    MC COMBOMAX Electric boiler with integrated instantaneous water heater Models from 8 kW to 24 kW : 240 Volts ( single phase ) Use and Care Manual With installation instructions for the contractor Your COMBOMAX ® electric boiler has been carefully assembled and factory tested to provide years of trouble-free service. This manual contains instructio ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 2

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 2. Section 1 : Technical specifications Table 1: Boiler specifications 240 Vac (single phase) : Pow er Nominal load in amps Model Kw BTU/h Heating elements Including the circulator Number of elements Stages Thermostats pilots Wire Cu Fuse Amps COMBOMAX XX-8 8 2 ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 3

    13 6 5 10 12 3 16 8 9 F 4 7 1 I G H C B D E A 2 11 14 15 THERMO 2000 inc. DESSI N D'ATELI ER / GENERAL DI MENSI ONS COMBOMAX XX-XX Legeng/Légende: 1) Boiler Wat er Sup ply Co nnectio n / A limen tation du ch auffage (1" n pt F) 2) Boil er Water Return/ Retou r du chauf fage ( 1" np t F) 3) Dome stic W ater inle t / Entrée eau domes ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 4

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 4. General Safety Precautions Be sure to read and understand the entire Us e & Care Manual before attempting to install or operate this water heater. Pay par ticular attention to the following General Safety Precautions. Failure to follow these warnings could c ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 5

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 5. Section 3 : INSTALLATION The manufacturer’s w arranty does not cover any damage or defect caused by installation or attachment or use of any special attachment other than those authorized by the manufacturer into, onto, or in conjunction w ith the water heater ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 6

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 6. Install shutoff (ball) valves for servicing convenience. Install thermometers on the inlet and outlet lines. Never plug the pressure relief valv e to avoid creating a hazardous situation. 3.5.2 Flow-check valve If the heating system uses a single circulator, a f ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 7

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 7. Pump flow rate = Boiler output ÷ BWTD ÷ 500 • Pump flow rate is expressed in U.S. gallons per minute or GPM. • The Boiler output ( in net BTU per hour) is the maximum amount of heat to be transferred through the heating circuit to meet the hot water demand ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 8

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 8. cold water supply line between the COMBOMAX MC unit and flow check valve. Contact your installing contractor, water supplier, local plumbing inspector or plumbing supply house for assistance. 3.6.3 Recirculation line (if applicable) If a recirculation line is in ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 9

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 9. 3.11 BI-ENERGY SETUP To take advantage of a special domestic electric utility rate, your COMBOMAX MC boiler can be combined with an existing oil or gas-fired furnace. Please contact y our utility to make sure your building is eligible and to find out about the n ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 10

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 10. Section 4 : Operation Before operating this w ater heater, be sure to read and follow these instructions, as well as the w arnings printed in this manual. Failure to do so can result in unsafe operation of the w ater heater resulting in property damage, bodily ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 11

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 11. Adjust the boiler aquastats as required. Please note that lowering the setting will not have an immediate effect as the heat stored in the boiler water must first be consumed. Check the boiler water temperature periodically. Further adjustments may be required ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 12

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 12. 4.6 ADJUSTING THE MIXING VALVE A thermostatically controlled mixing valve works automatically thanks to t he thermostatic element controlling the mix of very hot and cold water as required to provide safe domestic hot water under variable conditions. To adjust ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 13

    THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 Section 5 : Maintenance Regular boiler maintenance will ensure trouble- free service for many years. It is recommended that you set up and follow a maintenance program. All components fail eventually. The use of incorrect repl ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 14

    COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 14. General Safety Precautions Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this COMBOMAX MC unit. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings co u ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 15

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T Therm ostat Valve de sécurité ( T&P)/ Safet y valv e ( T&P ) à ajouter / to ad d P ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 16

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T Therm ostat Plinthes à ailet tes / Fi nnes-Tube baseboard Valve de sécurité ( T&P)/ Sa ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 17

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping E a u f r o i d e d o m e s t i q u e / D o m e s t i c c o l d w a t e r s up p l y Eau chaude domestique/ Dom estic hot w ater mix ed Val ve 3 voies/ 3 way-valve L1 L2 N T T P l i n t he s à a i l e t t e s / F i n ne s - T ub e b a s e ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 18

    L1 G C1 TH 1 TH 2 HL C1 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 24 0 V Modèle/Model 6 - 10 K W Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de puissa n ce Power relay Relais Rela y Lampe témo in Pilot lig ht Haute limit e Hi-Li mit N Circulateu r/ Circulator F Fusibl e Fuse C1 L2 Voir/see note ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 19

    L1 G C1 TH 1 TH 2 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 240V : modèle/ model 15 - 24 K W N C1 L2 C1 TH 3 TH 4 C1 Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de puissa n ce Power relay Relais Rela y Lampe témo in Pilot lig ht Haute limit e Hi-Li mit Fusibl e Fuse EL1 EL2 EL3 EL4 Cabla ge en ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 20

    L1 Diagramme électrique/ Wiri n g dia gr am Contrôle Bi-énergy/ Dual control ener g y CB E -E M N 120 Vac 24 Vac H H V3 V2 E1 E2 T1 T2 Bi-energie/ Dual ene r gy Electrique/ Ele ctr ic Mazout/ Oil Relais/ Re la y COMBOMAX E2 V2 T T Relais chaud ièr e mazout/ Oil boiler Re l ay Noir/ Bl ac k V1 Brun/ Br own Bl e u/ B lue B AB A Electrique/ E l ec ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 21

    B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic hot w ater mix ed L1 L2 N T T Therm ostat Valve de sécurité ( T&P)/ Safet y valv e ( T&P ) à ajoute r/ to add B A AB Installat ion Bi-é ner ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 22

    Diagramme électrique/ Wiri n g dia gr am Raccordement de zone valves/ Wiring for zoned va lve s system Diagramme électrique/ Wiri n g dia gr am Raccordement de multiples circulateurs/ Wiring for m u ltip le cir c ula to rs 1 22 3 4 1 22 3 4 1 22 3 4 TT Block ter min a l th e r most at /Thermostat t er mi n al b l oc k sur panneau él ec tri que C ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 23

    Aquastat Priorité DHW/ DHW pr iori ty ( Sugg: 160F) Aquastat Élémen t no. 4/ Elemen t no. 4 ( Sugg: 165F) Aquastat Élémen t no. 3/ Elemen t no. 3 ( Sugg: 170F) Aquastat Élémen t no. 2/ Elemen t no. 2 ( Sugg: 175F) Aquastat Élémen t no. 1/ Elemen t no. 1 ( Sugg: 180F) Contact eur pri nci pal / Mai n Contact or Bornier de racco rdement/ Main ...

  • Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - page 24

    THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 COMBOMAX TM LIMITED WARRANTY Warranty Coverage for Residential Installatio n. Thermo 2000 Inc. hereby warrants to the or iginal resident ial purchaser t hat the COMBOMAX tank and exchanger (coil assemb ly) installed in a resid ...

メーカー Thermo Products カテゴリー Water Heater

Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Models from 8 kW to 24 kW : 240 Volts ( single phase )の取扱説明書
- Thermo Productsの製品カード
- パンフレット
- またはThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の取り付け説明書、サービスマニュアル、簡易説明書、またはThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )を使用するのを助ける技術的文書のことです。説明書は通常、全てのThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Thermo Productsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )デバイスの基本機能を使うにあたってのヒント。 Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )のメーカー/サービスへの連絡先に関する情報。

Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがThermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase )で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)