Manuel d’utilisation Goodman Mfg GPG13

40 pages 1.29 mb
Télécharger

Aller à la page of 40

Summary
  • Goodman Mfg GPG13 - page 1

    Affix this manual and Users Information Manual adjacent to the unit. INST ALLA TION & OPERA TING INSTRUCTIONS for GPG13 SINGLE P ACKAGE GAS-ELECTRIC HEA TING & COOLING UNIT C US ® Goodman Manufacturing Company , L.P . IO-288B 5151 San Felipe, Suite 500, Houston, TX 77056 07/08 www .goodmanmfg.com © 2005 - 2008 Goodman Manufacturing Compan ...

  • Goodman Mfg GPG13 - page 2

    2 INDEX Replacement Part s ............................................................................................................................................................. 3 O RDERING P ARTS .............................................................................................................................................. 3 S ...

  • Goodman Mfg GPG13 - page 3

    3 REPLACEMENT PAR TS O RDERING P ARTS When reporting shortages or damages, or ordering repair parts, give the complete unit model and serial numbers as stamped on the unit’s nameplate. Replacement part s for this appliance are available through your contractor or local distributor . For the location of your nearest distributor , consult the white ...

  • Goodman Mfg GPG13 - page 4

    4 CA RBON M ONOXIDE POISON ING HA Z A RD B10259-216 Carbo n mon oxi de pr o duci ng devi ces (s uc h as an a uto mob ile, s pac e heater , gas wat er heat er, etc.) shoul d not be op er ated i n enc los ed areas such a s unv entil ated ga rages, u tility roo ms or p arki ng area s be cause of the da nger of car bon monoxi de (CO) pois oning res ult ...

  • Goodman Mfg GPG13 - page 5

    5 Rooftop Installation • The unit may be installed directly on wood floors or on Class A, Class B, or Class C roof covering material. • T o avoid possible personal injury , a safe, flat surface for service personnel should be provided. R OOF C URB I NSTALLATIONS O NLY : • Sufficient structural support must be determined prior to locating and ...

  • Goodman Mfg GPG13 - page 6

    6 T RANSPORTATION D AMAGE Check the carton upon arrival for external damage. If damage is found, a request for inspection by carrier agent should be made in writing immediately . Carefully inspect the unit for damage including damage to the cabinetry . Any bolts or screws which may have loosened in transit must be re-tightened. In the event of dama ...

  • Goodman Mfg GPG13 - page 7

    7 Refer to the Proper Piping Practice drawing for the general layout at the unit. The following rules apply: 1. Use black iron pipe and fittings for the supply piping. The use of a flex connector and/or copper piping is permitted as long as it is in agreement with local codes. 2. Use pipe joint compound on male threads only . Pipe joint compound mu ...

  • Goodman Mfg GPG13 - page 8

    8 WARN I NG T O PREVENT PROPERTY DAMAGE O R SERIOUS P ERSONAL I NJURY DUE TO FIRE O R EXPLOSION C AUSED B Y A P RO PANE GAS LEAK, I NSTALL A GAS DETE CTING WARNING DEVICE. I F THE PROPANE GAS UNIT IS INSTALLED IN AN EXCAVATED AREA OR A CONFINE D SPACE, A WARNING DEVICE IS REQUIRED DUE TO: • P ROPANE GAS IS HEAVIE R THA N AIR AND ANY LEAKING G AS ...

  • Goodman Mfg GPG13 - page 9

    9 Electr ic al Po wer Di rec tly T o Ju ncti on B ox El ectr ic al Po wer Ro uted Thro ugh Bott om of Un it Note:Junction box locati on shown is optional and is for ill ustrati on purposes only. JUNCTION BOX Typical Electrical Wiring Unit Voltage U NIT V OLTAGE The unit transformer is factory connected for 230V operation. If the unit is to operate ...

  • Goodman Mfg GPG13 - page 10

    10 G Y W R R W Y1 G From Unit Y/Y 2 Y/Y 2 Typical 2-Stage Cool Thermostat and Unit 24 V Wiring Hookup *PG1360***1A Only CIRCULA TING AIR AND FIL TERS A IRFLOW C ONVERSION Units can easily be converted from horizontal to down- discharge airflow delivery . In down-discharge or high static installations, the installer should measure the total external ...

