    R INS TALLATION INS TALLATION INST RUCTIONS INST RUCTIONS GEM-RP3DGT L Digital Ke ypad W I982A 6/99 © Napco 1999 Quick Start: 1. Referring to the control panel wiring diagram, connect siren, aux. power, pgm. output, remote bus, earth ground, zone and telephone wiring. NOTE: See Installation Instructions for the appropriate control panel. 2. Connec ...

  • Napco Security Technologies GEM-P816 - page 2

    2 ...

  • Napco Security Technologies GEM-P816 - page 3

    INTRODUCTION The GEM-RP3DGTL is a dual 7-segment digital keypad that is compat ible with the NAPCO GEM-Series GEM-P816, P1632, P3200 & P9600 control-panels. Refer to User Guide OI249 for operation instructions. While the GEM-RP3DGTL may be used to fully program the control, the GEM-RP1CAe2 keypad provides the optimum in ease of keypad programmi ...

  • Napco Security Technologies GEM-P816 - page 4

    EASY PROGRAM MODE OVERVIEW ENTERING THE EASY KEYPAD PROGRAM MODE 1 Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if programmed and press A 2 Press NO ( F ) repeatedly until function “ 17 “ (Activate Program Mode) is displayed. NOTE: If you pass “ 17 “ you can scroll back by pressi ...

  • Napco Security Technologies GEM-P816 - page 5

    Total Number of Zones in Area 1 (Appears for New Panel Only) Press the A button and then directly enter the total number of zones to be programmed for Area 1. Valid entries are from 01 to 32. Directly enter the total number of zones, including leading zeros. Use number buttons 1 through 9 . NOTE: Press the 0 button for a zero. The system is based o ...

  • Napco Security Technologies GEM-P816 - page 6

    Entry/Exit Zones in Area 1 (Appears for New Panel Only) Press the A button and then directly enter the zone number of any zones which are to be used as Entry/Exit zones. Valid entries are from 01 to 32. Di- rectly enter each zone number, including leading zeros. Use number buttons 0 through 9 . Press J to save and then repeat for any additional zon ...

  • Napco Security Technologies GEM-P816 - page 7

    7 Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9 . NOTE: Press G0 for a zero and 0 for a blank space (•). Press G 1 through G 4 for letters B–E, respectively. Press J to save. Press NEXT ( E ) button to proceed. NOTE: Central Station Receiver 2 and 3 Forma ...

  • Napco Security Technologies GEM-P816 - page 8

    RF Transmitter Programming (For wireless systems only. Also see Quick Method, which follows) Press the A button and for each transmitter (key fob transmitters also), then directly enter: 1 The zone number (01–32) to which the transmitter will be mapped, including leading zeros. 2 The 6-digit RF ID # printed on the transmitter and box. 3 The 1-dig ...

  • Napco Security Technologies GEM-P816 - page 9

    9 Key Fob Transmitters Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF buttons (refer to control panel installation instructions). Press the A button and for each Key Fob Transmitter, enter: 1 The Key Fob Transmitter number (01–15). 2 The area number to which transmitter is assigned (1 or 2); enter 0 to disable keyfob. ...

  • Napco Security Technologies GEM-P816 - page 10

    Total Number of Zones and Keypads in Area 1. Total Number of Zones and Keypads in Area 2. (Appears for New Panel Only) 1 Press the A button and then press 3 to select the total number of zones to be programmed for Area 1. Valid entries are from 08 to 24 in multiples of 4. 2 Press 2 and press 3 to select the total number of keypads to be programmed ...

  • Napco Security Technologies GEM-P816 - page 11

    11 Central Station Receiver 1 Format From the table below, enter the central station's receiver format. Use number buttons 1 through 9 . NOTE: Press G0 for a zero and 0 for a blank space (•). Press G 1 through G 4 for letters B–E, respectively. Press J to save. Press NEXT ( E ) button to proceed. NOTE: Central Station Receiver 2 and 3 Form ...

  • Napco Security Technologies GEM-P816 - page 12

    12 RF Transmitter Programming (For wireless systems only. Also see Quick Method, which follows) Press the A button and for each transmitter and directly enter: 1 The zone number (01–96) to which the transmitter will be mapped, including leading zeros. 2 The 6-digit RF ID # printed on the transmitter and box. 3 The 1-digit checksum number (C) prin ...

  • Napco Security Technologies GEM-P816 - page 13

    Key Fob Transmitters Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF buttons (refer to control panel installation instructions). Press the A button and for each Key Fob Transmitter, enter: 1 The Key Fob Transmitter number (01–15). 2 The area number to which transmitter is assigned (1-8); enter 0 to disable keyfob. 3 The ...

  • Napco Security Technologies GEM-P816 - page 14

    DIRECT ADDRESS PROGRAM MOD E This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad Programming Worksheets contained in the control panel programming guide. Refer to these worksheets to identify the 4-digit location (address) of the feature to be programmed. An illustrative example is prov ...

  • Napco Security Technologies GEM-P816 - page 15

    15 ...

  • Napco Security Technologies GEM-P816 - page 16

    NAPCO SECURITY SYSTEMS, INC. (NAPCO) war- rants its products to be free from manufacturing defects in materials and workmanship for thirty-six months fol- lowing the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original pur- chaser or user. This ...

Fabricant Napco Security Technologies Catégorie Door

Les documents que nous recevons du fabricant de l'appareilNapco Security Technologies GEM-P816 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Napco Security Technologies
- manuels d’utilisations GEM-P816
- fiches produit Napco Security Technologies
- dépliants
- ou étiquettes-énergie Napco Security Technologies GEM-P816
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Napco Security Technologies GEM-P816.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Napco Security Technologies GEM-P816, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Napco Security Technologies GEM-P816. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Napco Security Technologies GEM-P816.

Manuel d’utilisation complet de l’appareil Napco Security Technologies GEM-P816, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Napco Security Technologies GEM-P816 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Napco Security Technologies GEM-P816.

Le manuel d’utilisation complet Napco Security Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Napco Security Technologies GEM-P816 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Napco Security Technologies GEM-P816, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNapco Security Technologies GEM-P816 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Napco Security Technologies GEM-P816 - qui devraient nous aider dans les premières étapes lors de l'utilisation Napco Security Technologies GEM-P816
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Napco Security Technologies GEM-P816
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Napco Security Technologies GEM-P816 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Napco Security Technologies GEM-P816?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Napco Security Technologies GEM-P816, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Napco Security Technologies GEM-P816 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)