    SERVICE MANU AL Flammable V apor Ignition Resistant W ater Heater Troubleshooting Guide and Instruction f or Service (T o be perf ormed ONL Y b y qualified service providers) F or the Bradford White Defender Safety System ™ Models: MI30T*F(BN,CX)2 MI30S*F(BN,CX)2 MI303T*F(BN,CX)2 MI40T*F(BN,CX)2 MI403S*F(BN,CX)2 MI404T*F(BN,CX)2 MI503*F(BN,CX)2 M ...

  • Bradford-White Corp MI404T*F(BN - page 2

    2 Flammable V apor Ignition Resistant W ater Heater T able of Cont ents P ag e Service Pr ocedur e Introduction 3 - - - T rouble shooting Char t 4 - - - Inner Door Gask et Remo val, Inspection, Replacement and Installation 5 RG-I Thermocouple T esting and Replacement 8 RG-II Pilot Assembly Inspection Cleaning and Replacement 1 0 RG-III Piezo Ignite ...

  • Bradford-White Corp MI404T*F(BN - page 3

    3 Introduction The Br adf or d Whit e DEFENDER Safety Sy s t em ™ The Bradf ord Whit e DEFENDER Saf ety Sys t em TM was designed t o resis t t he ignition of flammable vapors that can occur outside of the water heater . Use and installation are nearly identical to previous versions of atmospherically f ired and vent ed wat er heaters. A number of ...

  • Bradford-White Corp MI404T*F(BN - page 4

    4 S YMPT OM PR OB ABLE C A USE C ORRECTIVE A CTION Pilot Will Not Light 1 . No incoming gas or too low gas pressure. 2. Gas control knob set to wrong position. 3. Pilot light button not being fully depressed when attempting to light pilot. 4. Pilot orif ice or pilot tube is obstructed or kinked. 5. Pilot electrode not sparking to pilot. 6. Piezo ig ...

  • Bradford-White Corp MI404T*F(BN - page 5

    SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation Inner Door Remo v al Pr ocedur e St ep 1 . R otate knob of the combination thermostat/g as valve to the “OFF” position. St ep 2. R emov e outer jack et burner access door St ep 3. Inner Door Remov al. a) Disconnect resettable thermal switc h wire le ...

  • Bradford-White Corp MI404T*F(BN - page 6

    6 SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation Ins t allation of Inner Door wit h Gask et St ep 7 . Clean an y residual gask et residue or other debris from combustion chamber sur face before installing the inner door/gask et assembly . St ep 8. Place the lef t side inner door into position fir st ...

  • Bradford-White Corp MI404T*F(BN - page 7

    7 SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation St ep 1 0. Firmly place right side inner door flange agains t the lef t side inner door f lange and secure with two 1/4” drive screws from step 3c. DO NOT O VER TIGHTEN SCREWS. St ep 1 1 . Align right side inner door to combustion chamber and verify ...

  • Bradford-White Corp MI404T*F(BN - page 8

    8 SERVICE PROCEDURE RG-II Thermocouple T esting and Replacement Closed Cir cuit Ther mocouple T es ting St ep 1 . Disconnect thermocouple from combination thermostat/g as valve. St ep 2. Connect a thermocouple adapter (BWC P/N 239-44642-00, R ober tshaw P/N 75036) at the thermocouple location in the combination thermostat/g as valve. St ep 3. R eco ...

  • Bradford-White Corp MI404T*F(BN - page 9

    9 SERVICE PROCEDURE RG-II Thermocouple T esting and Replacement Ther mocouple R eplacement St ep 1 . T ur n of f gas supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. Remo ve outer jack et door . St ep 3. R emov e right side of inner door per SERVICE PROCEDURE RG-I, st eps 3a through 3c. St e ...

  • Bradford-White Corp MI404T*F(BN - page 10

    10 SERVICE PROCEDURE RG-III Pilot Assembly Inspection, Cleaning and R eplacement Pilot/Electr ode Assembly Inspection, Cleaning and Replacement St ep 1 . T ur n of f gas supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. Remo ve outer jack et door . St ep 3. R emov e right side of inner door p ...

