  • Bradford-White Corp MI404T*F(BN - page 1

    SERVICE MANU AL Flammable V apor Ignition Resistant W ater Heater Troubleshooting Guide and Instruction f or Service (T o be perf ormed ONL Y b y qualified service providers) F or the Bradford White Defender Safety System ™ Models: MI30T*F(BN,CX)2 MI30S*F(BN,CX)2 MI303T*F(BN,CX)2 MI40T*F(BN,CX)2 MI403S*F(BN,CX)2 MI404T*F(BN,CX)2 MI503*F(BN,CX)2 M ...

  • Bradford-White Corp MI404T*F(BN - page 2

    2 Flammable V apor Ignition Resistant W ater Heater T able of Cont ents P ag e Service Pr ocedur e Introduction 3 - - - T rouble shooting Char t 4 - - - Inner Door Gask et Remo val, Inspection, Replacement and Installation 5 RG-I Thermocouple T esting and Replacement 8 RG-II Pilot Assembly Inspection Cleaning and Replacement 1 0 RG-III Piezo Ignite ...

  • Bradford-White Corp MI404T*F(BN - page 3

    3 Introduction The Br adf or d Whit e DEFENDER Safety Sy s t em ™ The Bradf ord Whit e DEFENDER Saf ety Sys t em TM was designed t o resis t t he ignition of flammable vapors that can occur outside of the water heater . Use and installation are nearly identical to previous versions of atmospherically f ired and vent ed wat er heaters. A number of ...

  • Bradford-White Corp MI404T*F(BN - page 4

    4 S YMPT OM PR OB ABLE C A USE C ORRECTIVE A CTION Pilot Will Not Light 1 . No incoming gas or too low gas pressure. 2. Gas control knob set to wrong position. 3. Pilot light button not being fully depressed when attempting to light pilot. 4. Pilot orif ice or pilot tube is obstructed or kinked. 5. Pilot electrode not sparking to pilot. 6. Piezo ig ...

  • Bradford-White Corp MI404T*F(BN - page 5

    SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation Inner Door Remo v al Pr ocedur e St ep 1 . R otate knob of the combination thermostat/g as valve to the “OFF” position. St ep 2. R emov e outer jack et burner access door St ep 3. Inner Door Remov al. a) Disconnect resettable thermal switc h wire le ...

  • Bradford-White Corp MI404T*F(BN - page 6

    6 SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation Ins t allation of Inner Door wit h Gask et St ep 7 . Clean an y residual gask et residue or other debris from combustion chamber sur face before installing the inner door/gask et assembly . St ep 8. Place the lef t side inner door into position fir st ...

  • Bradford-White Corp MI404T*F(BN - page 7

    7 SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation St ep 1 0. Firmly place right side inner door flange agains t the lef t side inner door f lange and secure with two 1/4” drive screws from step 3c. DO NOT O VER TIGHTEN SCREWS. St ep 1 1 . Align right side inner door to combustion chamber and verify ...

  • Bradford-White Corp MI404T*F(BN - page 8

    8 SERVICE PROCEDURE RG-II Thermocouple T esting and Replacement Closed Cir cuit Ther mocouple T es ting St ep 1 . Disconnect thermocouple from combination thermostat/g as valve. St ep 2. Connect a thermocouple adapter (BWC P/N 239-44642-00, R ober tshaw P/N 75036) at the thermocouple location in the combination thermostat/g as valve. St ep 3. R eco ...

  • Bradford-White Corp MI404T*F(BN - page 9

    9 SERVICE PROCEDURE RG-II Thermocouple T esting and Replacement Ther mocouple R eplacement St ep 1 . T ur n of f gas supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. Remo ve outer jack et door . St ep 3. R emov e right side of inner door per SERVICE PROCEDURE RG-I, st eps 3a through 3c. St e ...

  • Bradford-White Corp MI404T*F(BN - page 10

    10 SERVICE PROCEDURE RG-III Pilot Assembly Inspection, Cleaning and R eplacement Pilot/Electr ode Assembly Inspection, Cleaning and Replacement St ep 1 . T ur n of f gas supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. Remo ve outer jack et door . St ep 3. R emov e right side of inner door p ...

