Manuale per l’uso Goodman Mfg GPG13

40 pagine 1.29 mb
Scarica

Vai alla pagina of 40

Summary
  • Goodman Mfg GPG13 - page 1

    Affix this manual and Users Information Manual adjacent to the unit. INST ALLA TION & OPERA TING INSTRUCTIONS for GPG13 SINGLE P ACKAGE GAS-ELECTRIC HEA TING & COOLING UNIT C US ® Goodman Manufacturing Company , L.P . IO-288B 5151 San Felipe, Suite 500, Houston, TX 77056 07/08 www .goodmanmfg.com © 2005 - 2008 Goodman Manufacturing Compan ...

  • Goodman Mfg GPG13 - page 2

    2 INDEX Replacement Part s ............................................................................................................................................................. 3 O RDERING P ARTS .............................................................................................................................................. 3 S ...

  • Goodman Mfg GPG13 - page 3

    3 REPLACEMENT PAR TS O RDERING P ARTS When reporting shortages or damages, or ordering repair parts, give the complete unit model and serial numbers as stamped on the unit’s nameplate. Replacement part s for this appliance are available through your contractor or local distributor . For the location of your nearest distributor , consult the white ...

  • Goodman Mfg GPG13 - page 4

    4 CA RBON M ONOXIDE POISON ING HA Z A RD B10259-216 Carbo n mon oxi de pr o duci ng devi ces (s uc h as an a uto mob ile, s pac e heater , gas wat er heat er, etc.) shoul d not be op er ated i n enc los ed areas such a s unv entil ated ga rages, u tility roo ms or p arki ng area s be cause of the da nger of car bon monoxi de (CO) pois oning res ult ...

  • Goodman Mfg GPG13 - page 5

    5 Rooftop Installation • The unit may be installed directly on wood floors or on Class A, Class B, or Class C roof covering material. • T o avoid possible personal injury , a safe, flat surface for service personnel should be provided. R OOF C URB I NSTALLATIONS O NLY : • Sufficient structural support must be determined prior to locating and ...

  • Goodman Mfg GPG13 - page 6

    6 T RANSPORTATION D AMAGE Check the carton upon arrival for external damage. If damage is found, a request for inspection by carrier agent should be made in writing immediately . Carefully inspect the unit for damage including damage to the cabinetry . Any bolts or screws which may have loosened in transit must be re-tightened. In the event of dama ...

  • Goodman Mfg GPG13 - page 7

    7 Refer to the Proper Piping Practice drawing for the general layout at the unit. The following rules apply: 1. Use black iron pipe and fittings for the supply piping. The use of a flex connector and/or copper piping is permitted as long as it is in agreement with local codes. 2. Use pipe joint compound on male threads only . Pipe joint compound mu ...

  • Goodman Mfg GPG13 - page 8

    8 WARN I NG T O PREVENT PROPERTY DAMAGE O R SERIOUS P ERSONAL I NJURY DUE TO FIRE O R EXPLOSION C AUSED B Y A P RO PANE GAS LEAK, I NSTALL A GAS DETE CTING WARNING DEVICE. I F THE PROPANE GAS UNIT IS INSTALLED IN AN EXCAVATED AREA OR A CONFINE D SPACE, A WARNING DEVICE IS REQUIRED DUE TO: • P ROPANE GAS IS HEAVIE R THA N AIR AND ANY LEAKING G AS ...

  • Goodman Mfg GPG13 - page 9

    9 Electr ic al Po wer Di rec tly T o Ju ncti on B ox El ectr ic al Po wer Ro uted Thro ugh Bott om of Un it Note:Junction box locati on shown is optional and is for ill ustrati on purposes only. JUNCTION BOX Typical Electrical Wiring Unit Voltage U NIT V OLTAGE The unit transformer is factory connected for 230V operation. If the unit is to operate ...

  • Goodman Mfg GPG13 - page 10

    10 G Y W R R W Y1 G From Unit Y/Y 2 Y/Y 2 Typical 2-Stage Cool Thermostat and Unit 24 V Wiring Hookup *PG1360***1A Only CIRCULA TING AIR AND FIL TERS A IRFLOW C ONVERSION Units can easily be converted from horizontal to down- discharge airflow delivery . In down-discharge or high static installations, the installer should measure the total external ...

