    375 Marcus Boulevard • Hauppauge, NY 1 1 788 • USA 63 1 .273.0500 • Fax: 63 1 .273.077 1 e-mail: info@ultraviolet.com Extensive Product Information A vailable at: Document No. 98 - 1 123E1 • Revised February 2007 • © 1994-2007 Atlantic Ultraviolet Corporation www .ultraviolet.com ...

  • Atlantic Ultraviolet MP13A - page 2

    2 T ABLE OF CONTENTS S AFETY W ARNINGS .....................................................................................................................................................3 SAFETY INSTRUCTIONS ............................................................................................................................................ ...

  • Atlantic Ultraviolet MP13A - page 3

    3 SAFETY W ARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property . This ...

  • Atlantic Ultraviolet MP13A - page 4

    4 PRODUCT APPLICA TION C ONSTRUCTION • The water purifier is designed to mount horizontally . • A drain port on the chamber aids in draining of the purifier . • The water purifier chamber is passivated and electropolished type 316 Stainless S teel. • The ballast housing is a combination of Stainless S teel T ype 304 and Aluminum Alloy . • ...

  • Atlantic Ultraviolet MP13A - page 5

    5 INST ALLA TION L OCA TION 1. The water purifier is intended for indoor use only . The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier , should be between 33  F and 100  F. 2. Electrical power supplied to the water purifier MUST mat ...

  • Atlantic Ultraviolet MP13A - page 6

    6 6 3. The water purifier should be mounted horizontally on a flat dry surface. Secure the water purifier using the mounting holes in the ballast housing or with the optional wall mounting kit. The purifier should not be solely supported by its plumbing connections. 4. The water purifier must be connected to the cold water line only . 5. It is reco ...

  • Atlantic Ultraviolet MP13A - page 7

    7 R ECOMMENDED O PTIONS 1 . Guardian ™ Ultraviolet Monitor: V isually indicates the level of germicidal ultraviolet energy that penetrates the quartz sleeve and the water within the water purifier . The ultraviolet monitor is capable of operating an optional audio alarm and/or solenoid valve. The ultraviolet monitor will detect reduction of ultra ...

  • Atlantic Ultraviolet MP13A - page 8

    8 MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “ W ater Quality ” in the “ Pr oduct Application ” section. Ordinary mainte- nance consists of; • Lamp replacement is recommended every 10,000 hours of operation, appro ...

  • Atlantic Ultraviolet MP13A - page 9

    9 S tep 2 - Remove End-Cap S tep 3 - W ithdraw Lamp S tep 4 & 5 - Remove Sockets S tep 6 - Remove Lamp L AMP I NST ALLA TION OR R EPLACEMENT Figure 3 - Lamp Replacement 1. Disconnect power to water purifier . 2. Remove both easy-off end caps by pulling each cap of f static gland nut. Slide each end cap along the wire away from the socket. 3. Ca ...

  • Atlantic Ultraviolet MP13A - page 10

    10 1. Disconnect power to water purifier . 2. Shut off water supply to water purifier via inlet and outlet shut of f valves. Drain chamber by removing drain plug. Once the chamber is completely drained, remove any old sealing tape from the threads of the drain plug, rewrap with 1/2" wide T eflon ® thread sealing tape, reinstall and tighten th ...

  • Atlantic Ultraviolet MP13A - page 11

    11 R EPLACEMENT OF B ROKEN Q UARTZ S LEEVE CAUTION: Broken Quartz is SHARP . It is r ecommended that protective goggles and gloves are worn when handling br oken quartz sleeves. 1. Disconnect power to water purifier . 2. Shut off water supply to the water purifier via the inlet and outlet shut of f valves. Drain the chamber by removing the drain pl ...

  • Atlantic Ultraviolet MP13A - page 12

    12 O PTIONAL G UARDIAN ™ ™ U L TRA VIOLET M ONIT OR S ENSOR P ROBE C LEANING Figure 5 - Ultraviolet Monitor and Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity , as shown on the intensity meter , it may be necessary to clean the Ultraviolet Monitor's sensor probe. The senso ...

