    375 Marcus Boulevard • Hauppauge, NY 1 1 788 • USA 63 1 .273.0500 • Fax: 63 1 .273.077 1 e-mail: info@ultraviolet.com Extensive Product Information A vailable at: Document No. 98 - 1 123E1 • Revised February 2007 • © 1994-2007 Atlantic Ultraviolet Corporation www .ultraviolet.com ...

  • Atlantic Ultraviolet MP13A - page 2

    2 T ABLE OF CONTENTS S AFETY W ARNINGS .....................................................................................................................................................3 SAFETY INSTRUCTIONS ............................................................................................................................................ ...

  • Atlantic Ultraviolet MP13A - page 3

    3 SAFETY W ARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property . This ...

  • Atlantic Ultraviolet MP13A - page 4

    4 PRODUCT APPLICA TION C ONSTRUCTION • The water purifier is designed to mount horizontally . • A drain port on the chamber aids in draining of the purifier . • The water purifier chamber is passivated and electropolished type 316 Stainless S teel. • The ballast housing is a combination of Stainless S teel T ype 304 and Aluminum Alloy . • ...

  • Atlantic Ultraviolet MP13A - page 5

    5 INST ALLA TION L OCA TION 1. The water purifier is intended for indoor use only . The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier , should be between 33  F and 100  F. 2. Electrical power supplied to the water purifier MUST mat ...

  • Atlantic Ultraviolet MP13A - page 6

    6 6 3. The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting holes in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its plumbing connections. 4. The water purifier must be connected to the cold water line only . 5. It is reco ...

  • Atlantic Ultraviolet MP13A - page 7

    7 R ECOMMENDED O PTIONS 1 . Guardian ™ Ultraviolet Monitor: V isually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier . The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultra ...

  • Atlantic Ultraviolet MP13A - page 8

    8 MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “ W ater Quality ” in the “ Pr oduct Application ” section. Ordinary mainte- nance consists of; • Lamp replacement is recommended every 10,000 hours of operation, appro ...

  • Atlantic Ultraviolet MP13A - page 9

    9 S tep 2 - Remove End-Cap S tep 3 - W ithdraw Lamp S tep 4 & 5 - Remove Sockets S tep 6 - Remove Lamp L AMP I NST ALLA TION OR R EPLACEMENT Figure 3 - Lamp Replacement 1. Disconnect power to water purifier . 2. Remove both easy-off end caps by pulling each cap of f static gland nut. Slide each end cap along the wire away from the socket. 3. Ca ...

  • Atlantic Ultraviolet MP13A - page 10

    10 1. Disconnect power to water purifier . 2. Shut off water supply to water purifier via inlet and outlet shut of f valves. Drain chamber by removing drain plug. Once the chamber is completely drained, remove any old sealing tape from the threads of the drain plug, rewrap with 1/2" wide T eflon ® thread sealing tape, reinstall and tighten th ...

  • Atlantic Ultraviolet MP13A - page 11

    11 R EPLACEMENT OF B ROKEN Q UARTZ S LEEVE CAUTION: Broken Quartz is SHARP . It is r ecommended that protective goggles and gloves are worn when handling br oken quartz sleeves. 1. Disconnect power to water purifier . 2. Shut off water supply to the water purifier via the inlet and outlet shut of f valves. Drain the chamber by removing the drain pl ...

  • Atlantic Ultraviolet MP13A - page 12

    12 O PTIONAL G UARDIAN ™ ™ U L TRA VIOLET M ONIT OR S ENSOR P ROBE C LEANING Figure 5 - Ultraviolet Monitor and Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity , as shown on the intensity meter , it may be necessary to clean the Ultraviolet Monitor's sensor probe. The senso ...

  • Atlantic Ultraviolet MP13A - page 13

    13 Problem Possible Cause Corrective Action No electrical power… V erify that the purifier is connected to a live power source. Ballast Disconnect the purifier from utility power . Replace lamp. Lamp-out Protection The purifier must remain disconnected from power for (MP16A, MP22A & MP36C) two (2) minutes to reset. Cracked or broken Shut down ...