  • Goodman Mfg GPG13 - page 11

    11 VENTING NOTE: V enting is self-contained. Do not modify or block. F LUE H OOD I NSTALLATION Install the flue hood and bug screen prior to operation of the unit. T o install the flue hood cover and bug screen: 1. Remove the flue hood and bug screen from inside the heat exchanger compartment. 2. Slide the bug screen over the flanges of the flue ho ...

  • Goodman Mfg GPG13 - page 12

    12 NOTE: A 180-second anti-short cycle is integral to the control and prevents recycling of the compressor . F AN O NLY 1. Thermostat calls for F AN ONL Y by energizing “G”. 2. Approximately seven seconds later , the indoor fan starts. 3 . The indoor fan continues to run for approximately 60 seconds after “G” is de-energized. *PG13(48,60)** ...

  • Goodman Mfg GPG13 - page 13

    13 Gas Line Gas Shutoff Valv e Gas Line To Furnace Drip Leg Cap With Fitt ing Manometer Hose Manometer Open To Atmosphere Measuring Inlet Gas Pressure Alternate Method Manifold Pressure Check The gas valve has a tapped opening to facilitate measurement of the manifold pressure. A “U” T ube manometer having a scale range from 0 to 12 inches of w ...

  • Goodman Mfg GPG13 - page 14

    14 (switches 1 and 2) provides airflow adjustment for heating airflow . The “COOL” adjustment function (switches 5 and 6) provides airflow adjustments for cooling airflow . The “ADJUST” function (switches 7 and 8) will adjust the heating AND cooling airflow +10% or - 15%. The “DELA Y” function (switches 3 and 4) is not field adjustable. ...

  • Goodman Mfg GPG13 - page 15

    15 Dehumidification The GE ECM motor has the capability to provide increased dehumidification during cooling operation. This is accomplished by lowering the airflow to approximately 85% of the nominal cooling airflow . Example: Unit is operating at 1400 CFM and humidistat calls for dehumidification. Resulting airflow is 0.85* 1400 CFM = 1 190 CFM. ...

  • Goodman Mfg GPG13 - page 16

    16 A BNORMAL O PERATION - H EATING Internal Control Failure If the integrated ignition control in this unit encounters an internal fault, it will go into a “hard” lockout and turn off the diagnostic LED. If diagnostic LED indicates an internal fault, check power supply to unit for proper voltage, check all fuses, circuit breakers and wiring. Di ...

  • Goodman Mfg GPG13 - page 17

    17 MAINTENANCE Have the gas heating section of the unit checked at least once a year before the heating season begins, to be sure that the combustion air inlet and flue outlet hoods are not blocked by debris, which would prevent adequate combustion air and a properly operating vent system. F ILTER R EPLACEMENT OR C LEANING A return air filter is no ...

  • Goodman Mfg GPG13 - page 18

    18 M AIN B URNER F LAME (Q UALIFIED S ERVICER O NLY ) Flames should be stable, soft and blue (dust may cause orange tips but must not be yellow). The flames must extend directly outward from the burner without curling, floating or lifting off. Ch eck t h e b ur ne r fla m es fo r: 1. Good ad just me nt 2. Sta ble , soft and b lue 3. Not curling, fl ...

  • Goodman Mfg GPG13 - page 19

    19 IGNITION CONTROL DIAGNOSTIC INDICA TOR CHAR T HEA TING TIMING CHART 0 1 5 2 2 4 5 5 2 0 2 9 1 20 , 1 35 ,1 50 18 0* PG 13 4 8, 60 O NL Y Circul ator Bl ow er On Off Seconds Gas Val v e Ign iter I nduced Dr aft Bl ow er Therm ostat On Off On Off On Off On Off Leg en d: *P G10 ,12 , 24- 60 , *P G1 324- 4 2 *PG1348,60 100 % 50 % COOLING TIMING CHAR ...

