Manuale per l’uso Raritan Engineering PST*02

16 pagine 0.41 mb
Scarica

Vai alla pagina of 16

Summary
  • Raritan Engineering PST*02 - page 1

    1 1-800-352-5630 www .raritaneng. com IMPOR T ANT SAFETY I NSTRUCTIONS FOR HANDLING PURASAN ® T ABLETS AND SOLUTION W ARNING: HAZARD OF DANGEROUS CHEMICAL REACTION 1. Use ONL Y Purasan T ablets. 2. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P . - Cleans Potties and R.C. Raritan Concentrate ...

  • Raritan Engineering PST*02 - page 2

    2 OPERA TION (depends on installation chosen) Single Button operation - Both toilet and Purasan are operated by one of the following options: Option #1: Switch Panel "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will mome ...

  • Raritan Engineering PST*02 - page 3

    3 MAINTENANCE Use ONLY Purasan Tablets. DO NOT add any other chemicals or cleaning products to the toilet or the treatment system. Raritan C.P. - Cleans Potties and R.C. Raritan Concentrate are the only factory-recognized cleaning products that may be used in the toilet. MAINTENANCE WARNING: Read and understand all safety instructions (including Ma ...

  • Raritan Engineering PST*02 - page 4

    4 WINTERIZING T ablet Dispenser 1. Close flow metering clamp and disconnect power to water solenoid, if used, to prevent intake wa- ter from entering tablet dispenser . 2. Flush toilet and activate treatment cycle several times to leave just water in tank. 3. Carefully remove small tube from white “T” fitting or check valve from water solenoid ...

  • Raritan Engineering PST*02 - page 5

    5 RECOMMISSIONINGST ART -UP Recommissioning IMPOR T ANT :  Do not load T ablet Cartridge into Dispenser until system is powered and operational.  Do Not Operate Purasan until T reatment Unit is filled with water . T reatment T ank 1. Reconnect hoses and open seacocks. 2. Reconnect wires and turn power on. NOTE: Purasan treatment tank must be ...

  • Raritan Engineering PST*02 - page 6

    6 SPECIFICA TIONS U.S.C.G. Type I MSD Certification #159.015/106/0 Maximum Roll/Pitch Angle: 30° Maximum Temperature Exposure: 120° F (49° C) Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush) Water - fresh, salt or brackish CONVERSIONS Wire - A WG to mm 2 Feet to Meters t e e F 0 15 10 25 20 30 40 5 r e t e M 1 . 36 . 41 . 66 . 72 ...

  • Raritan Engineering PST*02 - page 7

    7 INST ALLA TION MOUNTING T reatment T ank W ARNING: DO NOT locate in an ar ea where ambient temperature exceeds 120 o F (49 o C). 1 . Locate top of treatment tank at or below discharge of toilet and within six feet (1.5 m). Note: If mounting treatment tank higher than discharge. Contact Raritan 2 . Make and secure mounting frame to flat surface. 3 ...

  • Raritan Engineering PST*02 - page 8

    8 INST ALLA TION Raw Water Toilets - 1. T urn off power to toilet. 2. Close intake and discharge seacocks and drain water from toilet system. 3. Disconnect intake hose from bowl elbow . 4. Remove existing bowl elbow and install new bowl elbow supplied with Purasan. 5. Insert the “T” fitting in the hose between the output of the pump and the new ...

  • Raritan Engineering PST*02 - page 9

    9 WIRING WIRING W ARNING: Hazard of Shock and Fire • Always use proper wire, wir e connectors and fuse/circuit br eaker . See Specification Chart. • Secure wir e properly . • Do not connect other appliances to Purasan circuit. • Make sure power is off before proceeding. • Improper wiring can damage the Circuit Board and void warranty . NO ...

  • Raritan Engineering PST*02 - page 10

    10 WIRING Flushing Option #1: "Push to Cycle" button activates both the toilet and treatment cycle. Note: Toilet flush time is set at 10 seconds, after initial 10 seconds holding the button down will momentarily flush the toilet. 1. Mount Switch Panel near toilet. CAUTION: Use only the Raritan #CDS (fail- ure to do so will damage to the C ...

  • Raritan Engineering PST*02 - page 11

    11 TROUBLESHOOTING TROUBLESHOOTING W ARNING: After the tablet dispenser has had water added, it contains a very strong halogen solution. Always wear protective gloves and ventilate well to work on tablet dispenser . Before doing any maintenance or repairs, follow WINTERIZING/STORAGE pr ocedures No Water to tablet dispenser • Clogged check valve ( ...

  • Raritan Engineering PST*02 - page 12

    12 EXPLODED P ARTS 10 17 18 8 7 21 63 64 56 43 45 6 42 43 47 49 32 31 29 28 53 23 55 50 23 23 24 22 41-100 ...

  • Raritan Engineering PST*02 - page 13

    13 EXPLODED P ARTS PURASAN PARTS LIST Item Part # Description 50 41-110 Vent Kit for Tablet Dispenser (Incl. #53, 54, & 55) 51 M3 1 #14 Brass Flat Washer (4) 52 M3 0 1/4"-20 Brass Nut (4) 41-100 Tablet Dispenser Complete (less cartridge) 41-200 T-Fitting (Incl. #33, 34, 37 &38) 42-1000 Treatment Unit Complete 12 V DC 43-1000 Treatment ...

  • Raritan Engineering PST*02 - page 14

    14 DUAL INSTALLATION - “Push Button” also activates Purasan - PBS Battery 3 amp Fuse Small post on CDS to S2 and PBS CDS T o toilet positive (+) Purasan Circuit Board on T reatment tank Freshwater Solenoid valve wiring Battery DUAL INST ALLA TION IMPOR T ANT :  Dual toilet installations requir e either independant operation of toilet and tre ...

  • Raritan Engineering PST*02 - page 15

    15 NOTE: Discharge of raw , untreated sewage is prohibited in all U.S. waters inside the thr ee mile limit except in the Gulf of Mexico where the limit is nine miles. "Y" valves, if installed, must dir ect toilet discharge to a U.S.C.G. approved treatment system or holding tank and must be secur ed in that position while inside the three- ...

  • Raritan Engineering PST*02 - page 16

    16 L405 0911kgs S pecifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 Website: www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 Mark (2) Mounting Holes Level Ac ...

Fabbricante Raritan Engineering Categoria Marine Sanitation System

I documenti che otteniamo dal fabbricante del dispositivoRaritan Engineering PST*02 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Raritan Engineering
- manuali per l’uso PST*02
- schede prodotto Raritan Engineering
- opuscoli
- o etichette energetiche Raritan Engineering PST*02
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Raritan Engineering PST*02.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Raritan Engineering PST*02, manuali di manutenzione, brevi manuali o manuali utente Raritan Engineering PST*02. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Raritan Engineering PST*02.

Manuale completo del dispositivo Raritan Engineering PST*02, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Raritan Engineering PST*02 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Raritan Engineering PST*02.

Il manuale per l’uso completo Raritan Engineering, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Raritan Engineering PST*02 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Raritan Engineering PST*02, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Raritan Engineering PST*02 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Raritan Engineering PST*02 - che ci dovrebbe aiutare nei primi passi durante l'uso Raritan Engineering PST*02
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Raritan Engineering PST*02
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Raritan Engineering PST*02 in un dato paese, se il problema non può essere risolto da noi stessi.