  • Bradford-White Corp MI404T*F(BN - page 11

    11 SERVICE PROCEDURE RG-IV Piezo Igniter , Electrode T esting and Replacement Piezo Ignit er , Electrode T esting and R eplacement With the pilot not in operation (no pilot f lame) y ou can check the Piezo and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action. St ep 1 . Remo ve outer ja ...

  • Bradford-White Corp MI404T*F(BN - page 12

    Combination Ther mos t at/Gas V al v e T esting and R eplacement The combination thermostat/gas valve is a non repairable device. If trouble shooting has determined a problem with the combination thermostat/g as valve, it must be replaced. If the bur ner and/or pilot do not function, service chec ks for gas pressure, thermocouple output, magnet ass ...

  • Bradford-White Corp MI404T*F(BN - page 13

    THERMOC OUPLE TES TIN G See SERVICE PROCEDURE II MA GNET ASSEMBL Y TES TIN G St ep 1 . Disconnect thermocouple from combination thermostat/g as valve. St ep 2. Connect a thermocouple adapter (BWC P/N 239-44642-00, Robertshaw P/N 75036) at the thermocouple location in the combination thermostat/g as valve. St ep 3. R econnect thermocouple to adapter ...

  • Bradford-White Corp MI404T*F(BN - page 14

    C OMBIN A TION THERMOS T A T/GAS V AL VE REPL A CEMENT St ep 1 . R otate knob of the combination thermostat/g as valve to the “OFF” position. St ep 2. T ur n of f gas supply to water heater . St ep 3. Disconnect gas supply line from combination thermostat/g as valve. St ep 4. T ur n of f water supply and drain water heater completely . St ep 5. ...

  • Bradford-White Corp MI404T*F(BN - page 15

    15 St ep 7 . R emov al of combination thermostat/g as valve. a) Disconnect main bur ner feedline (3/4” wrench), pilot tube (7/1 6" wrench) and thermocouple (3/8" wrench) from combination thermostat/g as valve & remov e from the combustion chamber . b) R emov e Piezo brack et with Piezo igniter (refer to SERVICE PROCEDURE RG-IV) from ...

  • Bradford-White Corp MI404T*F(BN - page 16

    St ep 9. R einstallation of inner door assembly . (cont.) b) Clean any gask et residue or other debris from combustion chamber surface before installing the inner door/gask et assembly . c) P osition thermocouple, pilot tube and Piezo wire against lef t side inner door flange gask et. DO N O T R OUTE THR OUGH R ADIUSED CHANNEL WITH FEEDLINE. Be sur ...

  • Bradford-White Corp MI404T*F(BN - page 17

    MAIN BURNER: Inspection, A djus tment, Cleaning and Replacement At periodic intervals (not more then 6 months) a visual inspection should be made of the main bur ner f or proper opera- tion and to insure no debris accumulating. Main burner should light smoothly from pilot and burn with a blue f lame with a minimum of yellow tips. St eel burner mode ...

  • Bradford-White Corp MI404T*F(BN - page 18

    MAIN BURNER: Inspection, A djus tment, Cleaning and Replacement (cont.) St ep 3. Full y inspect inner gask et per SERVICE PROCEDURE RG-I, st ep 4. Replace gask et if required follo wing SERVICE PROCEDURE I, st eps 5 & 6. St ep 4. Be cer tain that thermocouple, pilot tube and Piezo wire are routed b y inner door f lange as shown and Reinstall in ...

  • Bradford-White Corp MI404T*F(BN - page 19

    BURNER CLEANIN G (cont.) St ep 5. Disconnect (unscrew) main burner (stamped steel “B” bur ner) from main burner orif ice or on cast iron bur ners (“C” burner), loosen air shutter & disconnect (unscrew) feedline from burner . St ep 6. Remo ve main burner orif ice from feed line (1/2” wrench on steel burner , 3/8" wrench on cast ir ...

  • Bradford-White Corp MI404T*F(BN - page 20

    RESETT ABLE THERMAL SWIT C H C ONTINUIT Y TES TIN G St ep 1 . Remo ve outer jack et door . St ep 2. Disconnect wire leads from resettable thermal switc h. St ep 3. Using a multimeter capable of measuring continuity (Ohms), place one probe of meter on one of the brass connection tabs of the resettable thermal switch, and the remaining probe on the o ...

