Manual de instrucciones AMX 16-Channel Custom Panel Interface AXP-CPI16

16 de páginas 9.46 mb
Descargar

Pasar a la página of 16

Summary
  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 1

    Operation/Reference Guide Custom Panel I nterfaces AXP-CPI16 16-Channel Custom Panel Interface Last Rev ised: 1/13/ 2009 ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 2

    AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with the follo wing ex cepti ons: • Electrol umine scent and LCD Contro l Panels a re wa rranted f or three (3) year s, excep t for the disp lay an d tou ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 3

    Table of Contents i AXP-CPI16 16-Channel Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ............................. .................... .................... .................... ................ 1 Installat ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 4

    ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 5

    Produc t Info rma tion 1 A XP-CPI16 16-Channel Custom Panel Interface Product Information The AMX AXP-CPI16 16 Channel Custom Panel Interface Board (FIG. 1) simplifies the process of creating custom control panels for Axcess systems. Providing contact closure inputs and feedback outpu ts for up to 16 butto ns, the mini atu re PC boa rd co nta ins a ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 6

    2 AXP-CPI16 16-Channel Custom Panel Interfa ce AXP-CPI16 Specificati ons (Cont.) AXlink S tatus LED Indicates AXlink c ommunication status as follows: • One blink per second communication is functioning. • T wo blinks per second devices specified in the master progr am do not mat ch the specified devices found. • Three blinks per sec ond indi ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 7

    3 A XP-CPI16 16-Channel Custom Panel Interface Installation Mounting Dimensions FIG. 1 AXP-CPI16 mounting dimensions Mounting Dimensions Item Inch mm Item Description A 0.10 2.50 K P2 20-Pin Header .025 inch (6 mm) square pins, .1 inch (2.4 mm) typical spacing B 1.75 44.50 L 0.125 Inch (3.2 mm) mounting holes f or #4-40 (3 m m) sc rews C 1.55 39. 4 ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 8

    4 AXP-CPI16 16-Channel Custom Panel Interfa ce Setting the AXlink Device Number The 8-position dev ice DIP switch defines th e AXP-CPI16 as an AXlink de vice. It can be one of 255 de v ices in the Axcess Control System. Set the de vice number with the total value of all O N (down) positions. As an e xample, the dev ice DIP switch sho w n belo w def ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 9

    5 A XP-CPI16 16-Channel Custom Panel Interface Switch Wiring Diagrams FIG. 2 diagram s LED and Switch w iring. Connecting the AXlink Wiring T o install the AXlink data/power b us wiring . 1. Strip 0.25 inch of f the wire insulation for all four wires. If the wire is 20 A WG or less, fold the exposed wire o ver to obtain a positiv e connection. 2. I ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 10

    ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 11

    Progra mming 7 A XP-CPI16 16-Channel Custom Panel Interface Programming Use the same Axcess commands as with other AXlink control panels, such as the AXU-MSP series mini-softwire panels. When using the AXP-CPI16 as a control device, use On, Off, and Pulse co mmands to control sources connected to outputs and Push and Release co m mands to receiv e ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 12

    8 AXP-CPI16 16-Channel Custom Panel Interfa ce Testing the Unit If you hav e p rogrammed the Axcess software, load the program into a PC connected to the control system Ma ster port. See Prog ramming on page 4. 1. Push switches connected to the AXP-CPI16. 2. Look at th e lower left of the Axcess screen to verify that the correct d ev ice and ch ann ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 13

    AXP-CPI16 System Worksheet 9 A XP-CPI16 16-Channel Custom Panel Interface AXP-CPI16 System Worksheet Deale r ID Date Deale r PO Numb er J ob SO Numb er Descript ion Serial N umbe r Re v Number Device Numb er 4 3 2 1 15 16 4 3 14 2 13 1 6 5 18 6 17 5 8 7 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In +12 VDC PWR GND N/C N/C 12 10 ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 14

    10 AXP-CPI16 16-Channel Custom Panel Interfa ce 12 11 10 9 15 16 4 3 14 2 13 1 14 13 18 6 17 5 16 15 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In +12 VDC PWR GND N/C N/C 12 10 11 9 Channel Pin Number 20-PIN HEADER HEAD ER P3 FUNCTION Pin Number Out In Out In Out In Out In Out In Out In Out In Out In N/C N/C +12 VDC PW R GND ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 15

    ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 16

    1/09 © 2 009 AMX. All right s reserved. AMX and the AMX log o are regist ered tradema rks of AMX . AMX reser ves the right t o alter sp ecific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical ...

Fabricante AMX Categoría Network Card

Los documentos del dispositivo AMX 16-Channel Custom Panel Interface AXP-CPI16 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos AMX
- manuales de instrucciones 16-Channel Custom Panel Interface AXP-CPI16
- hojas de producto AMX
- folletos informativos
- o etiquetas energéticas AMX 16-Channel Custom Panel Interface AXP-CPI16
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones AMX 16-Channel Custom Panel Interface AXP-CPI16.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje AMX 16-Channel Custom Panel Interface AXP-CPI16, instrucciones de servicio, instrucciones cortas o instrucciones de usuario AMX 16-Channel Custom Panel Interface AXP-CPI16. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto AMX 16-Channel Custom Panel Interface AXP-CPI16.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo AMX 16-Channel Custom Panel Interface AXP-CPI16, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar AMX 16-Channel Custom Panel Interface AXP-CPI16. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de AMX 16-Channel Custom Panel Interface AXP-CPI16.

El manual de instrucciones completo de AMX debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual AMX 16-Channel Custom Panel Interface AXP-CPI16 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice AMX 16-Channel Custom Panel Interface AXP-CPI16, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de AMX 16-Channel Custom Panel Interface AXP-CPI16 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo AMX 16-Channel Custom Panel Interface AXP-CPI16 - que deben facilitarnos los primeros pasos durante el uso de AMX 16-Channel Custom Panel Interface AXP-CPI16
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con AMX 16-Channel Custom Panel Interface AXP-CPI16
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de AMX 16-Channel Custom Panel Interface AXP-CPI16 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de AMX 16-Channel Custom Panel Interface AXP-CPI16?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con AMX 16-Channel Custom Panel Interface AXP-CPI16, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con AMX 16-Channel Custom Panel Interface AXP-CPI16 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)