    Programmable Dual Channel Monitor DP3300 Series User's Manual OMEGA ENGINEERING, INC., ONE OMEGA DRIVE, STAM FORD, CT 06907 ...

  • Omega Engineering DP3300 Series - page 2

    DP3300 Series Us er’s Man ual Page 1 SPECIFICATIONS: ................................................................................................................ ............................................................3 DESCRIPTION:............................................................................................................ ...

  • Omega Engineering DP3300 Series - page 3

    DP3300 Series Us er’s Man ual Page 2 Turning a Ch annel ON or OFF .................................................................................................... .................................................18 MODES OF OPERATION FOR A PULSE INPUT CHANNEL: .................................................................................. ...

  • Omega Engineering DP3300 Series - page 4

    DP3300 Series Us er’s Man ual Page 3 SPECIFICATIONS: (Typical @ 25C and rated supply voltage unless otherwise s pecified) STANDARD INPUTS • * 4- 20m a 10-50m a 0- 5Vdc 0-10Vdc • Thermocouple inputs: J,K,T,E,R,S,B • Cold junction compensation error: +/- 1C (10C to 40C) • Open input indication: HELP display ed • Temperature display able i ...

  • Omega Engineering DP3300 Series - page 5

    DP3300 Series Us er’s Man ual Page 4 DESCRIPTION: A hi ghly vers atile series, DP3300 off ers a uniqu e com bination of tw o an alog chan nels or tw o puls e input ch annels or a combin ation of pu lse (square w av e) on one ch annel and an analog s ignal on the other. This f eature allow s it to be u sed as counter, rat e, RPM or a frequen cy mo ...

  • Omega Engineering DP3300 Series - page 6

    DP3300 Series Us er’s Man ual Page 5 Table 1. How to Display Parameters PEAKS: A very us eful f unction on the sy st em is tracking th e high est (peak) an d the low est (v alley ) poin t attained by each chan nel. Th is is particularly h elpful if an operation is not being constantly w atched or is left unattended e.g. overn ight. DISPLAYING PEA ...

  • Omega Engineering DP3300 Series - page 7

    DP3300 Series Us er’s Man ual Page 6 RESETTING PEAKS Peaks can be reset to cu rrent process v alue e.g. if chann el 1 is reading 200 C , its peaks can be reset to 200. This w ill allow tracking from the current process reading . To reset high peak , first select th e chann el w hose peak is desired to be reset (by pushing the ‘ CH. SEL’ key). ...

  • Omega Engineering DP3300 Series - page 8

    DP3300 Series Us er’s Man ual Page 7 below the lim it (m inus th e relay) deadband. The second mode is man ual reset. Once the lim its are energ ized, they w ill stay energized un til manu ally reset. (NOTE: In the RPM mode, the rate time base m ust be sm aller than the selected filter value. If not, the system will autom atically consider the fi ...

  • Omega Engineering DP3300 Series - page 9

    DP3300 Series Us er’s Man ual Page 8 MODES OF OPERATION FOR COUNTER: COUNT UP CONFIGURATION: MODE 0: (Count up with manual reset to zero) In this m ode the s yst em cou nts up f rom zero. Preset lim its energ ize w hen the cou nt reaches presets lim it values. The un it will con tinue counting up until m anually reset. To reset the count man uall ...

  • Omega Engineering DP3300 Series - page 10

    DP3300 Series Us er’s Man ual Page 9 RESETTING COUNT: The COUNT shown for each ch annel can be reset to zero or preset for a count dow n (depending on coun ter m ode) at any time. To reset the count m anually , first select a chan nel by push ing CH SEL key and ,while ke epi ng t he CH SEL key pushed , push the RESET key sim ultan eously. The dis ...

