BO ARD PIN ASSIGNMENTS (J1 Card Edge) Left to right, looking at rear of case P1 Connection Standard A Spare (E16) 1 No connection B No connection 2 Spare (E18) C Spare (E19) 3 No connection D No connection 4 No connection E Spare (E43) 5 No connection F 1999.9 (DP4) 6 Spare (E24) H 199.99 (DP3) 7 Spare (E23) J 19.999 (DP2) 8 Spare (E22) ...

  • Omega DP3001 - page 14

    8 4.4 SIGNAL INPUTS RA TIO : The reference input allo ws an external voltage to be used as the ref erence source for con version. In this mode, the meter reads the r atio of the signal voltage to the ref erence voltage rather than the true v alue of the input. Signal V oltage Reading in Counts = Ref erence V oltage x 10000 On the 20 V and 200 V ran ...

  • Omega DP3001 - page 15

    9 5.0 CO NFIGURA TION Select the desired configurations from the f ollowing char ts. Install jumpers and open/close solder s witches as indicated. Remov e all push-on jumpers not used. 5.1 DECIMAL POINT SELECTION Figure 5.1 Display Boar d Jumper Locations Decimal P oint S1 Alternate decimal point configuration using main board connector J1. 1.999 ...

  • Omega DP3001 - page 16

    10 5.2 V OL T A GE RANGE SELECTION Figure 5.2 Main Board J umper Locations *Ref er to Figure 5.3 . S3-A is used f or signal connections. Refer to Section 4 f or more information. Input Configuration Solder Switches* Push-on Jumpers Wire Jumper Open Close S2 S4 W10 2 Vdc J, L H, I, K - - Install 20 Vdc J, L H, I, K A B Remove 200 Vdc J, L H, I, K A ...

  • Omega DP3001 - page 17

    11 Figure 5.3 Solder Switch Locations Solder s witch F is used for ref erence input impedance ratio . Ref er to Section 4 for more inf or mation. 6.0 C ALIBRA TION This unit was f actor y-calibrated with a precision v oltage source. F requent calibration is not necessary due to the stability and inter nal accuracy . If calibration is needed, use th ...

  • Omega DP3001 - page 18

    12 7.0 DRA WINGS Figure 7.1 Assembly Dia gram, Main and Display Board ...

  • Omega DP3001 - page 19

    13 8.0 D UAL-SLOPE CONVERSION At the beginning of a conv ersion, the voltage across C int is z ero . The signal is then applied to the integrator and the v oltage across C int rises by the f or mula: T1 E Cint = Esig R int C int At the end of a fix ed per iod of 10000 counts, T1, the counters are reset to 00000. The signal input is turned off and ...

  • Omega DP3001 - page 20

    NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ____________________________ ...

  • Omega DP3001 - page 21

    15 NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________ ...

  • Omega DP3001 - page 22

    16 NOTES ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________ ...

  • Omega DP3001 - page 23

    WARRANTY / DISCLAIMER OMEGA EN GINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineer ing will extend the warranty period for one (1) additional year if the warranty card enclosed with each instru ...

  • Omega DP3001 - page 24

    M5280/1112 11119ML-99J Where D o I Find E verything I Need for Process M easurement and C ontrol? O ME GA… O f C ourse! Shop on line at omega.com T EM PE RATUR E R The rmocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies R Wire: Thermocouple, RTD & Thermistor R Calibrators & Ice Point References R Recorders, Control ...

メーカー Omega カテゴリー Crib Toy

Omega DP3001のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DP3001の取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega DP3001の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega DP3001の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega DP3001の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega DP3001のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega DP3001の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega DP3001デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega DP3001を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega DP3001ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega DP3001の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega DP3001の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega DP3001に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega DP3001デバイスの基本機能を使うにあたってのヒント。 Omega DP3001のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega DP3001に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega DP3001のメーカー/サービスへの連絡先に関する情報。

Omega DP3001についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega DP3001の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega DP3001で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)