  • Omega Engineering DP3300 Series - page 1

    Programmable Dual Channel Monitor DP3300 Series User's Manual OMEGA ENGINEERING, INC., ONE OMEGA DRIVE, STAM FORD, CT 06907 ...

  • Omega Engineering DP3300 Series - page 2

    DP3300 Series Us er’s Man ual Page 1 SPECIFICATIONS: ................................................................................................................ ............................................................3 DESCRIPTION:............................................................................................................ ...

  • Omega Engineering DP3300 Series - page 3

    DP3300 Series Us er’s Man ual Page 2 Turning a Ch annel ON or OFF .................................................................................................... .................................................18 MODES OF OPERATION FOR A PULSE INPUT CHANNEL: .................................................................................. ...

  • Omega Engineering DP3300 Series - page 4

    DP3300 Series Us er’s Man ual Page 3 SPECIFICATIONS: (Typical @ 25C and rated supply voltage unless otherwise s pecified) STANDARD INPUTS • * 4- 20m a 10-50m a 0- 5Vdc 0-10Vdc • Thermocouple inputs: J,K,T,E,R,S,B • Cold junction compensation error: +/- 1C (10C to 40C) • Open input indication: HELP display ed • Temperature display able i ...

  • Omega Engineering DP3300 Series - page 5

    DP3300 Series Us er’s Man ual Page 4 DESCRIPTION: A hi ghly vers atile series, DP3300 off ers a uniqu e com bination of tw o an alog chan nels or tw o puls e input ch annels or a combin ation of pu lse (square w av e) on one ch annel and an analog s ignal on the other. This f eature allow s it to be u sed as counter, rat e, RPM or a frequen cy mo ...

  • Omega Engineering DP3300 Series - page 6

    DP3300 Series Us er’s Man ual Page 5 Table 1. How to Display Parameters PEAKS: A very us eful f unction on the sy st em is tracking th e high est (peak) an d the low est (v alley ) poin t attained by each chan nel. Th is is particularly h elpful if an operation is not being constantly w atched or is left unattended e.g. overn ight. DISPLAYING PEA ...

  • Omega Engineering DP3300 Series - page 7

    DP3300 Series Us er’s Man ual Page 6 RESETTING PEAKS Peaks can be reset to cu rrent process v alue e.g. if chann el 1 is reading 200 C , its peaks can be reset to 200. This w ill allow tracking from the current process reading . To reset high peak , first select th e chann el w hose peak is desired to be reset (by pushing the ‘ CH. SEL’ key). ...

  • Omega Engineering DP3300 Series - page 8

    DP3300 Series Us er’s Man ual Page 7 below the lim it (m inus th e relay) deadband. The second mode is man ual reset. Once the lim its are energ ized, they w ill stay energized un til manu ally reset. (NOTE: In the RPM mode, the rate time base m ust be sm aller than the selected filter value. If not, the system will autom atically consider the fi ...

  • Omega Engineering DP3300 Series - page 9

    DP3300 Series Us er’s Man ual Page 8 MODES OF OPERATION FOR COUNTER: COUNT UP CONFIGURATION: MODE 0: (Count up with manual reset to zero) In this m ode the s yst em cou nts up f rom zero. Preset lim its energ ize w hen the cou nt reaches presets lim it values. The un it will con tinue counting up until m anually reset. To reset the count man uall ...

  • Omega Engineering DP3300 Series - page 10

    DP3300 Series Us er’s Man ual Page 9 RESETTING COUNT: The COUNT shown for each ch annel can be reset to zero or preset for a count dow n (depending on coun ter m ode) at any time. To reset the count m anually , first select a chan nel by push ing CH SEL key and ,while ke epi ng t he CH SEL key pushed , push the RESET key sim ultan eously. The dis ...

  • Omega Engineering DP3300 Series - page 11

    DP3300 Series Us er’s Man ual Page10 the in dication of the elaps ed tim e. Maxim u m t im e indicated i s 999.59.59 hours . To reset the timing and start it all over ag ain, first push th e TIME key and w hile keeping it push ed, press the RESET key. T he time w ill res et and start ov er from 000.00.00 hours. SETUP: Setup mode provides a means ...