  • Goodman Mfg GPG13 - page 11

    11 VENTING NOTE: V enting is self-contained. Do not modify or block. F LUE H OOD I NSTALLATION Install the flue hood and bug screen prior to operation of the unit. T o install the flue hood cover and bug screen: 1. Remove the flue hood and bug screen from inside the heat exchanger compartment. 2. Slide the bug screen over the flanges of the flue ho ...

  • Goodman Mfg GPG13 - page 12

    12 NOTE: A 180-second anti-short cycle is integral to the control and prevents recycling of the compressor . F AN O NLY 1. Thermostat calls for F AN ONL Y by energizing “G”. 2. Approximately seven seconds later , the indoor fan starts. 3 . The indoor fan continues to run for approximately 60 seconds after “G” is de-energized. *PG13(48,60)** ...

  • Goodman Mfg GPG13 - page 13

    13 Gas Line Gas Shutoff Valv e Gas Line To Furnace Drip Leg Cap With Fitt ing Manometer Hose Manometer Open To Atmosphere Measuring Inlet Gas Pressure Alternate Method Manifold Pressure Check The gas valve has a tapped opening to facilitate measurement of the manifold pressure. A “U” T ube manometer having a scale range from 0 to 12 inches of w ...

  • Goodman Mfg GPG13 - page 14

    14 (switches 1 and 2) provides airflow adjustment for heating airflow . The “COOL” adjustment function (switches 5 and 6) provides airflow adjustments for cooling airflow . The “ADJUST” function (switches 7 and 8) will adjust the heating AND cooling airflow +10% or - 15%. The “DELA Y” function (switches 3 and 4) is not field adjustable. ...

  • Goodman Mfg GPG13 - page 15

    15 Dehumidification The GE ECM motor has the capability to provide increased dehumidification during cooling operation. This is accomplished by lowering the airflow to approximately 85% of the nominal cooling airflow . Example: Unit is operating at 1400 CFM and humidistat calls for dehumidification. Resulting airflow is 0.85* 1400 CFM = 1 190 CFM. ...

  • Goodman Mfg GPG13 - page 16

    16 A BNORMAL O PERATION - H EATING Internal Control Failure If the integrated ignition control in this unit encounters an internal fault, it will go into a “hard” lockout and turn off the diagnostic LED. If diagnostic LED indicates an internal fault, check power supply to unit for proper voltage, check all fuses, circuit breakers and wiring. Di ...

  • Goodman Mfg GPG13 - page 17

    17 MAINTENANCE Have the gas heating section of the unit checked at least once a year before the heating season begins, to be sure that the combustion air inlet and flue outlet hoods are not blocked by debris, which would prevent adequate combustion air and a properly operating vent system. F ILTER R EPLACEMENT OR C LEANING A return air filter is no ...

  • Goodman Mfg GPG13 - page 18

    18 M AIN B URNER F LAME (Q UALIFIED S ERVICER O NLY ) Flames should be stable, soft and blue (dust may cause orange tips but must not be yellow). The flames must extend directly outward from the burner without curling, floating or lifting off. Ch eck t h e b ur ne r fla m es fo r: 1. Good ad just me nt 2. Sta ble , soft and b lue 3. Not curling, fl ...

  • Goodman Mfg GPG13 - page 19

    19 IGNITION CONTROL DIAGNOSTIC INDICA TOR CHAR T HEA TING TIMING CHART 0 1 5 2 2 4 5 5 2 0 2 9 1 20 , 1 35 ,1 50 18 0* PG 13 4 8, 60 O NL Y Circul ator Bl ow er On Off Seconds Gas Val v e Ign iter I nduced Dr aft Bl ow er Therm ostat On Off On Off On Off On Off Leg en d: *P G10 ,12 , 24- 60 , *P G1 324- 4 2 *PG1348,60 100 % 50 % COOLING TIMING CHAR ...