  • Bradford-White Corp MI404T*F(BN - page 11

    11 SERVICE PROCEDURE RG-IV Piezo Igniter , Electrode T esting and Replacement Piezo Ignit er , Electrode T esting and R eplacement With the pilot not in operation (no pilot f lame) y ou can check the Piezo and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action. St ep 1 . Remo ve outer ja ...

  • Bradford-White Corp MI404T*F(BN - page 12

    Combination Ther mos t at/Gas V al v e T esting and R eplacement The combination thermostat/gas valve is a non repairable device. If trouble shooting has determined a problem with the combination thermostat/g as valve, it must be replaced. If the bur ner and/or pilot do not function, service chec ks for gas pressure, thermocouple output, magnet ass ...

  • Bradford-White Corp MI404T*F(BN - page 13

    THERMOC OUPLE TES TIN G See SERVICE PROCEDURE II MA GNET ASSEMBL Y TES TIN G St ep 1 . Disconnect thermocouple from combination thermostat/g as valve. St ep 2. Connect a thermocouple adapter (BWC P/N 239-44642-00, Robertshaw P/N 75036) at the thermocouple location in the combination thermostat/g as valve. St ep 3. R econnect thermocouple to adapter ...

  • Bradford-White Corp MI404T*F(BN - page 14

    C OMBIN A TION THERMOS T A T/GAS V AL VE REPL A CEMENT St ep 1 . R otate knob of the combination thermostat/g as valve to the “OFF” position. St ep 2. T ur n of f gas supply to water heater . St ep 3. Disconnect gas supply line from combination thermostat/g as valve. St ep 4. T ur n of f water supply and drain water heater completely . St ep 5. ...

  • Bradford-White Corp MI404T*F(BN - page 15

    15 St ep 7 . R emov al of combination thermostat/g as valve. a) Disconnect main bur ner feedline (3/4” wrench), pilot tube (7/1 6" wrench) and thermocouple (3/8" wrench) from combination thermostat/g as valve & remov e from the combustion chamber . b) R emov e Piezo brack et with Piezo igniter (refer to SERVICE PROCEDURE RG-IV) from ...

  • Bradford-White Corp MI404T*F(BN - page 16

    St ep 9. R einstallation of inner door assembly . (cont.) b) Clean any gask et residue or other debris from combustion chamber surface before installing the inner door/gask et assembly . c) P osition thermocouple, pilot tube and Piezo wire against lef t side inner door flange gask et. DO N O T R OUTE THR OUGH R ADIUSED CHANNEL WITH FEEDLINE. Be sur ...

  • Bradford-White Corp MI404T*F(BN - page 17

    MAIN BURNER: Inspection, A djus tment, Cleaning and Replacement At periodic intervals (not more then 6 months) a visual inspection should be made of the main bur ner f or proper opera- tion and to insure no debris accumulating. Main burner should light smoothly from pilot and burn with a blue f lame with a minimum of yellow tips. St eel burner mode ...

  • Bradford-White Corp MI404T*F(BN - page 18

    MAIN BURNER: Inspection, A djus tment, Cleaning and Replacement (cont.) St ep 3. Full y inspect inner gask et per SERVICE PROCEDURE RG-I, st ep 4. Replace gask et if required follo wing SERVICE PROCEDURE I, st eps 5 & 6. St ep 4. Be cer tain that thermocouple, pilot tube and Piezo wire are routed b y inner door f lange as shown and Reinstall in ...

  • Bradford-White Corp MI404T*F(BN - page 19

    BURNER CLEANIN G (cont.) St ep 5. Disconnect (unscrew) main burner (stamped steel “B” bur ner) from main burner orif ice or on cast iron bur ners (“C” burner), loosen air shutter & disconnect (unscrew) feedline from burner . St ep 6. Remo ve main burner orif ice from feed line (1/2” wrench on steel burner , 3/8" wrench on cast ir ...

  • Bradford-White Corp MI404T*F(BN - page 20

    RESETT ABLE THERMAL SWIT C H C ONTINUIT Y TES TIN G St ep 1 . Remo ve outer jack et door . St ep 2. Disconnect wire leads from resettable thermal switc h. St ep 3. Using a multimeter capable of measuring continuity (Ohms), place one probe of meter on one of the brass connection tabs of the resettable thermal switch, and the remaining probe on the o ...