  • Omega Engineering DP3300 Series - page 12

    DP3300 Series Us er’s Man ual Page11 ‘Channel ON/ OFF’ Setup After display ing inpu t type, the nex t step turns a chan nel ON or OFF. This determines w hether a chan nel is scanned and displayed or not. If for any reason a chann el is not being used, it should be turned OFF. This w ill prevent the u nit from spen ding any time s canning it a ...

  • Omega Engineering DP3300 Series - page 13

    DP3300 Series Us er’s Man ual Page12 suppos e a flow transducer ou tputs a 0.130Vdc to 5.000Vdc sig nal w hich corres ponds to a flow rate of 0 to 40 gal ./min. Then to mak e the 0.130Vdc correspond to a display of 0, set OFFSET =0.130. NOTE: If the input ty p e is CURRENT, the Offset value is en tered in milliam ps. If the input ty pe is VOLTAGE ...

  • Omega Engineering DP3300 Series - page 14

    DP3300 Series Us er’s Man ual Page13 When this parameter is set for "Normally Closed", the relay is closed w hen readings are below LIMIT, and opens w hen the channel readin g exceeds its LIMIT value. The disp lay will show 'LTx N.O .' (where ‘ x’ is the chann el num ber) for a Normally Open settin g or 'LT x N.C.&apo ...

  • Omega Engineering DP3300 Series - page 15

    DP3300 Series Us er’s Man ual Page14 Display Options On pushing SETUP key w hile the display is flashin g SYS , the display briefly show s 'dSP O P t' (for displ ay opt ion) and t hen the current Display Op tio n setting. Follow ing display options are selectable. Use ^v key to step thru these options. Once th e desired Dis play Option ...

  • Omega Engineering DP3300 Series - page 16

    DP3300 Series Us er’s Man ual Page15 1. Connect a th ermocouple calibratio n source to the unit. 2. Dial in 1100 degrees cen tigrade on the calibrator (N ote: un it m ust be program me d for display ing in centig rade). 3. Adjust the gain pot (s ee diagram of rear view of inst rum ent) on the back of th e instrum ent un til the display reads &apo ...

  • Omega Engineering DP3300 Series - page 17

    DP3300 Series Us er’s Man ual Page16 SET UP Voltage or Current Setup Thermocouple / RTD / Thermister Setup Select Channel Turn Ch On/Off Select I nput Ty pe Turn Ch On/Off Select I nput Ty pe Enter Decimal Point Enter Tare Enter Proce ss Limits (1 thru 3) Enter Relay Deadban d Prog. Relay Latching / N on L atching Prog. Engineering Units Select R ...

  • Omega Engineering DP3300 Series - page 18

    DP3300 Series Us er’s Man ual Page17 SET UP Select Sy stem or Channel Progr amming For Sy stem Programing Refer to Flow Chart for Analog I nput SE LEC T INPUT TY PE 1. Voltage 2. Cu rrent 3. J T/C 4. K T/C 5. T T /C 6. E T/C 7. Pulse Turn CH On/Off Low F r e q . High Freq. RPM Counter Rate Enter Rate Time Base Select Filter Value Select Counter M ...

  • Omega Engineering DP3300 Series - page 19

    DP3300 Series Us er’s Man ual Page18 SETUP FOR A PULSE CHANNEL: Turning a Channel ON or OFF The very f irst thing af ter selecting a chan nel is to turn it on or off. A channel should be turned off if it is n o t being used . Use ^v key to select the desired setting. If a channel is OFF, the display w ill show ' CHx OFF' (where ‘x’ ...

  • Omega Engineering DP3300 Series - page 20

    DP3300 Series Us er’s Man ual Page19 FUNCTION DISPLAY SHOWS TO CHANGE active digit flash ing. active digit. Divis ion Factor 'dIV FAC' follow ed by preset Push ^v key to increment or decrem ent divis ion fact or e.g. 12 with active digit. Push <NXT> key to active digit flas hing. change activ e digit. Lim it 1 'CH1 LT1' ...

