    MC COMBOMAX Electric boiler with integrated instantaneous water heater Models from 8 kW to 24 kW : 240 Volts ( single phase ) Use and Care Manual With installation instructions for the contractor Your COMBOMAX ® electric boiler has been carefully assembled and factory tested to provide years of trouble-free service. This manual contains instructio ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 2

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 2. Section 1 : Technical specifications Table 1: Boiler specifications 240 Vac (single phase) : Pow er Nominal load in amps Model Kw BTU/h Heating elements Including the circulator Number of elements Stages Thermostats pilots Wire Cu Fuse Amps COMBOMAX XX-8 8 2 ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 3

    13 6 5 10 12 3 16 8 9 F 4 7 1 I G H C B D E A 2 11 14 15 THERMO 2000 inc. DESSI N D'ATELI ER / GENERAL DI MENSI ONS COMBOMAX XX-XX Legeng/Légende: 1) Boiler Wat er Sup ply Co nnectio n / A limen tation du ch auffage (1" n pt F) 2) Boil er Water Return/ Retou r du chauf fage ( 1" np t F) 3) Dome stic W ater inle t / Entrée eau domes ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 4

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 4. General Safety Precautions Be sure to read and understand the entire Us e & Care Manual before attempting to install or operate this water heater. Pay par ticular attention to the following General Safety Precautions. Failure to follow these warnings could c ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 5

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 5. Section 3 : INSTALLATION The manufacturer’s w arranty does not cover any damage or defect caused by installation or attachment or use of any special attachment other than those authorized by the manufacturer into, onto, or in conjunction w ith the water heater ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 6

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 6. Install shutoff (ball) valves for servicing convenience. Install thermometers on the inlet and outlet lines. Never plug the pressure relief valv e to avoid creating a hazardous situation. 3.5.2 Flow-check valve If the heating system uses a single circulator, a f ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 7

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 7. Pump flow rate = Boiler output ÷ BWTD ÷ 500 • Pump flow rate is expressed in U.S. gallons per minute or GPM. • The Boiler output ( in net BTU per hour) is the maximum amount of heat to be transferred through the heating circuit to meet the hot water demand ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 8

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 8. cold water supply line between the COMBOMAX MC unit and flow check valve. Contact your installing contractor, water supplier, local plumbing inspector or plumbing supply house for assistance. 3.6.3 Recirculation line (if applicable) If a recirculation line is in ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 9

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 9. 3.11 BI-ENERGY SETUP To take advantage of a special domestic electric utility rate, your COMBOMAX MC boiler can be combined with an existing oil or gas-fired furnace. Please contact y our utility to make sure your building is eligible and to find out about the n ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 10

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 10. Section 4 : Operation Before operating this w ater heater, be sure to read and follow these instructions, as well as the w arnings printed in this manual. Failure to do so can result in unsafe operation of the w ater heater resulting in property damage, bodily ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 11

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 11. Adjust the boiler aquastats as required. Please note that lowering the setting will not have an immediate effect as the heat stored in the boiler water must first be consumed. Check the boiler water temperature periodically. Further adjustments may be required ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 12

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 12. 4.6 ADJUSTING THE MIXING VALVE A thermostatically controlled mixing valve works automatically thanks to t he thermostatic element controlling the mix of very hot and cold water as required to provide safe domestic hot water under variable conditions. To adjust ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 13

    THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 Section 5 : Maintenance Regular boiler maintenance will ensure trouble- free service for many years. It is recommended that you set up and follow a maintenance program. All components fail eventually. The use of incorrect repl ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 14

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 14. General Safety Precautions Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this COMBOMAX MC unit. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings co u ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 15

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T Therm ostat Valve de sécurité ( T&P)/ Safet y valv e ( T&P ) à ajouter / to ad d P ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 16

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T Therm ostat Plinthes à ailet tes / Fi nnes-Tube baseboard Valve de sécurité ( T&P)/ Sa ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 17

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping E a u f r o i d e d o m e s t i q u e / D o m e s t i c c o l d w a t e r s up p l y Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T P l i n t he s à a i l e t t e s / F i n ne s - T ub e b a s e ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 18

    L1 G C1 TH 1 TH 2 HL C1 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 24 0 V Modèle/Model 6 - 10 K W Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de puissa n ce Power relay Relais Rela y Lampe témo in Pilot lig ht Haute limit e Hi-Li mit N Circulateu r/ Circulator F Fusibl e Fuse C1 L2 Voir/see note ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 19

    L1 G C1 TH 1 TH 2 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 240V : modèle/ model 15 - 24 K W N C1 L2 C1 TH 3 TH 4 C1 Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de puissa n ce Power relay Relais Rela y Lampe témo in Pilot lig ht Haute limit e Hi-Li mit Fusibl e Fuse EL1 EL2 EL3 EL4 Cabla ge en ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 20

    L1 Diagramme électrique/ Wiri n g dia gr am Contrôle Bi-énergy/ Dual control ener g y CB E -E M N 120 Vac 24 Vac H H V3 V2 E1 E2 T1 T2 Bi-energie/ Dual ene r gy Electrique/ Ele ctr ic Mazout/ Oil Relais/ Re la y COMBOMAX E2 V2 T T Relais chaud ièr e mazout/ Oil boiler Re l ay Noir/ Bl ac k V1 Brun/ Br own Bl e u/ B lue B AB A Electrique/ E l ec ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 21

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed L1 L2 N T T Therm ostat Valve de sécurité ( T&P)/ Safet y valv e ( T&P ) à ajoute r/ to add B A AB Installat ion Bi-é ner ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 22

    Diagramme électrique/ Wiri n g dia gr am Raccordement de zone valves/ Wiring for zoned va lve s system Diagramme électrique/ Wiri n g dia gr am Raccordement de multiples circulateurs/ Wiring for m u ltip le cir c ula to rs 1 22 3 4 1 22 3 4 1 22 3 4 TT Block ter min a l th e r most at /Thermostat t er mi n al b l oc k sur panneau él ec tri que C ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 23

    Aquastat Priorité DHW/ DHW pr iori ty ( Sugg: 160F) Aquastat Élémen t no. 4/ Elemen t no. 4 ( Sugg: 165F) Aquastat Élémen t no. 3/ Elemen t no. 3 ( Sugg: 170F) Aquastat Élémen t no. 2/ Elemen t no. 2 ( Sugg: 175F) Aquastat Élémen t no. 1/ Elemen t no. 1 ( Sugg: 180F) Contact eur pri nci pal / Mai n Contact or Bornier de racco rdement/ Main ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 24

    THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 COMBOMAX TM LIMITED WARRANTY Warranty Coverage for Residential Installatio n. Thermo 2000 Inc. hereby warrants to the or iginal resident ial purchaser t hat the COMBOMAX tank and exchanger (coil assemb ly) installed in a resid ...

Fabricante Thermo Products Categoría Water Heater

Los documentos del dispositivo Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Thermo Products
- manuales de instrucciones Models from 8 kW to 24 kW : 240 Volts ( single phase )
- hojas de producto Thermo Products
- folletos informativos
- o etiquetas energéticas Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ).

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), instrucciones de servicio, instrucciones cortas o instrucciones de usuario Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ). Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ).

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ). Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ).

El manual de instrucciones completo de Thermo Products debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - que deben facilitarnos los primeros pasos durante el uso de Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)