    www .adc.com • +1-952-938-8080 • 1-800-366-3891 Spec Sheet SignalOn ® Series RF Signal Management Advanced br oadband services are being developed and launched at an ever -accelerating pace. While these services vary , they have one thing in common. Whether it be high-speed data, video-on-demand, or IP telephony , broadband subscribers expect ...

  • ADC SignalOn Series - page 2

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 2 www .adc.com • +1-952-938-8080 • 1-800-366-3891 fr eq dB Broadband CATV RF Spectrum VOD servers Network diagnostics/test gear QPSK set-top control network CMTS for HSD, Vo IP Fiber plant from subscribers S C A C = Co mbiner S = Splitter A = Amplifier S S S A A A Fibe ...

  • ADC SignalOn Series - page 3

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 3 www .adc.com • +1-952-938-8080 • 1-800-366-3891 T ype 32D 32-position, Drawer 20V 20-position, Vertical 08H 8-position, Horizontal 04H 4-position, Horizontal 02H 2-position, Horizontal Catalog Number N - C __ __ __ __ B Power Kit N No Y Y es* Chassis Description Cata ...

  • ADC SignalOn Series - page 4

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 4 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Plain Splitter/Combiner Module Pad and Monitor Module with Make-Before-Br eak Attenuation Passives: RF Splitter/Combiner Modules 5 MHz to 1 GHz Features Industry's highest density with standard F • and BNC connec ...

  • ADC SignalOn Series - page 5

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 5 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Ordering Information Description Catalog Number Plain Splitter/Combiner Modules BNC connector 2:1 plain N-MPB12 4:1 plain N-MPB14 8:1 plain N-MPB18 3 x 2:1 plain N-MPB32 2 x 4:1 plain N-MPB24 F connector 2:1 plain N-MPF ...

  • ADC SignalOn Series - page 6

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 6 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Description Catalog Number Splitter/Combiner with Pad and Monitor Modules F connector 0 dB default 2:1 combiner with monitor N-MCF12M0 2:1 splitter with monitor N-MSF12M0 2x4:1 combiner with monitor N-MCF24M0 2x4:1 spli ...

  • ADC SignalOn Series - page 7

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 7 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Connector T ype F F B BNC Catalog Number N - MD __ __ __ __ __ Application T ype R Rear narrowcast signal port DC Value 09 9 dB 12 12 dB 20 20 dB V12 12 dB variable Circuit Quantity 1 Single circuit 3 T riple cir cuit O ...

  • ADC SignalOn Series - page 8

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 8 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Features T ypic ally pla ced at the in put to the for war d • path optical transmitter , this module allows for conditioning and grooming of the RF sig nal gain an d slope. I t is desig ned as 1:1 input to output with ...

  • ADC SignalOn Series - page 9

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 9 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Passives: L-Band Satellite Splitter Modules 950 MHz to 2.15 GHz ADC’ s new L-Band series satellite splitter modules ar e engineer ed for the highest performance in the 950 MHz to 2.15 GHz frequency range. These plain ...

  • ADC SignalOn Series - page 10

    5/08 • 102721AE SignalOn ® Series 10 www .adc.com • +1-952-938-8080 • 1-800-366-3891 SignalOn ® Series RF Signal Management T oday’ s br oadband services requir e high-quality headend infrastructur e that offers excellent performance, r eliability and design flexibility . Fur therm ore , your inf rast ructu re sol utio n s houl d max imiz ...

  • ADC SignalOn Series - page 11

    5/08 • 102721AE SignalOn ® Series 11 www .adc.com • +1-952-938-8080 • 1-800-366-3891 SignalOn ® Series Actives: Forwar d Path Amplifier Actives: Amplifier Modules Amplifier (front view) PERFORMANCE A TTRIBUTE 20 dB Forward Amplifier 30 dB Forward Amplifier Bandwidth 50-1000 MHz 50-1000 MHz Optimum RF input +20 dBmV per channel +10 dBmV p ...

  • ADC SignalOn Series - page 12

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 12 www .adc.com • +1-952-938-8080 • 1-800-366-3891 Actives: Power Supply Modules Specifications PERFORMANCE A TTRIBUTE AC-DC DC-DC Input voltage 90-264 Vac, 50/60 Hz 36-72 Vdc nominal Efficiency 75% nominal 80% nominal Output voltage 24 Vdc ± 5% 24 Vdc ± 5% Output p ...

  • ADC SignalOn Series - page 13

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 13 www .adc.com • +1-952-938-8080 • 1-800-366-3891 The ADC SignalOn ® RF Switch Module (RFSM) is designed for use with the SignalOn 8-position, or 20-position powered chassis. All RF connections to the switch ar e made through standard 75 W BNC, or F connectors on the ...

  • ADC SignalOn Series - page 14

    5/08 • 102721AE SignalOn ® Series SignalOn ® Series RF Signal Management 14 www .adc.com • +1-952-938-8080 • 1-800-366-3891 ADC’ s Return Path Amplifie r was des igned specifically to solve pr oblems particular to your envir onment . Pr oviding gr eater densit y , unp ar al lel ed ca bl e ma na ge men t, gr ea ter fu nct io na lit y and r ...

  • ADC SignalOn Series - page 15

    5/08 • 102721AE SignalOn ® Series 15 www .adc.com • +1-952-938-8080 • 1-800-366-3891 SignalOn ® Series RF Signal Management * Kit intended for 0 db default MBB modules (-M0 modules) ** Kit intended for 6 db default MBB modules (-M6 modules) Accessories Ordering Information Description Catalog Number Cable Management Kits; (includes rack mou ...

  • ADC SignalOn Series - page 16

    Spec Sheet Website: www.adc.com From N orth Ame rica, Ca ll Toll Fre e: 1-800- 366-3 891 • Outsi de of North Am erica : +1-952 -938-8 080 Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications pu ...

Manufacturer ADC Category Network Card

Documents that we receive from a manufacturer of a ADC SignalOn Series can be divided into several groups. They are, among others:
- ADC technical drawings
- SignalOn Series manuals
- ADC product data sheets
- information booklets
- or energy labels ADC SignalOn Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual ADC SignalOn Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ADC SignalOn Series, service manual, brief instructions and user manuals ADC SignalOn Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ADC SignalOn Series.

A complete manual for the device ADC SignalOn Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ADC SignalOn Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ADC SignalOn Series.

A complete ADC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ADC SignalOn Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ADC SignalOn Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ADC SignalOn Series, that we can find in the current document
3. Tips how to use the basic functions of the device ADC SignalOn Series - which should help us in our first steps of using ADC SignalOn Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ADC SignalOn Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ADC SignalOn Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ADC SignalOn Series?

Use the form below

If you did not solve your problem by using a manual ADC SignalOn Series, ask a question using the form below. If a user had a similar problem with ADC SignalOn Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)