  • Omega Engineering DP3300 Series - page 21

    DP3300 Series Us er’s Man ual Page20 FUNCTION DISPLAY SHOWS TO CHANGE Latchi ng or no n - 'LATCH' for l atchi ng mode. Push ^v key to obtain alternate mode. latching relay setup. 'NON LCH' for no n latc hing mode . Lim it outpu ts prog- LT1 N.O. or LT1 N.C Use ^V key to obtain ramm ed as normally LT2 N.O. or LT2 N.C alternate ...

  • Omega Engineering DP3300 Series - page 22

    DP3300 Series Us er’s Man ual Page21 If the un it is setup as an RPM monitor then followin g steps are performed for setting u p various parameters: FUNCTION DISPLAY SHOWS TO CHANGE Filter value 1,2,4,6,10,15,20,30,60 Pus h ^v key t o obtain desired valu e Decimal poin t dP 9999 Push ^v key to placemen t dP 999.9 move decim al dP 99.99 point to d ...

  • Omega Engineering DP3300 Series - page 23

    DP3300 Series Us er’s Man ual Page22 NOTE: Pr o cess value for respective relay must be below lim it value for it to reset. Other wise th e key sequen ce will be ignore d. Open Collector (solid state) output Option: DP3300 units can be ordered with either open collector ou tputs or electro-m echanical relay s. (Check m odel num ber printed on the ...

  • Omega Engineering DP3300 Series - page 24

    DP3300 Series Us er’s Man ual Page23 FIG. 3: Power, Input/Output connections & rear view of the instrument. INPUT/OUTPUT CONNECTOR PIN ASSIGNMENTS PIN NO DESCRI PTI ON 1 CHANNEL1, L IMI T 1 NORMALL Y OPEN/OPEN COLL EC TOR NEGATIVE 2 CHANNEL1, LI MIT 1 COMMON/OPEN COL LECTOR POSITI VE 3 CHANNEL1, LI MIT 2 NORMAL LY OPEN/OPEN COLL ECTOR NEGATIV ...

  • Omega Engineering DP3300 Series - page 25

    DP3300 Series Us er’s Man ual Page24 MOUNTING 3.70” (94m m ) 4.05 ” (10 2.87 mm) 1.77” ( 4 5 mm) 0.15 ” dia . (3 . 81m m) Figure 4. Panel Cutout Dimensions 1. Cut out P anel and mount i ng hole d imensions a s shown in figure 8 ab ove . 2. Remove the nut s fr om the mounti ng sc rews on the Pa ne l Met er ( see p ictur e be low). 3. Inser ...

  • Omega Engineering DP3300 Series - page 26

    DP3300 Series Us er’s Man ual Page25 WARRANTY/DISCLAIMER ...

  • Omega Engineering DP3300 Series - page 27

    DP3300 Series Us er’s Man ual Page26 ...

  • Omega Engineering DP3300 Series - page 28

    DP3300 Series Us er’s Man ual Page27 ...

Fabricant Omega Engineering Catégorie Computer Monitor

Les documents que nous recevons du fabricant de l'appareilOmega Engineering DP3300 Series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega Engineering
- manuels d’utilisations DP3300 Series
- fiches produit Omega Engineering
- dépliants
- ou étiquettes-énergie Omega Engineering DP3300 Series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega Engineering DP3300 Series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega Engineering DP3300 Series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega Engineering DP3300 Series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega Engineering DP3300 Series.

Manuel d’utilisation complet de l’appareil Omega Engineering DP3300 Series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega Engineering DP3300 Series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega Engineering DP3300 Series.

Le manuel d’utilisation complet Omega Engineering, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega Engineering DP3300 Series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega Engineering DP3300 Series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega Engineering DP3300 Series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega Engineering DP3300 Series - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega Engineering DP3300 Series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega Engineering DP3300 Series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega Engineering DP3300 Series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega Engineering DP3300 Series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega Engineering DP3300 Series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega Engineering DP3300 Series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)