  • Goodman Mfg GPG13 - page 20

    20 APPENDIX UNIT DIMENSIONS CO MBU STIO N AIR INLET S HOOD FLUE EXHAU ST CONT RO L W IR E EN TRANC E PO WER WIRE EN TRA N CE 7 7/8 7 5/16 SUCTIO N/LI QUID PRESSURE POR TS BEHIND COMPR ESSO R ACCESS PAN EL HEAT EXC HA NGE A CCESS PAN EL GA S SU PPLY ENTRANC E CO NDEN SATE DRAI N CON NE CTI ON 3/4" NPT F E MALE 16 1/8 19 1/8 EVAPORAT OR /CON TRO ...

  • Goodman Mfg GPG13 - page 21

    21 P GPG13(24,30,36,42)1A WIRING DIAGRAM TO THC MOT OR A LT . 3 S P E E D PU O R BL Y R B B R ECON PU R PU IIC GRD POW E R SU PPL Y R Y Y B B T2 L2 CC R T1 L1 CH OP TIONAL 208 -23 0 /1/ 60 B 3 NOTE 2 208 2 C 1 24V BL TRA NS 24 0 GR B PU R BL BL BL B BL B Y PU RC S COMP B B PU PU R R LS B BR CM BR BR EM 4 5 Y 12 3 LO W R BL MEDIUM OPTION AL 3 SPEE D ...

  • Goodman Mfg GPG13 - page 22

    22 GPG13(24,30,36,42)1A WIRING DIAGRAM HIGH VOL T AGE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MU L T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMA GE, PERSONAL INJURY OR DEA TH . B4312003 R EV . B Wiring is subject to change. Always refer to the wiring diagram on the unit for the m ...

  • Goodman Mfg GPG13 - page 23

    23 Y W IG N VM PU FS NOTE 3 B R W. R. (A LT.) HO NE YWE LL BL GAS VA LVE GV BL MV GA S VALVE GV PU MV PU RS Y PU PL Y BL NO TE 5 PS PU Y Y G PU PU ALS B Y PU O R PU BR Y PU CAP1 R R L1 UN US ED H EAT C OO L 6 4 5 O R R L2 PU 3 Y Y R 1 2 DI B B Y 12 9 R FS 10 7 11 8 ECON Y PU BL R B G Y W R Y RG Y W G W B Y G BL TH ERM OS T AT HEATER W1 HUM OFF ON D ...

  • Goodman Mfg GPG13 - page 24

    24 NOTE 6 WW Y Y BL C W G R W G R PU BL Y G R Y1 C Y2 G R THC- NO ECON OM IZ ER NOTE 5 PL NOTE 3 NOTE 2 NOTE 5 NOTE 4 2 ST AGE COOLING THC -WI TH ECO N OM I ZER O P TI ON BL PU C Y1 R G W R G W PS TROUBLES HOO TING THIS APPLI ANCE . STAT US LIGH T CODES ARE AS FOLLOWS : THE STATUS L IGHT ON T HE FURNACE CON TROL M AY B E USED AS A G UIDE TO CC STIC ...

  • Goodman Mfg GPG13 - page 25

    25 Y W IGN VM PU FS NOTE 3 B R W. R. (ALT.) HONEYWEL L BL GAS VA LVE GV BL MV GAS VALVE GV PU MV PU RS Y PU PL Y BL NOTE 5 PS PU Y Y G PU PU ALS B Y PU O R PU BR Y PU CAP1 R R L1 UNU SED HEA T COOL 6 4 5 O R R L2 PU 3 Y Y R 1 2 DI B B Y 12 9 R FS 10 7 11 8 ECON Y PU BL R B G Y W R Y R G YW G W B Y G BL TH ER MOS T AT HEAT ER W1 HU M OFF ON DIP S WI ...

  • Goodman Mfg GPG13 - page 26

    26 NOTE 6 WW Y1 PU Y Y2 W G R W G R PU BL Y G R Y1 C Y2 G R THC- NO ECONO M IZ ER NOTE 5 PL NOTE 3 NOTE 2 NOTE 5 NOTE 4 THC-WITH ECONOMIZER BL C STRIP PED L EAD FROM TER MINAL BLOC K FROM E CON. PLU G STRIP PED L EAD PS TROUBLESH OOT I NG THIS APPLI ANCE . STATUS LI GHT CODES ARE AS FOLLO WS: THE STA T US LI GHT ON T HE F URNACE CON TROL MAY BE USE ...

