    SINGLE-PACKAGE ELECTRIC HEATING COOLING UNITS HRVBBLHU HRVBBSVC HRVBBLVU Heat Recovery Ventilators Form No. PDS HRV.71.1 The Heat Recov er y V entilation (HR V) system off ered by Bryant is the finest unit on the market toda y . The HR VB provides efficient and cost-eff ective heat recov er y during the heating season when needed most. As tempera ...

  • Bryant HRVBBLVU - page 2

    —2— Model number nomenc lature HRV BB LHU 1 150 Maximum Capacity (CFM) 150 CFM 200 CFM 250 CFM 330 CFM Electrical Supply: 1 — 115 volts Descriptor: LHU — Large Horizontal Unit SVU — Small Vertical Unit LVU — Large Vertical Unit Brand: Bryant Equipment Type: Heat Recovery Ventilator Climate Map f or Ener gy and Heat Reco ver y V entilato ...

  • Bryant HRVBBLVU - page 3

    —3— Contr ols and accessories par t no. nomenc lature ACCESSORIES K V B CN 01 01 BAU CONTROL DESCRIPTION BAU — Bryant Automatic Control BBS — Bryant Basic Control BST — Bryant Standard Control ACCESSORY DESCRIPTION 6FM — 6 in. Flowmeters (2) 7FM — 7 in. Flowmeters (2) 8FM — 8 in. Flowmeters (2) EXH — Exhaust Hood HOD — Intake Ho ...

  • Bryant HRVBBLVU - page 4

    —4— CONTROL F EATURES Basic Control: Allows the user to man ually set f an speed to low or high as required to maximiz e comf or t. Standard Contr ol: Off ers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the w all control to low will activ ate the continuous mode. A utomatic Control: ...

  • Bryant HRVBBLVU - page 5

    —5— DIMENSIONS MODEL NO . ABCDE FG in. mm in. mm in. mm in. mm in. mm in. mm in. mm HR VBBLHU1150 15-1/8 384.2 4-1/16 104 5/58 143.3 14-1/2 368.9 10-3/8 288.9 4-3/8 111.3 7-3/4 196.9 HR VBBLHU1250 19 483 5-13/16 147.7 5-1/16 128.1 14-1/2 368.9 11-3/16 283.9 4-3/8 111.3 10-1/16 255.6 A98002 ...

  • Bryant HRVBBLVU - page 6

    —6— 5 3 ⁄ 4 ″ [146.0] D 2 27 ″ [685.8] 22 1 / 16 ″ [560.4] 1 ″ [25.4] 2 PLCS 15 11 ⁄ 16 ″ [398.5] E 3 1 4 1 15 ⁄ 16 ″ [23.8] 3 3 ⁄ 16 ″ [81.0] 4 9 ⁄ 16 ″ [115.9)] F DIA 2 PLCS 19 3 ⁄ 4 ″ [501.7] 5 7 ⁄ 8 ″ DIA [149.2] 2 PLCS WALL CONTROL WIRING 3 ⁄ 8 ″ DIA [9.5] A G DRAINS 11 ⁄ 16 ″ DIA. [17.5] 2 PLCS B ...

  • Bryant HRVBBLVU - page 7

    —7— HR VBBL VU1200 or HR VBBL VU1330 A98001 17 9 ⁄ 16 ″ [446.9] 4 3 ⁄ 4 ″ [120.6] 8 1 ⁄ 8 ″ DIA [206.4] 2 PLCS 5 13 ⁄ 16 ″ [147.6] 5 7 ⁄ 8 ″ DIA [148.2] 2 PLCS 6 15 ⁄ 16 ″ [176.2] 7 1 ⁄ 8 ″ [181.0] 18 5 ⁄ 16 ″ [465.1] 2 3 ⁄ 16 ″ [55.6] 2 PLCS 12 3 ⁄ 4 ″ [323.9] 23 15 ⁄ 16 ″ [608.0] 43 ″ (1092.2) 19 ...

  • Bryant HRVBBLVU - page 8

    —8— PHYSICAL DATA P ERFORMANCE DATA ELECTRICAL DATA MODEL DESCRIPTION CONVENTIONAL COMP A CT HIGH EFFICIENCY Model No. HR VBBVHU1150 HR VBBVHU1260 HR VBBSVC1150 HRVBBSVC1200 HR UBBL VU1150 HR UBBL VU1200 HR UBBL VU1330 P ort Locations Sides Sides T op T op T op T op T op Core T ype P olypropylene Cross Flow P olypropylene Cross Flow P olypropyl ...

  • Bryant HRVBBLVU - page 9

    —9— METHODS TO SIZE HR V’ S METHOD 1 1. Calculate cu ft of occupied space. 2. Multiply by recommended air changes per hr (A C/h). 3. Divide by 60 min utes per hr to conv er t to CFM. EXAMPLE: 2000 sq ft with 8 ft ceiling 0.35 air changes per hr (A C/h) (2000 sq ft x 8 ft ceiling x 0.35 A C/h) / 60 min/h = 93.3 CFM METHOD 2 1. Multiply number ...

  • Bryant HRVBBLVU - page 10

    —1 0— COOLING LOAD BTU The cooling load char t shows loads in Btuh as well. T o use the cooling load char t, first find the design enthalp y from a psychrometric char t using the design dr y bulb and wet b ulb temperatures. (See psychrometric char t on p. 11.) The cooling load can then be f ound f or a range of enthalpies f or each ventilator ...

  • Bryant HRVBBLVU - page 11

    —1 1— .025 .024 .023 .022 .021 .020 .019 .018 .017 .016 .015 .014 .013 .012 .95 .90 .85 .80 .75 .70 .65 .60 .55 .50 .45 .40 .35 .011 .010 .009 .008 .007 .006 .005 .004 .003 .002 .001 0 Sensible heat factor P ounds of moisture per pound of dry air 7 8 9 10 11 12 32 33 34 35 36 37 38 39 40 41 42 43 44 45 47 48 49 46 27 28 29 30 31 19 20 21 22 23 ...

  • Bryant HRVBBLVU - page 12

    —1 2— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: New FORM PDS HRV.71.1 © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 12HR-VBO 3-00 HR V INSTALLED WITH FOR CED AIR SYSTEM HR V INSTALLED WITH INDEPE ...

Fabricante Bryant Categoría Heating System

Los documentos del dispositivo Bryant HRVBBLVU que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bryant
- manuales de instrucciones HRVBBLVU
- hojas de producto Bryant
- folletos informativos
- o etiquetas energéticas Bryant HRVBBLVU
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bryant HRVBBLVU.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bryant HRVBBLVU, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bryant HRVBBLVU. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bryant HRVBBLVU.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bryant HRVBBLVU, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bryant HRVBBLVU. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bryant HRVBBLVU.

El manual de instrucciones completo de Bryant debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bryant HRVBBLVU - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bryant HRVBBLVU, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bryant HRVBBLVU que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bryant HRVBBLVU - que deben facilitarnos los primeros pasos durante el uso de Bryant HRVBBLVU
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bryant HRVBBLVU
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bryant HRVBBLVU en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bryant HRVBBLVU?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant HRVBBLVU, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant HRVBBLVU probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)