  • Goodman Mfg GPG13 - page 20

    20 APPENDIX UNIT DIMENSIONS CO MBU STIO N AIR INLET S HOOD FLUE EXHAU ST CONT RO L W IR E EN TRANC E PO WER WIRE EN TRA N CE 7 7/8 7 5/16 SUCTIO N/LI QUID PRESSURE POR TS BEHIND COMPR ESSO R ACCESS PAN EL HEAT EXC HA NGE A CCESS PAN EL GA S SU PPLY ENTRANC E CO NDEN SATE DRAI N CON NE CTI ON 3/4" NPT F E MALE 16 1/8 19 1/8 EVAPORAT OR /CON TRO ...

  • Goodman Mfg GPG13 - page 21

    21 P GPG13(24,30,36,42)1A WIRING DIAGRAM TO THC MOT OR A LT . 3 S P E E D PU O R BL Y R B B R ECON PU R PU IIC GRD POW E R SU PPL Y R Y Y B B T2 L2 CC R T1 L1 CH OP TIONAL 208 -23 0 /1/ 60 B 3 NOTE 2 208 2 C 1 24V BL TRA NS 24 0 GR B PU R BL BL BL B BL B Y PU RC S COMP B B PU PU R R LS B BR CM BR BR EM 4 5 Y 12 3 LO W R BL MEDIUM OPTION AL 3 SPEE D ...

  • Goodman Mfg GPG13 - page 22

    22 GPG13(24,30,36,42)1A WIRING DIAGRAM HIGH VOL T AGE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MU L T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMA GE, PERSONAL INJURY OR DEA TH . B4312003 R EV . B Wiring is subject to change. Always refer to the wiring diagram on the unit for the m ...

  • Goodman Mfg GPG13 - page 23

    23 Y W IG N VM PU FS NOTE 3 B R W. R. (A LT.) HO NE YWE LL BL GAS VA LVE GV BL MV GA S VALVE GV PU MV PU RS Y PU PL Y BL NO TE 5 PS PU Y Y G PU PU ALS B Y PU O R PU BR Y PU CAP1 R R L1 UN US ED H EAT C OO L 6 4 5 O R R L2 PU 3 Y Y R 1 2 DI B B Y 12 9 R FS 10 7 11 8 ECON Y PU BL R B G Y W R Y RG Y W G W B Y G BL TH ERM OS T AT HEATER W1 HUM OFF ON D ...

  • Goodman Mfg GPG13 - page 24

    24 NOTE 6 WW Y Y BL C W G R W G R PU BL Y G R Y1 C Y2 G R THC- NO ECON OM IZ ER NOTE 5 PL NOTE 3 NOTE 2 NOTE 5 NOTE 4 2 ST AGE COOLING THC -WI TH ECO N OM I ZER O P TI ON BL PU C Y1 R G W R G W PS TROUBLES HOO TING THIS APPLI ANCE . STAT US LIGH T CODES ARE AS FOLLOWS : THE STATUS L IGHT ON T HE FURNACE CON TROL M AY B E USED AS A G UIDE TO CC STIC ...

  • Goodman Mfg GPG13 - page 25

    25 Y W IGN VM PU FS NOTE 3 B R W. R. (ALT.) HONEYWEL L BL GAS VA LVE GV BL MV GAS VALVE GV PU MV PU RS Y PU PL Y BL NOTE 5 PS PU Y Y G PU PU ALS B Y PU O R PU BR Y PU CAP1 R R L1 UNU SED HEA T COOL 6 4 5 O R R L2 PU 3 Y Y R 1 2 DI B B Y 12 9 R FS 10 7 11 8 ECON Y PU BL R B G Y W R Y R G YW G W B Y G BL TH ER MOS T AT HEAT ER W1 HU M OFF ON DIP S WI ...

  • Goodman Mfg GPG13 - page 26

    26 NOTE 6 WW Y1 PU Y Y2 W G R W G R PU BL Y G R Y1 C Y2 G R THC- NO ECONO M IZ ER NOTE 5 PL NOTE 3 NOTE 2 NOTE 5 NOTE 4 THC-WITH ECONOMIZER BL C STRIP PED L EAD FROM TER MINAL BLOC K FROM E CON. PLU G STRIP PED L EAD PS TROUBLESH OOT I NG THIS APPLI ANCE . STATUS LI GHT CODES ARE AS FOLLO WS: THE STA T US LI GHT ON T HE F URNACE CON TROL MAY BE USE ...