  • Goodman Mfg GPG13 - page 27

    27 GPG13(36)3A WIRING DIAGRAM MV MV RS PS AL S MOT OR 10 7 4 1 11 12 89 2 56 3 DI L1 COOL HE AT UNUS ED L2 LS T3 T1 T2 L1 T1 L2 T2 T3 L3 3 SPEED PU RD IG N FS BL PU PU BL PU PU YL GR BL YL PU YL YL BL RD GR WH PU YL YL PU BL BK BR RD OR RD FS RD BK BL RD BR BK RD RD PU PU BK BK PU BK BL BK BL BL BL RD PU BK BL BK BK BK YL YL RD RD PU ECON RD BK BL ...

  • Goodman Mfg GPG13 - page 28

    28 GPG13(36)3A WIRING DIAGRAM Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MU L T IPL E POW ER SOUR CES MA Y BE P RESENT . F AILURE TO DO SO MA Y CAUS E PROP ERTY DAMA GE, PERSONAL INJURY OR DEA TH . FROM ...

  • Goodman Mfg GPG13 - page 29

    29 GPG13(48,60)3A WIRING DIAGRAM RD BL YL WH GR YL YL WH YL RD GR YL BL RD RD BK PU BR PU BL BK RD PU BK PU BK YL BL PU PU YL YL RD RD RD PU BR BL PU BL YL PU GR PU YL BL YL BK BK BK BK YL YL BL BL RD RD OR RD WH RD BL PU RD BK PU RD RD RD BL BL BL BL OR RD WH BK BK BR BR BK PU PU BL RD PU Y L BL BL BL YL WH BL WH YL YL GR RD YL YL WH WH RD TO T HE ...

  • Goodman Mfg GPG13 - page 30

    30 GPG13(48,60)3A WIRING DIAGRAM NOTES EVAPORATO R MOTOR EM RS ROL LOUT S WIT CH TRA N SFORMER TR FL AM E SENS OR INTEG RATED I GNITION CO NT RO L LI MIT SW IT CH FEMA LE P LUG / CONNECT O R PR ES SU R E SW I TC H EQUIPME NT GROUND IIC IGN LS PLF PS IGN ITOR GND FS GV GAS V ALV E AUXILLA RY LIMIT SWITCH CONDENSER MOTOR CONTA CTO R CRANK CA S E HEA ...

  • Goodman Mfg GPG13 - page 31

    31 GPG13(36)4A WIRING DIAGRAM Y2 YL PU BL BK RD BL YL PU YL BL PU PU NO TE 4 PLF YL PU YL GR RD/Y L BK PU BK BR BR BR FC BK PU BK WH DI BR GR Y1 W YG CR RD OR BL BL BL YL PU BL RD GR WH L2 BL HEAT CO OL UNUS E D L1 FC GR RD RD BL BL WH YL YL BL PU RD FS RD YL 6 5 4 RD RD 1 3 2 GR 10 7 9 12 8 11 EC ON YL RD OR BK RD RD RD RD PU BL BL BL BK BK PU GR ...

  • Goodman Mfg GPG13 - page 32

    32 GPG13(36)4A WIRING DIAGRAM NOTE 4 NOTE 5 TR W IT H ECO NOM IZ ER OP T I O N BL PU RD GR WH GR RD YL BL NO EC ON O MIZ ER WH BL R C Y G W G R C Y W GR RD YL PU 2 ST AG E C OO LI NG WH C G R Y2 Y1 W NOTE 5 CH E CK EQUIP . STATUS STATUS L IGHT FAULT IN TE RNAL C ONTR OL NO P O WE R O R NO RM A L O PERA T IO N IG NI T ION FAIL URE SWI TCH OPE N SWI ...

  • Goodman Mfg GPG13 - page 33

    33 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPG13(48,60)4A WIRING DIAGRAM RD BL Y L WH GR YL YL WH YL RD GR YL BL RD RD BK PU BR PU BL BK RD PU BK PU BK YL BL PU PU YL YL RD RD RD PU BR BL PU BL YL PU GR PU YL BL YL BK BK BK BK YL YL RD RD BL RD OR RD WH BL PU RD BK PU RD RD RD BL B ...

