Omega Engineering DRF-POTの取扱説明書

12ページ 0.38 mb
ダウンロード

ページに移動 of 12

Summary
  • Omega Engineering DRF-POT - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at DRF-POT FOR POTENTIOMETER INPUT , DRF-RES FOR RESIST ANCE INPUT DRF Series Signal Conditioners U ser ’ s Guide ...

  • Omega Engineering DRF-POT - page 2

    OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi ...

  • Omega Engineering DRF-POT - page 3

    Page 3 User’s Manual DRF Series INDEX GENERAL INFORMATION .................................................. 4 QUICK GUIDE .................................................................... 5 POWER SUPPLY CONNECTIONS ................ 5 SIGNAL ADJUSTMENT .................................. 6 and 7 DIMENSIONS AND CONNECTIONS .............. 8 TECHN ...

  • Omega Engineering DRF-POT - page 4

    Page 4 User’s Manual DRF Series GENERAL INFORMATION The DRF series of Isolated Signal Converters, allow to convert process signals, temperatures, electrical signals, etc, to current loops or voltage signals for further retransmision, while introducing into the system galvanic isolation barriers between the input, the output and the power supply c ...

  • Omega Engineering DRF-POT - page 5

    Page 5 User’s Manual DRF Series QUICK GUIDE The DRF units have a front cover which can be opened down. This cover gives access to the Span and Offset potentiometers, and to the selection jumpers for input and output signal ranges. To open the front cover, press slightly the sides of the cover at the upper side, close to the OUTPUT terminals, as i ...

  • Omega Engineering DRF-POT - page 6

    Page 6 User’s Manual DRF Series SIGNAL ADJUSTMENT To proceed to adjust a range of input and output signals, first select with the appropriate jumpers, the signal ranges Adjustment Example for model DRF-POT 1.- Connect potentiometer to input terminals (8 «term+», 9 «term-» and 7 «signal») 2.- Connect a multimeter to the output signal termina ...

  • Omega Engineering DRF-POT - page 7

    Page 7 User’s Manual DRF Series S ELECTION J UMPERS : I NPUT S IGNAL R ANGE Range : 100% FS Range : 25% FS Range : 50% FS Range : 3 KOhms Range Min : 1.5 KOhms Range : 1.5 KOhms Range Min : 750 Ohms Range : 5 KOhms Range Min : 3 KOhms Range : 10 KOhms Range Min : 5 KOhms DRF-POT for POTENTIOMETER SIGNALS Range : 12.5% FS DRF-RES for RESISTANCE SI ...

  • Omega Engineering DRF-POT - page 8

    Page 8 User’s Manual DRF Series Input Connections POTENTIOMETER RESIST ANCE 9mm (0.35’’) 93mm (3.66’’) 24 Vdc ~ 0 Vdc ~ 110 mm (4.33’’) DIMENSIONS AND CONNECTIONS S pecial W idth for AC Power models AC Powered DC Powered Output Connections 37mm (1.46’’) 22,5mm (0.89’’) ...

  • Omega Engineering DRF-POT - page 9

    Page 9 User’s Manual DRF Series INPUT SIGNAL for POTENTIOMETER RANGES 0/100 % 0/50 % 0/25 % 0/12.5% (minimum 8%) Potentiometer value min 100Ohms max 1MOhm 3 Wire System, 1 Vdc Excitation INPUT SIGNAL in RESISTANCE RANGES 0/10 KOhms 0/5 KOhms 0/3 KOhms 0/1.5 KOhms (minimum 750 Ohms) 2 Wire System, 0.2 mA Excitation OUTPUT SIGNAL in VDC RANGES 0/10 ...

  • Omega Engineering DRF-POT - page 10

    Page 10 User’s Manual DRF Series INSTALATION PRECAUTIONS.- The installation and the future use of this unit must be done by qualified personnel. The unit has not AC (mains) switch, neither internal protection fuse. It will be in operation as soon as power is connected. The installation must incorporate an external mains switch with a protection f ...

  • Omega Engineering DRF-POT - page 11

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega Engineering DRF-POT - page 12

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com M4138/0305 TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Control ...

メーカー Omega Engineering カテゴリー Electric Heater

Omega Engineering DRF-POTのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DRF-POTの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering DRF-POTの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering DRF-POTの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering DRF-POTの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering DRF-POTのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering DRF-POTの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering DRF-POTデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering DRF-POTを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering DRF-POTユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering DRF-POTの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering DRF-POTの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering DRF-POTに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering DRF-POTデバイスの基本機能を使うにあたってのヒント。 Omega Engineering DRF-POTのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering DRF-POTに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering DRF-POTのメーカー/サービスへの連絡先に関する情報。

Omega Engineering DRF-POTについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering DRF-POTの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering DRF-POTで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)