  • Bradford-White Corp MI404T*F(BN - page 21

    RESETT ABLE THERMAL SWIT C H REPL A CEMENT St ep 1 . R otate knob of combination thermostat gas valve to the of f position. St ep 2. Remo ve outer jack et door . St ep 3. Disconnect wire leads from resettable thermal switc h. St ep 4. R emov e resettable thermal switc h from inner door (Phillips screw driver). St ep 5. Place new resettable thermal ...

  • Bradford-White Corp MI404T*F(BN - page 22

    Scr eenLok Flame Ar r es t or Cleaning St ep 1 . R otate knob of combination thermostat gas valve to the of f position. St ep 2. Remo ve outer jack et door . St ep 3. Remo ve inner door per SERVICE PROCEDURE RG-I, st ep 3a through 3e. St ep 4. Disconnect main bur ner feed line (3/4 wrench), pilot tube (7/1 6 wrench) and thermocouple (3/8) wrench fr ...

  • Bradford-White Corp MI404T*F(BN - page 23

    23 Dip T ube Inspection and R eplacement St ep 1 . R otate knob of combination thermostat/gas valve to “OFF” position. St ep 2. T ur n of f c old water supply to heater . Connect hose to drain spigot of wat er heater and rout e to an open drain. Open a nearby hot water faucet to vent heater f or draining. Open drain spigot of water heater and a ...

  • Bradford-White Corp MI404T*F(BN - page 24

    24 Anode Inspection and R eplacement St ep 1 . T ur n of f water supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. T ur n of f c old water supply to heater . Connect hose to drain spigot of wat er heater and rout e to an open drain. Open a nearby hot water faucet to vent heater f or draining. ...

  • Bradford-White Corp MI404T*F(BN - page 25

    25 1 Draf t Hood 2 Hot Water Outlet/Anode 3 Cold Water Inlet T ube 4 Flue Baf f le 5 T&P Relief Valv e 6 Thermostat 7 Piezo Igniter 8 Brass Drain Valv e 9 Screw -#8- 1 8 x 3/4 Hex Washer Head 1 0 Screw -#1 0- 1 2 x 3/4 Hex Washer Head 1 1 Lef t Side Inner Door with Gasket 1 2 Complete Right Side Inner Door 1 2A Right Side Inner Door with Gasket ...

  • Bradford-White Corp MI404T*F(BN - page 26

    26 Notes ...

  • Bradford-White Corp MI404T*F(BN - page 27

    27 Notes ...

  • Bradford-White Corp MI404T*F(BN - page 28

    Sales/ 800-523-2931 Fax/ 215-641-1670 Technical Support/ 800-334-3393 Fax/ 269-795-1089 W arranty/ 800-531-2111 Fax/ 269-795-1089 International: T elephone/ 215-641-9400 T elefax/ 215-641-9750 Ambler , P A 888-538-7833 Fax on Demand: bradfor dwhite.com www. For U.S. and Canada field service, contact your professional installer or local Bradford Whi ...

メーカー Bradford-White Corp カテゴリー Water Heater

Bradford-White Corp MI404T*F(BNのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MI404T*F(BNの取扱説明書
- Bradford-White Corpの製品カード
- パンフレット
- またはBradford-White Corp MI404T*F(BNの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bradford-White Corp MI404T*F(BNの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bradford-White Corp MI404T*F(BNの取り付け説明書、サービスマニュアル、簡易説明書、またはBradford-White Corp MI404T*F(BNのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bradford-White Corp MI404T*F(BNの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Bradford-White Corp MI404T*F(BNデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBradford-White Corp MI404T*F(BNを使用するのを助ける技術的文書のことです。説明書は通常、全てのBradford-White Corp MI404T*F(BNユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bradford-White Corpの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bradford-White Corp MI404T*F(BNの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBradford-White Corp MI404T*F(BNの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bradford-White Corp MI404T*F(BNに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bradford-White Corp MI404T*F(BNデバイスの基本機能を使うにあたってのヒント。 Bradford-White Corp MI404T*F(BNのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bradford-White Corp MI404T*F(BNに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBradford-White Corp MI404T*F(BNのメーカー/サービスへの連絡先に関する情報。

Bradford-White Corp MI404T*F(BNについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBradford-White Corp MI404T*F(BNの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBradford-White Corp MI404T*F(BNで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)