AMX 16-Channel Custom Panel Interface AXP-CPI16の取扱説明書

16ページ 9.46 mb
ダウンロード

ページに移動 of 16

Summary
  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 1

    Operation/Reference Guide Custom Panel I nterfaces AXP-CPI16 16-Channel Custom Panel Interface Last Rev ised: 1/13/ 2009 ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 2

    AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with the follo wing ex cepti ons: • Electrol umine scent and LCD Contro l Panels a re wa rranted f or three (3) year s, excep t for the disp lay an d tou ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 3

    Table of Contents i AXP-CPI16 16-Channel Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ............................. .................... .................... .................... ................ 1 Installat ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 4

    ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 5

    Produc t Info rma tion 1 A XP-CPI16 16-Channel Custom Panel Interface Product Information The AMX AXP-CPI16 16 Channel Custom Panel Interface Board (FIG. 1) simplifies the process of creating custom control panels for Axcess systems. Providing contact closure inputs and feedback outpu ts for up to 16 butto ns, the mini atu re PC boa rd co nta ins a ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 6

    2 AXP-CPI16 16-Channel Custom Panel Interfa ce AXP-CPI16 Specificati ons (Cont.) AXlink S tatus LED Indicates AXlink c ommunication status as follows: • One blink per second communication is functioning. • T wo blinks per second devices specified in the master progr am do not mat ch the specified devices found. • Three blinks per sec ond indi ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 7

    3 A XP-CPI16 16-Channel Custom Panel Interface Installation Mounting Dimensions FIG. 1 AXP-CPI16 mounting dimensions Mounting Dimensions Item Inch mm Item Description A 0.10 2.50 K P2 20-Pin Header .025 inch (6 mm) square pins, .1 inch (2.4 mm) typical spacing B 1.75 44.50 L 0.125 Inch (3.2 mm) mounting holes f or #4-40 (3 m m) sc rews C 1.55 39. 4 ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 8

    4 AXP-CPI16 16-Channel Custom Panel Interfa ce Setting the AXlink Device Number The 8-position dev ice DIP switch defines th e AXP-CPI16 as an AXlink de vice. It can be one of 255 de v ices in the Axcess Control System. Set the de vice number with the total value of all O N (down) positions. As an e xample, the dev ice DIP switch sho w n belo w def ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 9

    5 A XP-CPI16 16-Channel Custom Panel Interface Switch Wiring Diagrams FIG. 2 diagram s LED and Switch w iring. Connecting the AXlink Wiring T o install the AXlink data/power b us wiring . 1. Strip 0.25 inch of f the wire insulation for all four wires. If the wire is 20 A WG or less, fold the exposed wire o ver to obtain a positiv e connection. 2. I ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 10

    ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 11

    Progra mming 7 A XP-CPI16 16-Channel Custom Panel Interface Programming Use the same Axcess commands as with other AXlink control panels, such as the AXU-MSP series mini-softwire panels. When using the AXP-CPI16 as a control device, use On, Off, and Pulse co mmands to control sources connected to outputs and Push and Release co m mands to receiv e ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 12

    8 AXP-CPI16 16-Channel Custom Panel Interfa ce Testing the Unit If you hav e p rogrammed the Axcess software, load the program into a PC connected to the control system Ma ster port. See Prog ramming on page 4. 1. Push switches connected to the AXP-CPI16. 2. Look at th e lower left of the Axcess screen to verify that the correct d ev ice and ch ann ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 13

    AXP-CPI16 System Worksheet 9 A XP-CPI16 16-Channel Custom Panel Interface AXP-CPI16 System Worksheet Deale r ID Date Deale r PO Numb er J ob SO Numb er Descript ion Serial N umbe r Re v Number Device Numb er 4 3 2 1 15 16 4 3 14 2 13 1 6 5 18 6 17 5 8 7 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In +12 VDC PWR GND N/C N/C 12 10 ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 14

    10 AXP-CPI16 16-Channel Custom Panel Interfa ce 12 11 10 9 15 16 4 3 14 2 13 1 14 13 18 6 17 5 16 15 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In +12 VDC PWR GND N/C N/C 12 10 11 9 Channel Pin Number 20-PIN HEADER HEAD ER P3 FUNCTION Pin Number Out In Out In Out In Out In Out In Out In Out In Out In N/C N/C +12 VDC PW R GND ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 15

    ...

  • AMX 16-Channel Custom Panel Interface AXP-CPI16 - page 16

    1/09 © 2 009 AMX. All right s reserved. AMX and the AMX log o are regist ered tradema rks of AMX . AMX reser ves the right t o alter sp ecific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical ...

メーカー AMX カテゴリー Network Card

AMX 16-Channel Custom Panel Interface AXP-CPI16のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 16-Channel Custom Panel Interface AXP-CPI16の取扱説明書
- AMXの製品カード
- パンフレット
- またはAMX 16-Channel Custom Panel Interface AXP-CPI16の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、AMX 16-Channel Custom Panel Interface AXP-CPI16の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、AMX 16-Channel Custom Panel Interface AXP-CPI16の取り付け説明書、サービスマニュアル、簡易説明書、またはAMX 16-Channel Custom Panel Interface AXP-CPI16のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、AMX 16-Channel Custom Panel Interface AXP-CPI16の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

AMX 16-Channel Custom Panel Interface AXP-CPI16デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAMX 16-Channel Custom Panel Interface AXP-CPI16を使用するのを助ける技術的文書のことです。説明書は通常、全てのAMX 16-Channel Custom Panel Interface AXP-CPI16ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

AMXの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. AMX 16-Channel Custom Panel Interface AXP-CPI16の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAMX 16-Channel Custom Panel Interface AXP-CPI16の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。AMX 16-Channel Custom Panel Interface AXP-CPI16に関してこのドキュメントで見つけることができる全てのヒントの目次
3. AMX 16-Channel Custom Panel Interface AXP-CPI16デバイスの基本機能を使うにあたってのヒント。 AMX 16-Channel Custom Panel Interface AXP-CPI16のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。AMX 16-Channel Custom Panel Interface AXP-CPI16に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAMX 16-Channel Custom Panel Interface AXP-CPI16のメーカー/サービスへの連絡先に関する情報。

AMX 16-Channel Custom Panel Interface AXP-CPI16についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAMX 16-Channel Custom Panel Interface AXP-CPI16の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAMX 16-Channel Custom Panel Interface AXP-CPI16で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)