Manual de instrucciones A.O. Smith COBT

16 de páginas 0.25 mb
Descargar

Pasar a la página of 16

Summary
  • A.O. Smith COBT - page 1

    1 W ARNING – PROP ANE MODEL W ater heaters for propane gas are different from natural gas models. A natural gas heater will not function safely on propane gas and no attempt should be made to convert a heater from natural gas to propane gas. Propane gas must be used with great caution. It is highly explosive and heavier than air . It collects fir ...

  • A.O. Smith COBT - page 2

    2 FOREWORD This manual is intended to be used in conjunction with other literature provided with the heater . This includes power burner and related gas control information. It is important that this manual and the additional publications be reviewed in their entirety before beginning any work. The installation should be made in accordance with the ...

  • A.O. Smith COBT - page 3

    3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDERW A TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water . IF THE UNIT IS EXPOSED TO THE FOLLOWING , DO NOT OPERA TE HEA TER UNTIL ALL CO ...

  • A.O. Smith COBT - page 4

    4 The water temperature is controlled by two thermostats. One thermostat is located near the top of the tank and the other is in the lower part of the tank. The upper thermostat must be set at least 5°F higher than the lower thermostat. In the case where the water heater has electronic thermosta t s, this differential has been factory set and cann ...

  • A.O. Smith COBT - page 5

    5 The latest version of the National Electrical Code, NFP A No. 70. In Canada refer to Canadian Electrical Code C 22.1, from National Fire Protection Association, 1 Batterymarch Park, Quicy , MA 02269-9101. LOCA TING THE HEA TER When inst alling the heater, consideration must be given to proper location. Location selected should be as close to the ...

  • A.O. Smith COBT - page 6

    6 UNDESIRABLE OPENINGS, CAUSING POOR COMBUSTION. SOOTING MA Y RESUL T WITH AN INCREASED RISK OF ASPHYXIA TION. THERMAL EXP ANSION (CLOSED SYSTEM) Thermal expansion occurs in any hot water system when system water is heated or “recovered” during periods of non-use. If the system is operated in an “open” condition such as being connected dire ...

  • A.O. Smith COBT - page 7

    7 Where an existing chimney or vent is to be used, be sure that the chimney or vent has adequate capacity for the number and sizes of gas appliances being vented through it. Inspect the chimney or vent and remove all soot or other obstructions, which will retard free draft. V ent piping making horizontal runs must have a minimum upward slope toward ...

  • A.O. Smith COBT - page 8

    8 T ABLE 3 EQUIV ALENT LENGTH OF FITTINGS IN FEET Pipe Size (IPS) 1 1.25 1.5 2 2. 5 3 4 S td. T ee through side 5.5 7.5 9 .0 12.0 14.0 17.0 22.0 S td. E1 1 2.7 3 .7 4.3 5.5 6.5 8.0 12.0 45°F E1 1 1.2 1.6 2.0 2.5 3.0 3.7 5.0 Plug Cock 3.0 4.0 5.5 7.5 9.0 12.0 16.0 W ARNING THE HEA TER IS NOT INTENDED FOR OPERA TION A T HIGHER THAN 13.8” W A TER C ...

  • A.O. Smith COBT - page 9

    9 TYPICAL WIRE DIAGRAM BTP , 270 - 2,500 KBTUH COF , 800 - 2,500 KBTUH COBT , 400 - 2,500 KBTUH TYPICAL WIRE DIAGRAM BTP , 140 - 255 KBTUH ...

  • A.O. Smith COBT - page 10

    10 TYPICAL WIRE DIAGRAM COF , 140 - 720 KBTUH TYPICAL WIRE DIAGRAM COBT , 140 - 300 KBTUH ...

  • A.O. Smith COBT - page 11

    11 OF ELECTRICAL SHOCK. DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE HEA TER T ANK IS FILLED WITH W A TER. TWO UNIT MANIFOLD INST ALLA TION Assure water flow balance of all units. Without this balance, the full water heating and storage potential of the system cannot be achieved. Otherwise, the units with the higher water flow may have a shortened ...

  • A.O. Smith COBT - page 12

    12 3. The correct test instruments are: •C O 2 indicator or 0 2 analyzer • CO indicator • Stack thermometer • Draft gauge or inclined manometer • U-tube manometer or calibrated 0-10” and 0-35” w . c. pressure gauge • Combination volt/ammeter . Suggested safety device test procedures are: A. While heater is operating, turn valve, mai ...

  • A.O. Smith COBT - page 13

    13 Lime accumulation not only reduces the life of the equipment but also reduces efficiency of the heater and increases fuel consumption. The usage of water softening equipment greatly reduces the hardness of the water . However , this equipment does not always remove all of the hardness (lime). For this reason it is recommended that a regular sche ...

  • A.O. Smith COBT - page 14

    14 BURNER AIR OPENINGS OR VENTILA TION GRILLES FOR COMBUSTION AIR. REMOVE LINT ACCUMULA TION FROM AIR INT AKE GRILL. At least annually , contact a qualified service agency for burner cleaning and other routine maintenance. CLEANING FLUES-COF & COBT ONL Y The following describes how to gain access to the tank flues for cleaning if necessary . 1. ...

  • A.O. Smith COBT - page 15

    15 W A TER HEA TER MAKES NOISE 1. Sediment or lime scale accumulations cause noises when the heater is operating. • The sounds are normal, however , the tank bottom should be cleaned. Refer to MAINTENANCE for details. 2. Some of the electrical components of the water heater make sounds, which are normal. • Contacts click or snap as the heater s ...

  • A.O. Smith COBT - page 16

    16 CERTIFIED F ACTOR Y ST ART - UP REQUIRED T o activate your warranty , contact your local sales represent ative or Authorized S tart-up Agent to arrange for a FREE Certified S tart-up. A.O. Smith Corporation, the warrantor, extends the following LIMITED W ARRANTY to the owner of this water heater. 1. THE T ANK If the glass lined tank in this wate ...

Fabricante A.O. Smith Categoría Water Heater

Los documentos del dispositivo A.O. Smith COBT que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos A.O. Smith
- manuales de instrucciones COBT
- hojas de producto A.O. Smith
- folletos informativos
- o etiquetas energéticas A.O. Smith COBT
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones A.O. Smith COBT.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje A.O. Smith COBT, instrucciones de servicio, instrucciones cortas o instrucciones de usuario A.O. Smith COBT. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto A.O. Smith COBT.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo A.O. Smith COBT, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar A.O. Smith COBT. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de A.O. Smith COBT.

El manual de instrucciones completo de A.O. Smith debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual A.O. Smith COBT - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice A.O. Smith COBT, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de A.O. Smith COBT que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo A.O. Smith COBT - que deben facilitarnos los primeros pasos durante el uso de A.O. Smith COBT
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con A.O. Smith COBT
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de A.O. Smith COBT en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de A.O. Smith COBT?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con A.O. Smith COBT, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con A.O. Smith COBT probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)