  • Goodman Mfg GPG13 - page 34

    34 GPG13(48,60)4A WIRING DIAGRAM NOTES EVAPORATOR MOTOR EM RS ROLLOU T SWITCH TRANS FO R MER TR FL AM E SENS O R INTEGRA TED I GNITIO N CONT ROL LI MIT SW IT CH F E M A L E P L UG / C O NN E CT O R PRESSURE S WITCH EQUIPMENT GRO UND IIC IG N LS PL F PS IG NITOR GND FS GV GAS VALVE AUXILLARY LI MIT SWIT CH COND E NS ER M O TOR CONTA CT OR CRANKCASE ...

  • Goodman Mfg GPG13 - page 35

    35 GPG13(48,60)1B WIRING DIAGRAM RD BL Y L WH GR YL YL WH YL RD GR YL BL RD RD BK PU BR PU BL BK RD PU BK PU BK YL BL PU PU YL YL RD RD RD PU BR BL PU BL YL PU GR PU YL BL YL BK BK BK BK YL YL BL BL RD RD OR RD WH RD BL PU RD BK P U RD RD RD BL BL BL BL OR RD WH BR BR BK PU PU BL RD PU Y L BL BL BL YL WH BL WH YL YL GR RD YL YL WH WH RD FC H YL YL ...

  • Goodman Mfg GPG13 - page 36

    36 NO TE S EVAPORATOR M OT OR EM RS RO LL OU T SWI T CH TRANSFORMER TR FLAME SEN SO R INTEGRATED I GNITION CONTROL LIMI T S W I T C H FEMALE PL U G/CO NNECTOR PRESSURE SWITCH EQUIPMENT GRO UN D II C IGN LS PL F PS IGNIT OR GND FS GV GAS VALVE AUXILLARY L IMIT SWI T CH CONDEN SER MO TOR CONT ACT OR CRANKCASE HEATER CO M PONE N T LE G EN D CM C CH AL ...

  • Goodman Mfg GPG13 - page 37

    37 RECOMMENDED FIL TER SIZES UNIT 2 Ton 2 1/2 Ton 3 Ton 3 1/2 / 4 Ton 5 Ton Min. Filter Size (1)20 x 20 x 1 (1)20 x 25 x 1 (1)25 x 25 x1 (2)20 x 20 x 1 (2)20 x 25 x 1 MINIMUM CLEARANCES - NOTE: Roof overhang should be no more than 36". 3" MI N 12" MIN 12" MIN 36" M IN (FOR SERVI CE ) . 48" M IN ...

  • Goodman Mfg GPG13 - page 38

    38 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Goodman Mfg GPG13 - page 39

    39 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Goodman Mfg GPG13 - page 40

    40 NOTE: SPECIFICA TIONS AND PERFORMANCE DA T A LISTED HEREIN ARE SUBJECT T O CHANGE WITHOUT NOTICE Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficiency . We have designed these units to significantly reduce the most frequent causes of product failure. T ...

Fabbricante Goodman Mfg Categoria Gas Heater

I documenti che otteniamo dal fabbricante del dispositivoGoodman Mfg GPG13 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Goodman Mfg
- manuali per l’uso GPG13
- schede prodotto Goodman Mfg
- opuscoli
- o etichette energetiche Goodman Mfg GPG13
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Goodman Mfg GPG13.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Goodman Mfg GPG13, manuali di manutenzione, brevi manuali o manuali utente Goodman Mfg GPG13. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Goodman Mfg GPG13.

Manuali per l’uso simili

Manuale completo del dispositivo Goodman Mfg GPG13, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Goodman Mfg GPG13 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Goodman Mfg GPG13.

Il manuale per l’uso completo Goodman Mfg, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Goodman Mfg GPG13 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Goodman Mfg GPG13, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Goodman Mfg GPG13 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Goodman Mfg GPG13 - che ci dovrebbe aiutare nei primi passi durante l'uso Goodman Mfg GPG13
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Goodman Mfg GPG13
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Goodman Mfg GPG13 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Goodman Mfg GPG13?

Utilizza il modulo sottostante

Se non hai risolto il problema con Goodman Mfg GPG13 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Goodman Mfg GPG13 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)