    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at DRF-POT FOR POTENTIOMETER INPUT , DRF-RES FOR RESIST ANCE INPUT DRF Series Signal Conditioners U ser ’ s Guide ...

  • Omega Engineering DRF-POT - page 2

    OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi ...

  • Omega Engineering DRF-POT - page 3

    Page 3 User’s Manual DRF Series INDEX GENERAL INFORMATION .................................................. 4 QUICK GUIDE .................................................................... 5 POWER SUPPLY CONNECTIONS ................ 5 SIGNAL ADJUSTMENT .................................. 6 and 7 DIMENSIONS AND CONNECTIONS .............. 8 TECHN ...

  • Omega Engineering DRF-POT - page 4

    Page 4 User’s Manual DRF Series GENERAL INFORMATION The DRF series of Isolated Signal Converters, allow to convert process signals, temperatures, electrical signals, etc, to current loops or voltage signals for further retransmision, while introducing into the system galvanic isolation barriers between the input, the output and the power supply c ...

  • Omega Engineering DRF-POT - page 5

    Page 5 User’s Manual DRF Series QUICK GUIDE The DRF units have a front cover which can be opened down. This cover gives access to the Span and Offset potentiometers, and to the selection jumpers for input and output signal ranges. To open the front cover, press slightly the sides of the cover at the upper side, close to the OUTPUT terminals, as i ...

  • Omega Engineering DRF-POT - page 6

    Page 6 User’s Manual DRF Series SIGNAL ADJUSTMENT To proceed to adjust a range of input and output signals, first select with the appropriate jumpers, the signal ranges Adjustment Example for model DRF-POT 1.- Connect potentiometer to input terminals (8 «term+», 9 «term-» and 7 «signal») 2.- Connect a multimeter to the output signal termina ...

  • Omega Engineering DRF-POT - page 7

    Page 7 User’s Manual DRF Series S ELECTION J UMPERS : I NPUT S IGNAL R ANGE Range : 100% FS Range : 25% FS Range : 50% FS Range : 3 KOhms Range Min : 1.5 KOhms Range : 1.5 KOhms Range Min : 750 Ohms Range : 5 KOhms Range Min : 3 KOhms Range : 10 KOhms Range Min : 5 KOhms DRF-POT for POTENTIOMETER SIGNALS Range : 12.5% FS DRF-RES for RESISTANCE SI ...

  • Omega Engineering DRF-POT - page 8

    Page 8 User’s Manual DRF Series Input Connections POTENTIOMETER RESIST ANCE 9mm (0.35’’) 93mm (3.66’’) 24 Vdc ~ 0 Vdc ~ 110 mm (4.33’’) DIMENSIONS AND CONNECTIONS S pecial W idth for AC Power models AC Powered DC Powered Output Connections 37mm (1.46’’) 22,5mm (0.89’’) ...

  • Omega Engineering DRF-POT - page 9

    Page 9 User’s Manual DRF Series INPUT SIGNAL for POTENTIOMETER RANGES 0/100 % 0/50 % 0/25 % 0/12.5% (minimum 8%) Potentiometer value min 100Ohms max 1MOhm 3 Wire System, 1 Vdc Excitation INPUT SIGNAL in RESISTANCE RANGES 0/10 KOhms 0/5 KOhms 0/3 KOhms 0/1.5 KOhms (minimum 750 Ohms) 2 Wire System, 0.2 mA Excitation OUTPUT SIGNAL in VDC RANGES 0/10 ...

  • Omega Engineering DRF-POT - page 10

    Page 10 User’s Manual DRF Series INSTALATION PRECAUTIONS.- The installation and the future use of this unit must be done by qualified personnel. The unit has not AC (mains) switch, neither internal protection fuse. It will be in operation as soon as power is connected. The installation must incorporate an external mains switch with a protection f ...

  • Omega Engineering DRF-POT - page 11

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega Engineering DRF-POT - page 12

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com M4138/0305 TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Control ...

Fabricante Omega Engineering Categoría Electric Heater

Los documentos del dispositivo Omega Engineering DRF-POT que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omega Engineering
- manuales de instrucciones DRF-POT
- hojas de producto Omega Engineering
- folletos informativos
- o etiquetas energéticas Omega Engineering DRF-POT
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omega Engineering DRF-POT.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omega Engineering DRF-POT, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omega Engineering DRF-POT. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omega Engineering DRF-POT.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Omega Engineering DRF-POT, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omega Engineering DRF-POT. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omega Engineering DRF-POT.

El manual de instrucciones completo de Omega Engineering debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omega Engineering DRF-POT - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omega Engineering DRF-POT, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omega Engineering DRF-POT que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omega Engineering DRF-POT - que deben facilitarnos los primeros pasos durante el uso de Omega Engineering DRF-POT
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omega Engineering DRF-POT
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omega Engineering DRF-POT en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omega Engineering DRF-POT?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omega Engineering DRF-POT, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omega Engineering DRF-POT probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)