Manual de instrucciones ADTRAN 1xN

12 de páginas 0.23 mb
Descargar

Pasar a la página of 12

Summary
  • ADTRAN 1xN - page 1

    1 61190860L1-5B Section 61190860L1-5, Issue 2 CONTENTS 1. GENERAL ................................................................ 1 2. INSTALLATION ....................................................... 3 3. CONFIGURATION ................................................... 4 4. OPERATIONAL DESCRIPTION ............................. 5 5. NORMAL OPE ...

  • ADTRAN 1xN - page 2

    2 61190860L1-5B Section 61190860L1-5, Issue 2 The SCIM can be locally powered by -48 VDC, or span powered from the standby unit in slot 8 if equipped for span power. Slide switch S1 selects between local or span power. CPE receive and transmit connections are either amphenol or RJ-48C jacks. Revision History Issue 2 adds Auto-Protect information wh ...

  • ADTRAN 1xN - page 3

    3 61190860L1-5B Section 61190860L1-5, Issue 2 Documentation associated with the listed cards provides information on implementing the auto-protect function. LED Indication Table 1 describes LED indication. • All LEDs OFF indicates no power to the SCIM. • All LEDs flashing red indicates the protect card is disabled and SCIM power is local -48 VD ...

  • ADTRAN 1xN - page 4

    4 61190860L1-5B Section 61190860L1-5, Issue 2 Wire-Wrap – The to-facility and from-facility wire-wraps are an alternate method in lieu of the amphenol connections. Customer Side Amphenol Connection – The to-CPE and from-CPE amphenols should be left-side oriented to prevent SCIM panel removal interference after amphenol installation. RJ-48C – ...

  • ADTRAN 1xN - page 5

    5 61190860L1-5B Section 61190860L1-5, Issue 2 Span Power Switch S1 This switch selects between span power or local power. SP AN – The SCIM receives power from the protect card in slot 8. LOCAL – The SCIM receives power from local -48 VDC to terminal strip TB1 on the SCIM card. NOTE Local -48 VDC can be jumpered from the shelf TB1 terminals. Pro ...

  • ADTRAN 1xN - page 6

    6 61190860L1-5B Section 61190860L1-5, Issue 2 the controller card. The controller card will continuously monitor the network receive T1 transmission service in slot 8 (i.e. standby line) for commands. Upon the receipt of these commands, the controller card will initiate the T1 service switchover from the requested line (1 through 7) to the standby ...

  • ADTRAN 1xN - page 7

    7 61190860L1-5B Section 61190860L1-5, Issue 2 Table 2. In-Band Commands d n a m m o C x e H n r e t t a P n r e t t a P y r a n i B g n i m r A h c t i w S0 4 4 C0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 1 e l b a n E t o l S0 4 5 C0 0 0 0 0 0 1 0 1 0 1 0 0 0 1 1 e l b a s i D t o l S0 4 6 C0 0 0 0 0 0 1 0 0 1 1 0 0 0 1 1 e s a e l e R h c t i w SF 4 4 C1 1 1 ...

  • ADTRAN 1xN - page 8

    8 61190860L1-5B Section 61190860L1-5, Issue 2 7. PROTECTION SWITCH Remote provisioning for a protection switch can be accomplished by sending a specific sequence of in-band or out-of-band messages. These remote provisioning commands are transmitted to the controller card from a remote test facility or a T1 test set at a DSX panel. Arming Arming the ...

  • ADTRAN 1xN - page 9

    9 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Protection Switch Protocol See T able 5 for in-band protection switch protocol. Out-of-Band Enable/Disable Protocol See Table 6 for out-of-band slot enable/disable protocol. Out-of-Band Protection Switch Protocol See Table 7 for out-of-band protection switch protocol. Table 5. In-Band Protection ...

  • ADTRAN 1xN - page 10

    10 61190860L1-5B Section 61190860L1-5, Issue 2 See Figure 5 and Figure 6 for switchover codes and traffic results. 8. SWITCHBACK Switchback operation is defined as the re-establishment of the T1 transmission path between the network and the customer using the regularly assigned line. Communication between the COE and RE will be based upon in-band o ...

  • ADTRAN 1xN - page 11

    11 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Release Protocol See Table 8 for return to normal operation. Out-of-Band Release Protocol See Table 9 for return to normal operation. Signal Transmit The controller card will transmit a 0 dB signal. Line Build Out (LBO) The controller card will not provide LBO functions. The controller card wil ...

  • ADTRAN 1xN - page 12

    12 61190860L1-5B Section 61190860L1-5, Issue 2 10. SPECIFICATIONS See Table 10 for Specifications. Table 10. Specifications n o i t a c i f i c e p S : e c a f r e t n I l a c i s y h Pe r i W - 4 : l a n g i Sr a l o p i B 1 T : g n i d o Ce l b i t a p m o c S Z 8 B r o I M A : g n i m a r Fd e m a r f n U r o , F S E , F S : e t a R e n i Lm p p ...

Fabricante ADTRAN Categoría Network Card

Los documentos del dispositivo ADTRAN 1xN que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ADTRAN
- manuales de instrucciones 1xN
- hojas de producto ADTRAN
- folletos informativos
- o etiquetas energéticas ADTRAN 1xN
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ADTRAN 1xN.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ADTRAN 1xN, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ADTRAN 1xN. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ADTRAN 1xN.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ADTRAN 1xN, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ADTRAN 1xN. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ADTRAN 1xN.

El manual de instrucciones completo de ADTRAN debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ADTRAN 1xN - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ADTRAN 1xN, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ADTRAN 1xN que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ADTRAN 1xN - que deben facilitarnos los primeros pasos durante el uso de ADTRAN 1xN
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ADTRAN 1xN
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ADTRAN 1xN en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ADTRAN 1xN?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ADTRAN 1xN, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ADTRAN 1xN probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)