  • Omega Engineering DP3300 Series - page 11

    DP3300 Series Us er’s Man ual Page10 the in dication of the elaps ed tim e. Maxim u m t im e indicated i s 999.59.59 hours . To reset the timing and start it all over ag ain, first push th e TIME key and w hile keeping it push ed, press the RESET key. T he time w ill res et and start ov er from 000.00.00 hours. SETUP: Setup mode provides a means ...

  • Omega Engineering DP3300 Series - page 12

    DP3300 Series Us er’s Man ual Page11 ‘Channel ON/ OFF’ Setup After display ing inpu t type, the nex t step turns a chan nel ON or OFF. This determines w hether a chan nel is scanned and displayed or not. If for any reason a chann el is not being used, it should be turned OFF. This w ill prevent the u nit from spen ding any time s canning it a ...

  • Omega Engineering DP3300 Series - page 13

    DP3300 Series Us er’s Man ual Page12 suppos e a flow transducer ou tputs a 0.130Vdc to 5.000Vdc sig nal w hich corres ponds to a flow rate of 0 to 40 gal ./min. Then to mak e the 0.130Vdc correspond to a display of 0, set OFFSET =0.130. NOTE: If the input ty p e is CURRENT, the Offset value is en tered in milliam ps. If the input ty pe is VOLTAGE ...

  • Omega Engineering DP3300 Series - page 14

    DP3300 Series Us er’s Man ual Page13 When this parameter is set for "Normally Closed", the relay is closed w hen readings are below LIMIT, and opens w hen the channel readin g exceeds its LIMIT value. The disp lay will show 'LTx N.O .' (where ‘ x’ is the chann el num ber) for a Normally Open settin g or 'LT x N.C.&apo ...

  • Omega Engineering DP3300 Series - page 15

    DP3300 Series Us er’s Man ual Page14 Display Options On pushing SETUP key w hile the display is flashin g SYS , the display briefly show s 'dSP O P t' (for displ ay opt ion) and t hen the current Display Op tio n setting. Follow ing display options are selectable. Use ^v key to step thru these options. Once th e desired Dis play Option ...

  • Omega Engineering DP3300 Series - page 16

    DP3300 Series Us er’s Man ual Page15 1. Connect a th ermocouple calibratio n source to the unit. 2. Dial in 1100 degrees cen tigrade on the calibrator (N ote: un it m ust be program me d for display ing in centig rade). 3. Adjust the gain pot (s ee diagram of rear view of inst rum ent) on the back of th e instrum ent un til the display reads &apo ...

  • Omega Engineering DP3300 Series - page 17

    DP3300 Series Us er’s Man ual Page16 SET UP Voltage or Current Setup Thermocouple / RTD / Thermister Setup Select Channel Turn Ch On/Off Select I nput Ty pe Turn Ch On/Off Select I nput Ty pe Enter Decimal Point Enter Tare Enter Proce ss Limits (1 thru 3) Enter Relay Deadban d Prog. Relay Latching / N on L atching Prog. Engineering Units Select R ...

  • Omega Engineering DP3300 Series - page 18

    DP3300 Series Us er’s Man ual Page17 SET UP Select Sy stem or Channel Progr amming For Sy stem Programing Refer to Flow Chart for Analog I nput SE LEC T INPUT TY PE 1. Voltage 2. Cu rrent 3. J T/C 4. K T/C 5. T T /C 6. E T/C 7. Pulse Turn CH On/Off Low F r e q . High Freq. RPM Counter Rate Enter Rate Time Base Select Filter Value Select Counter M ...

  • Omega Engineering DP3300 Series - page 19

    DP3300 Series Us er’s Man ual Page18 SETUP FOR A PULSE CHANNEL: Turning a Channel ON or OFF The very f irst thing af ter selecting a chan nel is to turn it on or off. A channel should be turned off if it is n o t being used . Use ^v key to select the desired setting. If a channel is OFF, the display w ill show ' CHx OFF' (where ‘x’ ...

