ADC SignalOn Series - page 1
www .adc.com • +1-952-938-8080 • 1-800-366-3891 Spec Sheet SignalOn ® Series RF Signal Management Advanced br oadband services are being developed and launched at an ever -accelerating pace. While these services vary , they have one thing in common. Whether it be high-speed data, video-on-demand, or IP telephony , broadband subscribers expect ...
-
ADC SignalOn Series - page 2
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 2 www .adc.com • +1-952-938-8080 • 1-800-366-3891 fr eq dB Broadband CATV RF Spectrum VOD servers Network diagnostics/test gear QPSK set-top control network CMTS for HSD, Vo IP Fiber plant from subscribers S C A C = Co mbiner S = Splitter A = Amplifier S S S A A A Fibe ...
-
ADC SignalOn Series - page 3
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 3 www .adc.com • +1-952-938-8080 • 1-800-366-3891 T ype 32D 32-position, Drawer 20V 20-position, Vertical 08H 8-position, Horizontal 04H 4-position, Horizontal 02H 2-position, Horizontal Catalog Number N - C __ __ __ __ B Power Kit N No Y Y es* Chassis Description Cata ...
-
ADC SignalOn Series - page 4
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 4 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Plain Splitter/Combiner Module Pad and Monitor Module with Make-Before-Br eak Attenuation Passives: RF Splitter/Combiner Modules 5 MHz to 1 GHz Features Industry's highest density with standard F • and BNC connec ...
-
ADC SignalOn Series - page 5
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 5 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Ordering Information Description Catalog Number Plain Splitter/Combiner Modules BNC connector 2:1 plain N-MPB12 4:1 plain N-MPB14 8:1 plain N-MPB18 3 x 2:1 plain N-MPB32 2 x 4:1 plain N-MPB24 F connector 2:1 plain N-MPF ...
-
ADC SignalOn Series - page 6
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 6 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Description Catalog Number Splitter/Combiner with Pad and Monitor Modules F connector 0 dB default 2:1 combiner with monitor N-MCF12M0 2:1 splitter with monitor N-MSF12M0 2x4:1 combiner with monitor N-MCF24M0 2x4:1 spli ...
-
ADC SignalOn Series - page 7
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 7 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Connector T ype F F B BNC Catalog Number N - MD __ __ __ __ __ Application T ype R Rear narrowcast signal port DC Value 09 9 dB 12 12 dB 20 20 dB V12 12 dB variable Circuit Quantity 1 Single circuit 3 T riple cir cuit O ...
-
ADC SignalOn Series - page 8
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 8 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Features T ypic ally pla ced at the in put to the for war d • path optical transmitter , this module allows for conditioning and grooming of the RF sig nal gain an d slope. I t is desig ned as 1:1 input to output with ...
-
ADC SignalOn Series - page 9
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 9 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Passives: L-Band Satellite Splitter Modules 950 MHz to 2.15 GHz ADC’ s new L-Band series satellite splitter modules ar e engineer ed for the highest performance in the 950 MHz to 2.15 GHz frequency range. These plain ...
-
ADC SignalOn Series - page 10
5/08 • 102721AE SignalOn ® Series 10 www .adc.com • +1-952-938-8080 • 1-800-366-3891 SignalOn ® Series RF Signal Management T oday’ s br oadband services requir e high-quality headend infrastructur e that offers excellent performance, r eliability and design flexibility . Fur therm ore , your inf rast ructu re sol utio n s houl d max imiz ...
-
ADC SignalOn Series - page 11
5/08 • 102721AE SignalOn ® Series 11 www .adc.com • +1-952-938-8080 • 1-800-366-3891 SignalOn ® Series Actives: Forwar d Path Amplifier Actives: Amplifier Modules Amplifier (front view) PERFORMANCE A TTRIBUTE 20 dB Forward Amplifier 30 dB Forward Amplifier Bandwidth 50-1000 MHz 50-1000 MHz Optimum RF input +20 dBmV per channel +10 dBmV p ...
-
ADC SignalOn Series - page 12
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 12 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Actives: Power Supply Modules Specifications PERFORMANCE A TTRIBUTE AC-DC DC-DC Input voltage 90-264 Vac, 50/60 Hz 36-72 Vdc nominal Efficiency 75% nominal 80% nominal Output voltage 24 Vdc ± 5% 24 Vdc ± 5% Output p ...
-
ADC SignalOn Series - page 13
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 13 www .adc.com • +1-952-938-8080 • 1-800-366-3891 The ADC SignalOn ® RF Switch Module (RFSM) is designed for use with the SignalOn 8-position, or 20-position powered chassis. All RF connections to the switch ar e made through standard 75 W BNC, or F connectors on the ...
-
ADC SignalOn Series - page 14
5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 14 www .adc.com • +1-952-938-8080 • 1-800-366-3891 ADC’ s Return Path Amplifie r was des igned specifically to solve pr oblems particular to your envir onment . Pr oviding gr eater densit y , unp ar al lel ed ca bl e ma na ge men t, gr ea ter fu nct io na lit y and r ...
-
ADC SignalOn Series - page 15
5/08 • 102721AE SignalOn ® Series 15 www .adc.com • +1-952-938-8080 • 1-800-366-3891 SignalOn ® Series RF Signal Management * Kit intended for 0 db default MBB modules (-M0 modules) ** Kit intended for 6 db default MBB modules (-M6 modules) Accessories Ordering Information Description Catalog Number Cable Management Kits; (includes rack mou ...
-
ADC SignalOn Series - page 16
Spec Sheet Website: www.adc.com From N orth Ame rica, Ca ll Toll Fre e: 1-800- 366-3 891 • Outsi de of North Am erica : +1-952 -938-8 080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications pu ...
¿Tienes una pregunta acerca de ADC SignalOn Series?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ADC SignalOn Series, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ADC SignalOn Series probablemente compartirá una forma de solucionarlo.