  • ADTRAN 1xN - page 1

    1 61190860L1-5B Section 61190860L1-5, Issue 2 CONTENTS 1. GENERAL ................................................................ 1 2. INSTALLATION ....................................................... 3 3. CONFIGURATION ................................................... 4 4. OPERATIONAL DESCRIPTION ............................. 5 5. NORMAL OPE ...

  • ADTRAN 1xN - page 2

    2 61190860L1-5B Section 61190860L1-5, Issue 2 The SCIM can be locally powered by -48 VDC, or span powered from the standby unit in slot 8 if equipped for span power. Slide switch S1 selects between local or span power. CPE receive and transmit connections are either amphenol or RJ-48C jacks. Revision History Issue 2 adds Auto-Protect information wh ...

  • ADTRAN 1xN - page 3

    3 61190860L1-5B Section 61190860L1-5, Issue 2 Documentation associated with the listed cards provides information on implementing the auto-protect function. LED Indication Table 1 describes LED indication. • All LEDs OFF indicates no power to the SCIM. • All LEDs flashing red indicates the protect card is disabled and SCIM power is local -48 VD ...

  • ADTRAN 1xN - page 4

    4 61190860L1-5B Section 61190860L1-5, Issue 2 Wire-Wrap – The to-facility and from-facility wire-wraps are an alternate method in lieu of the amphenol connections. Customer Side Amphenol Connection – The to-CPE and from-CPE amphenols should be left-side oriented to prevent SCIM panel removal interference after amphenol installation. RJ-48C – ...

  • ADTRAN 1xN - page 5

    5 61190860L1-5B Section 61190860L1-5, Issue 2 Span Power Switch S1 This switch selects between span power or local power. SP AN – The SCIM receives power from the protect card in slot 8. LOCAL – The SCIM receives power from local -48 VDC to terminal strip TB1 on the SCIM card. NOTE Local -48 VDC can be jumpered from the shelf TB1 terminals. Pro ...

  • ADTRAN 1xN - page 6

    6 61190860L1-5B Section 61190860L1-5, Issue 2 the controller card. The controller card will continuously monitor the network receive T1 transmission service in slot 8 (i.e. standby line) for commands. Upon the receipt of these commands, the controller card will initiate the T1 service switchover from the requested line (1 through 7) to the standby ...

  • ADTRAN 1xN - page 7

    7 61190860L1-5B Section 61190860L1-5, Issue 2 Table 2. In-Band Commands d n a m m o C x e H n r e t t a P n r e t t a P y r a n i B g n i m r A h c t i w S0 4 4 C0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 1 e l b a n E t o l S0 4 5 C0 0 0 0 0 0 1 0 1 0 1 0 0 0 1 1 e l b a s i D t o l S0 4 6 C0 0 0 0 0 0 1 0 0 1 1 0 0 0 1 1 e s a e l e R h c t i w SF 4 4 C1 1 1 ...

  • ADTRAN 1xN - page 8

    8 61190860L1-5B Section 61190860L1-5, Issue 2 7. PROTECTION SWITCH Remote provisioning for a protection switch can be accomplished by sending a specific sequence of in-band or out-of-band messages. These remote provisioning commands are transmitted to the controller card from a remote test facility or a T1 test set at a DSX panel. Arming Arming the ...

  • ADTRAN 1xN - page 9

    9 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Protection Switch Protocol See T able 5 for in-band protection switch protocol. Out-of-Band Enable/Disable Protocol See Table 6 for out-of-band slot enable/disable protocol. Out-of-Band Protection Switch Protocol See Table 7 for out-of-band protection switch protocol. Table 5. In-Band Protection ...

  • ADTRAN 1xN - page 10

    10 61190860L1-5B Section 61190860L1-5, Issue 2 See Figure 5 and Figure 6 for switchover codes and traffic results. 8. SWITCHBACK Switchback operation is defined as the re-establishment of the T1 transmission path between the network and the customer using the regularly assigned line. Communication between the COE and RE will be based upon in-band o ...

  • ADTRAN 1xN - page 11

    11 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Release Protocol See Table 8 for return to normal operation. Out-of-Band Release Protocol See Table 9 for return to normal operation. Signal Transmit The controller card will transmit a 0 dB signal. Line Build Out (LBO) The controller card will not provide LBO functions. The controller card wil ...

  • ADTRAN 1xN - page 12

    12 61190860L1-5B Section 61190860L1-5, Issue 2 10. SPECIFICATIONS See Table 10 for Specifications. Table 10. Specifications n o i t a c i f i c e p S : e c a f r e t n I l a c i s y h Pe r i W - 4 : l a n g i Sr a l o p i B 1 T : g n i d o Ce l b i t a p m o c S Z 8 B r o I M A : g n i m a r Fd e m a r f n U r o , F S E , F S : e t a R e n i Lm p p ...

Fabricant ADTRAN Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilADTRAN 1xN peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques ADTRAN
- manuels d’utilisations 1xN
- fiches produit ADTRAN
- dépliants
- ou étiquettes-énergie ADTRAN 1xN
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation ADTRAN 1xN.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation ADTRAN 1xN, manuels d’entretien, brefs manuels ou manuels de l’utilisateur ADTRAN 1xN. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit ADTRAN 1xN.

Manuel d’utilisation complet de l’appareil ADTRAN 1xN, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser ADTRAN 1xN par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs ADTRAN 1xN.

Le manuel d’utilisation complet ADTRAN, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel ADTRAN 1xN - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières ADTRAN 1xN, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lADTRAN 1xN qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil ADTRAN 1xN - qui devraient nous aider dans les premières étapes lors de l'utilisation ADTRAN 1xN
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de ADTRAN 1xN
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service ADTRAN 1xN dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de ADTRAN 1xN?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec ADTRAN 1xN, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec ADTRAN 1xN il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)