  • Omega Engineering DP3300 Series - page 20

    DP3300 Series Us er’s Man ual Page19 FUNCTION DISPLAY SHOWS TO CHANGE active digit flash ing. active digit. Divis ion Factor 'dIV FAC' follow ed by preset Push ^v key to increment or decrem ent divis ion fact or e.g. 12 with active digit. Push <NXT> key to active digit flas hing. change activ e digit. Lim it 1 'CH1 LT1' ...

  • Omega Engineering DP3300 Series - page 21

    DP3300 Series Us er’s Man ual Page20 FUNCTION DISPLAY SHOWS TO CHANGE Latchi ng or no n - 'LATCH' for l atchi ng mode. Push ^v key to obtain alternate mode. latching relay setup. 'NON LCH' for no n latc hing mode . Lim it outpu ts prog- LT1 N.O. or LT1 N.C Use ^V key to obtain ramm ed as normally LT2 N.O. or LT2 N.C alternate ...

  • Omega Engineering DP3300 Series - page 22

    DP3300 Series Us er’s Man ual Page21 If the un it is setup as an RPM monitor then followin g steps are performed for setting u p various parameters: FUNCTION DISPLAY SHOWS TO CHANGE Filter value 1,2,4,6,10,15,20,30,60 Pus h ^v key t o obtain desired valu e Decimal poin t dP 9999 Push ^v key to placemen t dP 999.9 move decim al dP 99.99 point to d ...

  • Omega Engineering DP3300 Series - page 23

    DP3300 Series Us er’s Man ual Page22 NOTE: Pr o cess value for respective relay must be below lim it value for it to reset. Other wise th e key sequen ce will be ignore d. Open Collector (solid state) output Option: DP3300 units can be ordered with either open collector ou tputs or electro-m echanical relay s. (Check m odel num ber printed on the ...

  • Omega Engineering DP3300 Series - page 24

    DP3300 Series Us er’s Man ual Page23 FIG. 3: Power, Input/Output connections & rear view of the instrument. INPUT/OUTPUT CONNECTOR PIN ASSIGNMENTS PIN NO DESCRI PTI ON 1 CHANNEL1, L IMI T 1 NORMALL Y OPEN/OPEN COLL EC TOR NEGATIVE 2 CHANNEL1, LI MIT 1 COMMON/OPEN COL LECTOR POSITI VE 3 CHANNEL1, LI MIT 2 NORMAL LY OPEN/OPEN COLL ECTOR NEGATIV ...

  • Omega Engineering DP3300 Series - page 25

    DP3300 Series Us er’s Man ual Page24 MOUNTING 3.70” (94m m ) 4.05 ” (10 2.87 mm) 1.77” ( 4 5 mm) 0.15 ” dia . (3 . 81m m) Figure 4. Panel Cutout Dimensions 1. Cut out P anel and mount i ng hole d imensions a s shown in figure 8 ab ove . 2. Remove the nut s fr om the mounti ng sc rews on the Pa ne l Met er ( see p ictur e be low). 3. Inser ...

  • Omega Engineering DP3300 Series - page 26

    DP3300 Series Us er’s Man ual Page25 WARRANTY/DISCLAIMER ...

  • Omega Engineering DP3300 Series - page 27

    DP3300 Series Us er’s Man ual Page26 ...

  • Omega Engineering DP3300 Series - page 28

    DP3300 Series Us er’s Man ual Page27 ...

メーカー Omega Engineering カテゴリー Computer Monitor

Omega Engineering DP3300 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DP3300 Seriesの取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering DP3300 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering DP3300 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering DP3300 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering DP3300 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering DP3300 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Omega Engineering DP3300 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering DP3300 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering DP3300 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering DP3300 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering DP3300 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering DP3300 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering DP3300 Seriesデバイスの基本機能を使うにあたってのヒント。 Omega Engineering DP3300 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering DP3300 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering DP3300 Seriesのメーカー/サービスへの連絡先に関する情報。

Omega Engineering DP3300 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering DP3300 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering DP3300 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)