  • Goodman Mfg GPG13 - page 27

    27 GPG13(36)3A WIRING DIAGRAM MV MV RS PS AL S MOT OR 10 7 4 1 11 12 89 2 56 3 DI L1 COOL HE AT UNUS ED L2 LS T3 T1 T2 L1 T1 L2 T2 T3 L3 3 SPEED PU RD IG N FS BL PU PU BL PU PU YL GR BL YL PU YL YL BL RD GR WH PU YL YL PU BL BK BR RD OR RD FS RD BK BL RD BR BK RD RD PU PU BK BK PU BK BL BK BL BL BL RD PU BK BL BK BK BK YL YL RD RD PU ECON RD BK BL ...

  • Goodman Mfg GPG13 - page 28

    28 GPG13(36)3A WIRING DIAGRAM Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MU L T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMA GE, PERSONAL INJURY OR DEA TH . FROM ...

  • Goodman Mfg GPG13 - page 29

    29 GPG13(48,60)3A WIRING DIAGRAM RD BL YL WH GR YL YL WH YL RD GR YL BL RD RD BK PU BR PU BL BK RD PU BK PU BK YL BL PU PU YL YL RD RD RD PU BR BL PU BL YL PU GR PU YL BL YL BK BK BK BK YL YL BL BL RD RD OR RD WH RD BL PU RD BK PU RD RD RD BL BL BL BL OR RD WH BK BK BR BR BK PU PU BL RD PU Y L BL BL BL YL WH BL WH YL YL GR RD YL YL WH WH RD TO T HE ...

  • Goodman Mfg GPG13 - page 30

    30 GPG13(48,60)3A WIRING DIAGRAM NOTES EVAPORATO R MOTOR EM RS ROL LOUT S WIT CH TRA N SFORMER TR FL AM E SENS OR INTEG RATED I GNITION CO NT RO L LI MIT SW IT CH FEMA LE P LUG / CONNECT O R PR ES SU R E SW I TC H EQUIPME NT GROUND IIC IGN LS PLF PS IGN ITOR GND FS GV GAS V ALV E AUXILLA RY LIMIT SWITCH CONDENSER MOTOR CONTA CTO R CRANK CA S E HEA ...

  • Goodman Mfg GPG13 - page 31

    31 GPG13(36)4A WIRING DIAGRAM Y2 YL PU BL BK RD BL YL PU YL BL PU PU NO TE 4 PLF YL PU YL GR RD/Y L BK PU BK BR BR BR FC BK PU BK WH DI BR GR Y1 W YG CR RD OR BL BL BL YL PU BL RD GR WH L2 BL HEAT CO OL UNUS E D L1 FC GR RD RD BL BL WH YL YL BL PU RD FS RD YL 6 5 4 RD RD 1 3 2 GR 10 7 9 12 8 11 EC ON YL RD OR BK RD RD RD RD PU BL BL BL BK BK PU GR ...

  • Goodman Mfg GPG13 - page 32

    32 GPG13(36)4A WIRING DIAGRAM NOTE 4 NOTE 5 TR W IT H ECO NOM IZ ER OP T I O N BL PU RD GR WH GR RD YL BL NO EC ON O MIZ ER WH BL R C Y G W G R C Y W GR RD YL PU 2 ST AG E C OO LI NG WH C G R Y2 Y1 W NOTE 5 CH E CK EQUIP . STATUS STATUS L IGHT FAULT IN TE RNAL C ONTR OL NO P O WE R O R NO RM A L O PERA T IO N IG NI T ION FAIL URE SWI TCH OPE N SWI ...

  • Goodman Mfg GPG13 - page 33

    33 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPG13(48,60)4A WIRING DIAGRAM RD BL Y L WH GR YL YL WH YL RD GR YL BL RD RD BK PU BR PU BL BK RD PU BK PU BK YL BL PU PU YL YL RD RD RD PU BR BL PU BL YL PU GR PU YL BL YL BK BK BK BK YL YL RD RD BL RD OR RD WH BL PU RD BK PU RD RD RD BL B ...

