Manuale per l’uso A.O. Smith COBT

16 pagine 0.25 mb
Scarica

Vai alla pagina of 16

Summary
  • A.O. Smith COBT - page 1

    1 W ARNING – PROP ANE MODEL W ater heaters for propane gas are different from natural gas models. A natural gas heater will not function safely on propane gas and no attempt should be made to convert a heater from natural gas to propane gas. Propane gas must be used with great caution. It is highly explosive and heavier than air . It collects fir ...

  • A.O. Smith COBT - page 2

    2 FOREWORD This manual is intended to be used in conjunction with other literature provided with the heater . This includes power burner and related gas control information. It is important that this manual and the additional publications be reviewed in their entirety before beginning any work. The installation should be made in accordance with the ...

  • A.O. Smith COBT - page 3

    3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDERW A TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water . IF THE UNIT IS EXPOSED TO THE FOLLOWING , DO NOT OPERA TE HEA TER UNTIL ALL CO ...

  • A.O. Smith COBT - page 4

    4 The water temperature is controlled by two thermostats. One thermostat is located near the top of the tank and the other is in the lower part of the tank. The upper thermostat must be set at least 5°F higher than the lower thermostat. In the case where the water heater has electronic thermosta t s, this differential has been factory set and cann ...

  • A.O. Smith COBT - page 5

    5 The latest version of the National Electrical Code, NFP A No. 70. In Canada refer to Canadian Electrical Code C 22.1, from National Fire Protection Association, 1 Batterymarch Park, Quicy , MA 02269-9101. LOCA TING THE HEA TER When inst alling the heater, consideration must be given to proper location. Location selected should be as close to the ...

  • A.O. Smith COBT - page 6

    6 UNDESIRABLE OPENINGS, CAUSING POOR COMBUSTION. SOOTING MA Y RESUL T WITH AN INCREASED RISK OF ASPHYXIA TION. THERMAL EXP ANSION (CLOSED SYSTEM) Thermal expansion occurs in any hot water system when system water is heated or “recovered” during periods of non-use. If the system is operated in an “open” condition such as being connected dire ...

  • A.O. Smith COBT - page 7

    7 Where an existing chimney or vent is to be used, be sure that the chimney or vent has adequate capacity for the number and sizes of gas appliances being vented through it. Inspect the chimney or vent and remove all soot or other obstructions, which will retard free draft. V ent piping making horizontal runs must have a minimum upward slope toward ...

  • A.O. Smith COBT - page 8

    8 T ABLE 3 EQUIV ALENT LENGTH OF FITTINGS IN FEET Pipe Size (IPS) 1 1.25 1.5 2 2. 5 3 4 S td. T ee through side 5.5 7.5 9 .0 12.0 14.0 17.0 22.0 S td. E1 1 2.7 3 .7 4.3 5.5 6.5 8.0 12.0 45°F E1 1 1.2 1.6 2.0 2.5 3.0 3.7 5.0 Plug Cock 3.0 4.0 5.5 7.5 9.0 12.0 16.0 W ARNING THE HEA TER IS NOT INTENDED FOR OPERA TION A T HIGHER THAN 13.8” W A TER C ...

  • A.O. Smith COBT - page 9

    9 TYPICAL WIRE DIAGRAM BTP , 270 - 2,500 KBTUH COF , 800 - 2,500 KBTUH COBT , 400 - 2,500 KBTUH TYPICAL WIRE DIAGRAM BTP , 140 - 255 KBTUH ...

  • A.O. Smith COBT - page 10

    10 TYPICAL WIRE DIAGRAM COF , 140 - 720 KBTUH TYPICAL WIRE DIAGRAM COBT , 140 - 300 KBTUH ...

  • A.O. Smith COBT - page 11

    11 OF ELECTRICAL SHOCK. DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE HEA TER T ANK IS FILLED WITH W A TER. TWO UNIT MANIFOLD INST ALLA TION Assure water flow balance of all units. Without this balance, the full water heating and storage potential of the system cannot be achieved. Otherwise, the units with the higher water flow may have a shortened ...

  • A.O. Smith COBT - page 12

    12 3. The correct test instruments are: •C O 2 indicator or 0 2 analyzer • CO indicator • Stack thermometer • Draft gauge or inclined manometer • U-tube manometer or calibrated 0-10” and 0-35” w . c. pressure gauge • Combination volt/ammeter . Suggested safety device test procedures are: A. While heater is operating, turn valve, mai ...

  • A.O. Smith COBT - page 13

    13 Lime accumulation not only reduces the life of the equipment but also reduces efficiency of the heater and increases fuel consumption. The usage of water softening equipment greatly reduces the hardness of the water . However , this equipment does not always remove all of the hardness (lime). For this reason it is recommended that a regular sche ...

  • A.O. Smith COBT - page 14

    14 BURNER AIR OPENINGS OR VENTILA TION GRILLES FOR COMBUSTION AIR. REMOVE LINT ACCUMULA TION FROM AIR INT AKE GRILL. At least annually , contact a qualified service agency for burner cleaning and other routine maintenance. CLEANING FLUES-COF & COBT ONL Y The following describes how to gain access to the tank flues for cleaning if necessary . 1. ...

  • A.O. Smith COBT - page 15

    15 W A TER HEA TER MAKES NOISE 1. Sediment or lime scale accumulations cause noises when the heater is operating. • The sounds are normal, however , the tank bottom should be cleaned. Refer to MAINTENANCE for details. 2. Some of the electrical components of the water heater make sounds, which are normal. • Contacts click or snap as the heater s ...

  • A.O. Smith COBT - page 16

    16 CERTIFIED F ACTOR Y ST ART - UP REQUIRED T o activate your warranty , contact your local sales represent ative or Authorized S tart-up Agent to arrange for a FREE Certified S tart-up. A.O. Smith Corporation, the warrantor, extends the following LIMITED W ARRANTY to the owner of this water heater. 1. THE T ANK If the glass lined tank in this wate ...

Fabbricante A.O. Smith Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoA.O. Smith COBT possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici A.O. Smith
- manuali per l’uso COBT
- schede prodotto A.O. Smith
- opuscoli
- o etichette energetiche A.O. Smith COBT
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso A.O. Smith COBT.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione A.O. Smith COBT, manuali di manutenzione, brevi manuali o manuali utente A.O. Smith COBT. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto A.O. Smith COBT.

Manuali per l’uso simili

Manuale completo del dispositivo A.O. Smith COBT, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare A.O. Smith COBT dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti A.O. Smith COBT.

Il manuale per l’uso completo A.O. Smith, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale A.O. Smith COBT - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice A.O. Smith COBT, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per A.O. Smith COBT che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo A.O. Smith COBT - che ci dovrebbe aiutare nei primi passi durante l'uso A.O. Smith COBT
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del A.O. Smith COBT
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio A.O. Smith COBT in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su A.O. Smith COBT?

Utilizza il modulo sottostante

Se non hai risolto il problema con A.O. Smith COBT con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con A.O. Smith COBT è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)