  • Raritan Engineering PST*02 - page 1

    1 1-800-352-5630 www .raritaneng. com IMPOR T ANT SAFETY I NSTRUCTIONS FOR HANDLING PURASAN ® T ABLETS AND SOLUTION W ARNING: HAZARD OF DANGEROUS CHEMICAL REACTION 1. Use ONL Y Purasan T ablets. 2. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P . - Cleans Potties and R.C. Raritan Concentrate ...

  • Raritan Engineering PST*02 - page 2

    2 OPERA TION (depends on installation chosen) Single Button operation - Both toilet and Purasan are operated by one of the following options: Option #1: Switch Panel "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will mome ...

  • Raritan Engineering PST*02 - page 3

    3 MAINTENANCE Use ONLY Purasan Tablets. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P. - Cleans Potties and R.C. Raritan Concentrate are the only factory-recognized cleaning products that may be used in the toilet. MAINTENANCE WARNING: Read and understand all safety instructions (including Ma ...

  • Raritan Engineering PST*02 - page 4

    4 WINTERIZING T ablet Dispenser 1. Close flow metering clamp and disconnect power to water solenoid, if used, to prevent intake wa- ter from entering tablet dispenser . 2. Flush toilet and activate treatment cycle several times to leave just water in tank. 3. Carefully remove small tube from white “T” fitting or check valve from water solenoid ...

  • Raritan Engineering PST*02 - page 5

    5 RECOMMISSIONINGST ART -UP Recommissioning IMPOR T ANT :  Do not load T ablet Cartridge into Dispenser until system is powered and operational.  Do Not Operate Purasan until T reatment Unit is filled with water . T reatment T ank 1. Reconnect hoses and open seacocks. 2. Reconnect wires and turn power on. NOTE: Purasan treatment tank must be ...

  • Raritan Engineering PST*02 - page 6

    6 SPECIFICA TIONS U.S.C.G. Type I MSD Certification #159.015/106/0 Maximum Roll/Pitch Angle: 30° Maximum Temperature Exposure: 120° F (49° C) Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush) Water - fresh, salt or brackish CONVERSIONS Wire - A WG to mm 2 Feet to Meters t e e F 0 15 10 25 20 30 40 5 r e t e M 1 . 36 . 41 . 66 . 72 ...

  • Raritan Engineering PST*02 - page 7

    7 INST ALLA TION MOUNTING T reatment T ank W ARNING: DO NOT locate in an ar ea where ambient temperature exceeds 120 o F (49 o C). 1 . Locate top of treatment tank at or below discharge of toilet and within six feet (1.5 m). Note: If mounting treatment tank higher than discharge. Contact Raritan 2 . Make and secure mounting frame to flat surface. 3 ...

  • Raritan Engineering PST*02 - page 8

    8 INST ALLA TION Raw Water Toilets - 1. T urn off power to toilet. 2. Close intake and discharge seacocks and drain water from toilet system. 3. Disconnect intake hose from bowl elbow . 4. Remove existing bowl elbow and install new bowl elbow supplied with Purasan. 5. Insert the “T” fitting in the hose between the output of the pump and the new ...

  • Raritan Engineering PST*02 - page 9

    9 WIRING WIRING W ARNING: Hazard of Shock and Fire • Always use proper wire, wir e connectors and fuse/circuit br eaker . See Specification Chart. • Secure wir e properly . • Do not connect other appliances to Purasan circuit. • Make sure power is off before proceeding. • Improper wiring can damage the Circuit Board and void warranty . NO ...

  • Raritan Engineering PST*02 - page 10

    10 WIRING Flushing Option #1: "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will momentarily flush the toilet. 1. Mount Switch Panel near toilet. CAUTION: Use only the Raritan #CDS (fail- ure to do so will damage to the C ...

  • Raritan Engineering PST*02 - page 11

    11 TROUBLESHOOTING TROUBLESHOOTING W ARNING: After the tablet dispenser has had water added, it contains a very strong halogen solution. Always wear protective gloves and ventilate well to work on tablet dispenser . Before doing any maintenance or repairs, follow WINTERIZING/STORAGE pr ocedures No Water to tablet dispenser • Clogged check valve ( ...

  • Raritan Engineering PST*02 - page 12

    12 EXPLODED P ARTS 10 17 18 8 7 21 63 64 56 43 45 6 42 43 47 49 32 31 29 28 53 23 55 50 23 23 24 22 41-100 ...

  • Raritan Engineering PST*02 - page 13

    13 EXPLODED P ARTS PURASAN PARTS LIST Item Part # Description 50 41-110 Vent Kit for Tablet Dispenser (Incl. #53, 54, & 55) 51 M3 1 #14 Brass Flat Washer (4) 52 M3 0 1/4"-20 Brass Nut (4) 41-100 Tablet Dispenser Complete (less cartridge) 41-200 T-Fitting (Incl. #33, 34, 37 &38) 42-1000 Treatment Unit Complete 12 V DC 43-1000 Treatment ...

  • Raritan Engineering PST*02 - page 14

    14 DUAL INSTALLATION - “Push Button” also activates Purasan - PBS Battery 3 amp Fuse Small post on CDS to S2 and PBS CDS T o toilet positive (+) Purasan Circuit Board on T reatment tank Freshwater Solenoid valve wiring Battery DUAL INST ALLA TION IMPOR T ANT :  Dual toilet installations requir e either independant operation of toilet and tre ...

  • Raritan Engineering PST*02 - page 15

    15 NOTE: Discharge of raw , untreated sewage is prohibited in all U.S. waters inside the thr ee mile limit except in the Gulf of Mexico where the limit is nine miles. "Y" valves, if installed, must dir ect toilet discharge to a U.S.C.G. approved treatment system or holding tank and must be secur ed in that position while inside the three- ...

  • Raritan Engineering PST*02 - page 16

    16 L405 0911kgs S pecifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 Website: www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 Mark (2) Mounting Holes Level Ac ...

Fabricant Raritan Engineering Catégorie Marine Sanitation System

Les documents que nous recevons du fabricant de l'appareilRaritan Engineering PST*02 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Raritan Engineering
- manuels d’utilisations PST*02
- fiches produit Raritan Engineering
- dépliants
- ou étiquettes-énergie Raritan Engineering PST*02
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Raritan Engineering PST*02.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Raritan Engineering PST*02, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Raritan Engineering PST*02. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Raritan Engineering PST*02.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Raritan Engineering PST*02, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Raritan Engineering PST*02 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Raritan Engineering PST*02.

Le manuel d’utilisation complet Raritan Engineering, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Raritan Engineering PST*02 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Raritan Engineering PST*02, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRaritan Engineering PST*02 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Raritan Engineering PST*02 - qui devraient nous aider dans les premières étapes lors de l'utilisation Raritan Engineering PST*02
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Raritan Engineering PST*02
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Raritan Engineering PST*02 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Raritan Engineering PST*02?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Raritan Engineering PST*02, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Raritan Engineering PST*02 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)