  • Goodman Mfg GPG13 - page 34

    34 GPG13(48,60)4A WIRING DIAGRAM NOTES EVAPORATOR MOTOR EM RS ROLLOU T SWITCH TRANS FO R MER TR FL AM E SENS O R INTEGRA TED I GNITIO N CONT ROL LI MIT SW IT CH F E M A L E P L UG / C O NN E CT O R PRESSURE S WITCH EQUIPMENT GRO UND IIC IG N LS PL F PS IG NITOR GND FS GV GAS VALVE AUXILLARY LI MIT SWIT CH COND E NS ER M O TOR CONTA CT OR CRANKCASE ...

  • Goodman Mfg GPG13 - page 35

    35 GPG13(48,60)1B WIRING DIAGRAM RD BL Y L WH GR YL YL WH YL RD GR YL BL RD RD BK PU BR PU BL BK RD PU BK PU BK YL BL PU PU YL YL RD RD RD PU BR BL PU BL YL PU GR PU YL BL YL BK BK BK BK YL YL BL BL RD RD OR RD WH RD BL PU RD BK P U RD RD RD BL BL BL BL OR RD WH BR BR BK PU PU BL RD PU Y L BL BL BL YL WH BL WH YL YL GR RD YL YL WH WH RD FC H YL YL ...

  • Goodman Mfg GPG13 - page 36

    36 NO TE S EVAPORATOR M OT OR EM RS RO LL OU T SWI T CH TRANSFORMER TR FLAME SEN SO R INTEGRATED I GNITION CONTROL LIMI T S W I T C H FEMALE PL U G/CO NNECTOR PRESSURE SWITCH EQUIPMENT GRO UN D II C IGN LS PL F PS IGNIT OR GND FS GV GAS VALVE AUXILLARY L IMIT SWI T CH CONDEN SER MO TOR CONT ACT OR CRANKCASE HEATER CO M PONE N T LE G EN D CM C CH AL ...

  • Goodman Mfg GPG13 - page 37

    37 RECOMMENDED FIL TER SIZES UNIT 2 Ton 2 1/2 Ton 3 Ton 3 1/2 / 4 Ton 5 Ton Min. Filter Size (1)20 x 20 x 1 (1)20 x 25 x 1 (1)25 x 25 x1 (2)20 x 20 x 1 (2)20 x 25 x 1 MINIMUM CLEARANCES - NOTE: Roof overhang should be no more than 36". 3" MI N 12" MIN 12" MIN 36" M IN (FOR SERVI CE ) . 48" M IN ...

  • Goodman Mfg GPG13 - page 38

    38 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Goodman Mfg GPG13 - page 39

    39 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Goodman Mfg GPG13 - page 40

    40 NOTE: SPECIFICA TIONS AND PERFORMANCE DA T A LISTED HEREIN ARE SUBJECT T O CHANGE WITHOUT NOTICE Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficiency . We have designed these units to significantly reduce the most frequent causes of product failure. T ...

Fabricant Goodman Mfg Catégorie Gas Heater

Les documents que nous recevons du fabricant de l'appareilGoodman Mfg GPG13 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goodman Mfg
- manuels d’utilisations GPG13
- fiches produit Goodman Mfg
- dépliants
- ou étiquettes-énergie Goodman Mfg GPG13
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goodman Mfg GPG13.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goodman Mfg GPG13, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goodman Mfg GPG13. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goodman Mfg GPG13.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goodman Mfg GPG13, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goodman Mfg GPG13 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goodman Mfg GPG13.

Le manuel d’utilisation complet Goodman Mfg, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goodman Mfg GPG13 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goodman Mfg GPG13, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoodman Mfg GPG13 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goodman Mfg GPG13 - qui devraient nous aider dans les premières étapes lors de l'utilisation Goodman Mfg GPG13
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goodman Mfg GPG13
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goodman Mfg GPG13 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goodman Mfg GPG13?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goodman Mfg GPG13, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goodman Mfg GPG13 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)