  • Atlantic Ultraviolet MP13A - page 14

    14 TECHNICAL SPECIFICA TIONS T able 4 - T echnical Specifications Model: MP13A MP16A MP22A MP36C MP49C Flow Rate (GPM): 2 3 6 12 20 InletOutlet Size: 1 / 2 " m NPT 3 / 4 " m NPT 3 / 4 " m NPT 1 " m NPT 1- 1 / 2 " m NPT Number of Lamps: 1 1 1 1 1 Lamp Model No.: GPH212T5L GPH287T5L GPH436T5L G36T6L G48T6L Length: 13- 1 / 2 ...

  • Atlantic Ultraviolet MP13A - page 15

    15 OPTIONAL ACCESSORIES Optional accessories are available for operation at 120v 60Hz or 220v 50Hz, unless specified. Please specify . Consult Factory for 12v DC or other special input power requirements. T able 5 - Optional Accessories Optional Accessories Available for: Guardian ™ Ultraviolet Monitor - Analog / Digital MP13A through MP49C Sentr ...

  • Atlantic Ultraviolet MP13A - page 16

    16 REPLACEMENT P AR TS Mighty   Pure ™ ™ Models MP13A, MP16A & MP22A Figure 6 - Exploded V iew MP13A, MP16A & MP22A ...

  • Atlantic Ultraviolet MP13A - page 17

    17 ITEM MP13A MP16A MP22A NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1 108B 2 00-1108B 2 00-1108B 3 Lamp Spacer 2 25-0208A 2 25-0208A 2 25-0208A 4 Lead W ire & Socket 2 05-1219B2 2 05-1219B2 2 05-1219B3 5 Lamp 1 05-1400 1 05-1098 1 05-109 ...

  • Atlantic Ultraviolet MP13A - page 18

    18 REPLACEMENT P AR TS Mighty   Pure ™ ™ Models MP36C & MP49C Figure 7 - Exploded V iew MP36C & MP49C ...

  • Atlantic Ultraviolet MP13A - page 19

    19 ITEM MP36C MP49C NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1108B 2 00-1 108B 3 Lamp Spacer - - 2 25-0209A 4 Lead W ire & Socket 2 05-1218A2 2 05-1218A2 5 Lamp 1 05-1343 1 05-1334 6 Static Gland Nut 2 25-1492D 2 25-1492D 7 T eflon ® W asher 2 25-1235A 2 25-1235 ...

  • Atlantic Ultraviolet MP13A - page 20

    20 W ARRANTY W e warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product’ s total rated life, whichever first occurs. W ithin the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and wh ...

Fabricant Atlantic Ultraviolet Catégorie Water System

Les documents que nous recevons du fabricant de l'appareilAtlantic Ultraviolet MP13A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Atlantic Ultraviolet
- manuels d’utilisations MP13A
- fiches produit Atlantic Ultraviolet
- dépliants
- ou étiquettes-énergie Atlantic Ultraviolet MP13A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Atlantic Ultraviolet MP13A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Atlantic Ultraviolet MP13A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Atlantic Ultraviolet MP13A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Atlantic Ultraviolet MP13A.

Manuel d’utilisation complet de l’appareil Atlantic Ultraviolet MP13A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Atlantic Ultraviolet MP13A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Atlantic Ultraviolet MP13A.

Le manuel d’utilisation complet Atlantic Ultraviolet, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Atlantic Ultraviolet MP13A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Atlantic Ultraviolet MP13A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAtlantic Ultraviolet MP13A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Atlantic Ultraviolet MP13A - qui devraient nous aider dans les premières étapes lors de l'utilisation Atlantic Ultraviolet MP13A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Atlantic Ultraviolet MP13A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Atlantic Ultraviolet MP13A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Atlantic Ultraviolet MP13A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Atlantic Ultraviolet MP13A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Atlantic Ultraviolet MP13A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)