  • Bradford-White Corp MI404T*F(BN - page 21

    RESETT ABLE THERMAL SWIT C H REPL A CEMENT St ep 1 . R otate knob of combination thermostat gas valve to the of f position. St ep 2. Remo ve outer jack et door . St ep 3. Disconnect wire leads from resettable thermal switc h. St ep 4. R emov e resettable thermal switc h from inner door (Phillips screw driver). St ep 5. Place new resettable thermal ...

  • Bradford-White Corp MI404T*F(BN - page 22

    Scr eenLok Flame Ar r es t or Cleaning St ep 1 . R otate knob of combination thermostat gas valve to the of f position. St ep 2. Remo ve outer jack et door . St ep 3. Remo ve inner door per SERVICE PROCEDURE RG-I, st ep 3a through 3e. St ep 4. Disconnect main bur ner feed line (3/4 wrench), pilot tube (7/1 6 wrench) and thermocouple (3/8) wrench fr ...

  • Bradford-White Corp MI404T*F(BN - page 23

    23 Dip T ube Inspection and R eplacement St ep 1 . R otate knob of combination thermostat/gas valve to “OFF” position. St ep 2. T ur n of f c old water supply to heater . Connect hose to drain spigot of wat er heater and rout e to an open drain. Open a nearby hot water faucet to vent heater f or draining. Open drain spigot of water heater and a ...

  • Bradford-White Corp MI404T*F(BN - page 24

    24 Anode Inspection and R eplacement St ep 1 . T ur n of f water supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. T ur n of f c old water supply to heater . Connect hose to drain spigot of wat er heater and rout e to an open drain. Open a nearby hot water faucet to vent heater f or draining. ...

  • Bradford-White Corp MI404T*F(BN - page 25

    25 1 Draf t Hood 2 Hot Water Outlet/Anode 3 Cold Water Inlet T ube 4 Flue Baf f le 5 T&P Relief Valv e 6 Thermostat 7 Piezo Igniter 8 Brass Drain Valv e 9 Screw -#8- 1 8 x 3/4 Hex Washer Head 1 0 Screw -#1 0- 1 2 x 3/4 Hex Washer Head 1 1 Lef t Side Inner Door with Gasket 1 2 Complete Right Side Inner Door 1 2A Right Side Inner Door with Gasket ...

  • Bradford-White Corp MI404T*F(BN - page 26

    26 Notes ...

  • Bradford-White Corp MI404T*F(BN - page 27

    27 Notes ...

  • Bradford-White Corp MI404T*F(BN - page 28

    Sales/ 800-523-2931 Fax/ 215-641-1670 Technical Support/ 800-334-3393 Fax/ 269-795-1089 W arranty/ 800-531-2111 Fax/ 269-795-1089 International: T elephone/ 215-641-9400 T elefax/ 215-641-9750 Ambler , P A 888-538-7833 Fax on Demand: bradfor dwhite.com www. For U.S. and Canada field service, contact your professional installer or local Bradford Whi ...

Fabricant Bradford-White Corp Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilBradford-White Corp MI404T*F(BN peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bradford-White Corp
- manuels d’utilisations MI404T*F(BN
- fiches produit Bradford-White Corp
- dépliants
- ou étiquettes-énergie Bradford-White Corp MI404T*F(BN
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bradford-White Corp MI404T*F(BN.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bradford-White Corp MI404T*F(BN, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bradford-White Corp MI404T*F(BN. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bradford-White Corp MI404T*F(BN.

Manuel d’utilisation complet de l’appareil Bradford-White Corp MI404T*F(BN, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bradford-White Corp MI404T*F(BN par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bradford-White Corp MI404T*F(BN.

Le manuel d’utilisation complet Bradford-White Corp, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bradford-White Corp MI404T*F(BN - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bradford-White Corp MI404T*F(BN, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBradford-White Corp MI404T*F(BN qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bradford-White Corp MI404T*F(BN - qui devraient nous aider dans les premières étapes lors de l'utilisation Bradford-White Corp MI404T*F(BN
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bradford-White Corp MI404T*F(BN
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bradford-White Corp MI404T*F(BN dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bradford-White Corp MI404T*F(BN?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bradford-White Corp MI404T*F(BN, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bradford-White Corp MI404T*F(BN il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)