  • Atlantic Ultraviolet MP13A - page 13

    13 Problem Possible Cause Corrective Action No electrical power… V erify that the purifier is connected to a live power source. Ballast Disconnect the purifier from utility power . Replace lamp. Lamp-out Protection The purifier must remain disconnected from power for (MP16A, MP22A & MP36C) two (2) minutes to reset. Cracked or broken Shut down ...

  • Atlantic Ultraviolet MP13A - page 14

    14 TECHNICAL SPECIFICA TIONS T able 4 - T echnical Specifications Model: MP13A MP16A MP22A MP36C MP49C Flow Rate (GPM): 2 3 6 12 20 InletOutlet Size: 1 / 2 " m NPT 3 / 4 " m NPT 3 / 4 " m NPT 1 " m NPT 1- 1 / 2 " m NPT Number of Lamps: 1 1 1 1 1 Lamp Model No.: GPH212T5L GPH287T5L GPH436T5L G36T6L G48T6L Length: 13- 1 / 2 ...

  • Atlantic Ultraviolet MP13A - page 15

    15 OPTIONAL ACCESSORIES Optional accessories are available for operation at 120v 60Hz or 220v 50Hz, unless specified. Please specify . Consult Factory for 12v DC or other special input power requirements. T able 5 - Optional Accessories Optional Accessories Available for: Guardian ™ Ultraviolet Monitor - Analog / Digital MP13A through MP49C Sentr ...

  • Atlantic Ultraviolet MP13A - page 16

    16 REPLACEMENT P AR TS Mighty   Pure ™ ™ Models MP13A, MP16A & MP22A Figure 6 - Exploded V iew MP13A, MP16A & MP22A ...

  • Atlantic Ultraviolet MP13A - page 17

    17 ITEM MP13A MP16A MP22A NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1 108B 2 00-1108B 2 00-1108B 3 Lamp Spacer 2 25-0208A 2 25-0208A 2 25-0208A 4 Lead W ire & Socket 2 05-1219B2 2 05-1219B2 2 05-1219B3 5 Lamp 1 05-1400 1 05-1098 1 05-109 ...

  • Atlantic Ultraviolet MP13A - page 18

    18 REPLACEMENT P AR TS Mighty   Pure ™ ™ Models MP36C & MP49C Figure 7 - Exploded V iew MP36C & MP49C ...

  • Atlantic Ultraviolet MP13A - page 19

    19 ITEM MP36C MP49C NO. DESCRIPTION QTY P AR T NO. QTY P AR T NO. 1 Easy-Off End Cap 2 25-1499A1 2 25-1499A1 2 Rubber O-ring, Static Gland 2 00-1108B 2 00-1 108B 3 Lamp Spacer - - 2 25-0209A 4 Lead W ire & Socket 2 05-1218A2 2 05-1218A2 5 Lamp 1 05-1343 1 05-1334 6 Static Gland Nut 2 25-1492D 2 25-1492D 7 T eflon ® W asher 2 25-1235A 2 25-1235 ...

  • Atlantic Ultraviolet MP13A - page 20

    20 W ARRANTY W e warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product’ s total rated life, whichever first occurs. W ithin the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and wh ...

メーカー Atlantic Ultraviolet カテゴリー Water System

Atlantic Ultraviolet MP13Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MP13Aの取扱説明書
- Atlantic Ultravioletの製品カード
- パンフレット
- またはAtlantic Ultraviolet MP13Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Atlantic Ultraviolet MP13Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Atlantic Ultraviolet MP13Aの取り付け説明書、サービスマニュアル、簡易説明書、またはAtlantic Ultraviolet MP13Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Atlantic Ultraviolet MP13Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Atlantic Ultraviolet MP13Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAtlantic Ultraviolet MP13Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのAtlantic Ultraviolet MP13Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Atlantic Ultravioletの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Atlantic Ultraviolet MP13Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAtlantic Ultraviolet MP13Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Atlantic Ultraviolet MP13Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Atlantic Ultraviolet MP13Aデバイスの基本機能を使うにあたってのヒント。 Atlantic Ultraviolet MP13Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Atlantic Ultraviolet MP13Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAtlantic Ultraviolet MP13Aのメーカー/サービスへの連絡先に関する情報。

Atlantic Ultraviolet MP13Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAtlantic Ultraviolet MP13Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAtlantic Ultraviolet MP13Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)