  • Agilent Technologies 16048A - page 1

    Agilent 1604 8A T est Leads Operation and Service Manual Fourth Edition Agilent T echnologi es Japan, Ltd. Agilent PN 160 48-9000 1 March 2 000 Print ed in: Japan ...

  • Agilent Technologies 16048A - page 2

    2 Notices The in format ion con tained in this docume nt is subjec t to ch ange withou t n otice. This docu ment contains p ropri etary infor mation that is p rotec ted by c opyright. All rights are rese rved. No p art of t his doc ument may be pho tocopi ed, rep roduced, or transl ated to a nother language wi thout the prior writ ten consent of t ...

  • Agilent Technologies 16048A - page 3

    3 • Ground The Instr ument T o avoid electri c shock hazard, t he inst rument chassi s and cabi net must be connecte d to a s afety ea rth gr ound by t he suppli ed power cable with ea rth blade. • DO NOT Operate In An E xplosi ve Atmosphere Do not oper ate the i nstr ument in the prese nce of fl ammable ga sses o r fumes. Operati on of any el ...

  • Agilent Technologies 16048A - page 4

    4 Wa r r a n t y This Ag ilent T echn ologie s inst rument product is war rante d against defec ts in materia l and workmans hip fo r a perio d corre sponding t o the indi vidual warranty periods of it s compone nt product s. Inst rument s are warr anted for a p eriod of o ne year . Fixtures and adapte rs ar e warrant ed for a peri od of 90 days . ...

  • Agilent Technologies 16048A - page 5

    5 Assistance Product ma intena nce agree ments an d other cus t omer a ssistan ce agreements are availa ble for Agilent T echnologi es produc ts. For any as sistance, conta ct your nearest Agilen t T echnologi es Sal es and Servi c e Off ice. Addres ses ar e provide d at t he back of t his manual . Safety S ymbol General definiti ons of safety s ym ...

  • Agilent Technologies 16048A - page 6

    6 ...

  • Agilent Technologies 16048A - page 7

    Contents 7 1. Operation Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 T ypical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Agilent Technologies 16048A - page 8

    8 Contents ...

  • Agilent Technologies 16048A - page 9

    9 1 Operation This oper ating no te prov ides co mplete i nformat ion on th e 16048A T est Le ads. The 16048A is s hown pic toriall y in Figur e 1-1, i ts physic al di mensions ar e given in T able 1-1, a nd typi cal char acteristics related to of fset error are give n in T able 1-2. T o order add ition al copies of th is operat ing not e, use the ...

  • Agilent Technologies 16048A - page 10

    10 Chapter 1 Operation Product Des cription Product Description The 16048A co nsists of a dir ect att achment, 4-terminal pair type fixture which is equip ped w ith f our BNC (m) termi nat ed-co axia l tes t lead s. Th ese te st lead s ar e used to a ttach use r -fabri cated test fi xture s. DC bias le vels of up to ±40 V can be applied to the 160 ...

  • Agilent Technologies 16048A - page 11

    Chapter 1 11 Oper ation Specifications Specifications T able 1-1 Specifications of the 16 048A Function: For use with 4 terminal-pair LCR Meters and Impedance Analy zers. Connector T ype: BNC male Cable Length: Approximately 1m Maximum V oltag e: ± 40V peak max. (AC+DC) W eight: 315 g Safety Stand ards: EN610 10-1:199 3 +A2:1995 IEC6 1010-1: 1990 ...

  • Agilent Technologies 16048A - page 12

    12 Chapter 1 Operation T ypica l Character istics T ypical Characteristics T able 1 -2 T ypical Ch aracteristic s NOTE f is the meas urem ent fr eque ncy in meg ahert z. The incr emen tal er rors c alcul ated from the equation i n the t able for measur ements at f requenci es above 1 MHz are additi ve. Figur e 1-2 Incremental erro r at freq. ³ 1 M ...

  • Agilent Technologies 16048A - page 13

    Chapter 1 13 Oper ation Compensation for Fixtur e Residual Impedance Error Compensation for Fixtur e R esidual Impedance Err or The 16048A ha s inherent stray c apacitan ce, residual in ductanc e, and res idual resist ance that af fect the accura cy of mea sured val ues. T o compe nsate for , or negate, t hese res idual s to minimiz e measur ement ...

  • Agilent Technologies 16048A - page 14

    14 Chapter 1 Operation Compensation for Fixture Residual Impedance Er ror ...

  • Agilent Technologies 16048A - page 15

    15 2 Service ...

  • Agilent Technologies 16048A - page 16

    16 Chapter 2 Serv ice Maintena nce Maintenance An explode d view of the 16 048A (for pa rts i dentifi catio n) is shown in Figure 2-1. Do not dis assemble any furt her than s hown. Maintenance consist s prin cipally o f cleani ng conta cts and r eplacing w orn or d amaged par ts. T ake spe cial car e when cleani ng conta cts. T o order parts, us e ...

  • Agilent Technologies 16048A - page 17

    Chapter 2 17 Service Maintenance Figur e 2-1 Parts Iden tificat ion ...

  • Agilent Technologies 16048A - page 18

    18 Chapter 2 Serv ice Maintena nce T able 2-1 Parts Id entification Reference Agilent Part No. Qty . Description Note 1 * 4 SLEEVE 2 * 4 NUT 3 * 4 NUT 4 * 4 W ASHER 5 * 4 W ASHER 6 2360-0 192 2 SCREW 7 * 1 COVER-BOTTOM 8 * 4 INSULA TOR 9 * 2 CONNECTOR-BNC 10 * 2 CONNECTOR-BNC 1 1 2200-0103 1 S CREW 12 219 0-0206 1 W ASHER 13 160 47-400 00 1 STO PPE ...

  • Agilent Technologies 16048A - page 19

    Chapter 2 19 Service Maintenance *: Not se parat ely repla ceable. 31 1250-01 18 4 CONNECTOR-BNC FEMALE 32 236 0-01 15 2 SCREW 1 thru 30 33 160 32-10021 1 P LA TE 34 219 0-0016 4 W ASHER 35 295 0-0001 4 NUT 36 160 32-10022 1 P LA TE 37 160 32-600 01 1 BNC BRA CKET 31thr u36 a. Agilent interna l -only par t number . Reference Agilent Part No. Qty . ...

  • Agilent Technologies 16048A - page 20

    20 Chapter 2 Serv ice Maintena nce ...

  • Agilent Technologies 16048A - page 21

    REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative. 11/29/99 U ...

Fabricante Agilent Technologies Categoría Power Supply

Los documentos del dispositivo Agilent Technologies 16048A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Agilent Technologies
- manuales de instrucciones 16048A
- hojas de producto Agilent Technologies
- folletos informativos
- o etiquetas energéticas Agilent Technologies 16048A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Agilent Technologies 16048A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Agilent Technologies 16048A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Agilent Technologies 16048A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Agilent Technologies 16048A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Agilent Technologies 16048A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Agilent Technologies 16048A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Agilent Technologies 16048A.

El manual de instrucciones completo de Agilent Technologies debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Agilent Technologies 16048A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Agilent Technologies 16048A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Agilent Technologies 16048A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Agilent Technologies 16048A - que deben facilitarnos los primeros pasos durante el uso de Agilent Technologies 16048A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Agilent Technologies 16048A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Agilent Technologies 16048A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Agilent Technologies 16048A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Agilent Technologies 16048A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Agilent Technologies 16048A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)