Manuale per l’uso Bryant HRVBBLVU

12 pagine 0.17 mb
Scarica

Vai alla pagina of 12

Summary
  • Bryant HRVBBLVU - page 1

    SINGLE-PACKAGE ELECTRIC HEATING COOLING UNITS HRVBBLHU HRVBBSVC HRVBBLVU Heat Recovery Ventilators Form No. PDS HRV.71.1 The Heat Recov er y V entilation (HR V) system off ered by Bryant is the finest unit on the market toda y . The HR VB provides efficient and cost-eff ective heat recov er y during the heating season when needed most. As tempera ...

  • Bryant HRVBBLVU - page 2

    —2— Model number nomenc lature HRV BB LHU 1 150 Maximum Capacity (CFM) 150 CFM 200 CFM 250 CFM 330 CFM Electrical Supply: 1 — 115 volts Descriptor: LHU — Large Horizontal Unit SVU — Small Vertical Unit LVU — Large Vertical Unit Brand: Bryant Equipment Type: Heat Recovery Ventilator Climate Map f or Ener gy and Heat Reco ver y V entilato ...

  • Bryant HRVBBLVU - page 3

    —3— Contr ols and accessories par t no. nomenc lature ACCESSORIES K V B CN 01 01 BAU CONTROL DESCRIPTION BAU — Bryant Automatic Control BBS — Bryant Basic Control BST — Bryant Standard Control ACCESSORY DESCRIPTION 6FM — 6 in. Flowmeters (2) 7FM — 7 in. Flowmeters (2) 8FM — 8 in. Flowmeters (2) EXH — Exhaust Hood HOD — Intake Ho ...

  • Bryant HRVBBLVU - page 4

    —4— CONTROL F EATURES Basic Control: Allows the user to man ually set f an speed to low or high as required to maximiz e comf or t. Standard Contr ol: Off ers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the w all control to low will activ ate the continuous mode. A utomatic Control: ...

  • Bryant HRVBBLVU - page 5

    —5— DIMENSIONS MODEL NO . ABCDE FG in. mm in. mm in. mm in. mm in. mm in. mm in. mm HR VBBLHU1150 15-1/8 384.2 4-1/16 104 5/58 143.3 14-1/2 368.9 10-3/8 288.9 4-3/8 111.3 7-3/4 196.9 HR VBBLHU1250 19 483 5-13/16 147.7 5-1/16 128.1 14-1/2 368.9 11-3/16 283.9 4-3/8 111.3 10-1/16 255.6 A98002 ...

  • Bryant HRVBBLVU - page 6

    —6— 5 3 ⁄ 4 ″ [146.0] D 2 27 ″ [685.8] 22 1 / 16 ″ [560.4] 1 ″ [25.4] 2 PLCS 15 11 ⁄ 16 ″ [398.5] E 3 1 4 1 15 ⁄ 16 ″ [23.8] 3 3 ⁄ 16 ″ [81.0] 4 9 ⁄ 16 ″ [115.9)] F DIA 2 PLCS 19 3 ⁄ 4 ″ [501.7] 5 7 ⁄ 8 ″ DIA [149.2] 2 PLCS WALL CONTROL WIRING 3 ⁄ 8 ″ DIA [9.5] A G DRAINS 11 ⁄ 16 ″ DIA. [17.5] 2 PLCS B ...

  • Bryant HRVBBLVU - page 7

    —7— HR VBBL VU1200 or HR VBBL VU1330 A98001 17 9 ⁄ 16 ″ [446.9] 4 3 ⁄ 4 ″ [120.6] 8 1 ⁄ 8 ″ DIA [206.4] 2 PLCS 5 13 ⁄ 16 ″ [147.6] 5 7 ⁄ 8 ″ DIA [148.2] 2 PLCS 6 15 ⁄ 16 ″ [176.2] 7 1 ⁄ 8 ″ [181.0] 18 5 ⁄ 16 ″ [465.1] 2 3 ⁄ 16 ″ [55.6] 2 PLCS 12 3 ⁄ 4 ″ [323.9] 23 15 ⁄ 16 ″ [608.0] 43 ″ (1092.2) 19 ...

  • Bryant HRVBBLVU - page 8

    —8— PHYSICAL DATA P ERFORMANCE DATA ELECTRICAL DATA MODEL DESCRIPTION CONVENTIONAL COMP A CT HIGH EFFICIENCY Model No. HR VBBVHU1150 HR VBBVHU1260 HR VBBSVC1150 HRVBBSVC1200 HR UBBL VU1150 HR UBBL VU1200 HR UBBL VU1330 P ort Locations Sides Sides T op T op T op T op T op Core T ype P olypropylene Cross Flow P olypropylene Cross Flow P olypropyl ...

  • Bryant HRVBBLVU - page 9

    —9— METHODS TO SIZE HR V’ S METHOD 1 1. Calculate cu ft of occupied space. 2. Multiply by recommended air changes per hr (A C/h). 3. Divide by 60 min utes per hr to conv er t to CFM. EXAMPLE: 2000 sq ft with 8 ft ceiling 0.35 air changes per hr (A C/h) (2000 sq ft x 8 ft ceiling x 0.35 A C/h) / 60 min/h = 93.3 CFM METHOD 2 1. Multiply number ...

  • Bryant HRVBBLVU - page 10

    —1 0— COOLING LOAD BTU The cooling load char t shows loads in Btuh as well. T o use the cooling load char t, first find the design enthalp y from a psychrometric char t using the design dr y bulb and wet b ulb temperatures. (See psychrometric char t on p. 11.) The cooling load can then be f ound f or a range of enthalpies f or each ventilator ...

  • Bryant HRVBBLVU - page 11

    —1 1— .025 .024 .023 .022 .021 .020 .019 .018 .017 .016 .015 .014 .013 .012 .95 .90 .85 .80 .75 .70 .65 .60 .55 .50 .45 .40 .35 .011 .010 .009 .008 .007 .006 .005 .004 .003 .002 .001 0 Sensible heat factor P ounds of moisture per pound of dry air 7 8 9 10 11 12 32 33 34 35 36 37 38 39 40 41 42 43 44 45 47 48 49 46 27 28 29 30 31 19 20 21 22 23 ...

  • Bryant HRVBBLVU - page 12

    —1 2— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: New FORM PDS HRV.71.1 © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 12HR-VBO 3-00 HR V INSTALLED WITH FOR CED AIR SYSTEM HR V INSTALLED WITH INDEPE ...

Fabbricante Bryant Categoria Heating System

I documenti che otteniamo dal fabbricante del dispositivoBryant HRVBBLVU possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso HRVBBLVU
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant HRVBBLVU
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant HRVBBLVU.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant HRVBBLVU, manuali di manutenzione, brevi manuali o manuali utente Bryant HRVBBLVU. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant HRVBBLVU.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant HRVBBLVU, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant HRVBBLVU dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant HRVBBLVU.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant HRVBBLVU - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant HRVBBLVU, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant HRVBBLVU che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant HRVBBLVU - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant HRVBBLVU
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant HRVBBLVU
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant HRVBBLVU in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant HRVBBLVU?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant HRVBBLVU con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant HRVBBLVU è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)