Manuel d’utilisation APC AP9830

31 pages 0.61 mb
Télécharger

Aller à la page of 31

Summary
  • APC AP9830 - page 1

    Remote Power -Off Devic e AP9830 Ins talla tion an d Quick Star t ...

  • APC AP9830 - page 2

    Remote Po wer-Off Devic e — Installa tion and Q uick Start Conte nts Features and Requirements 1 Feature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Hardwa re Re quire ments . . . . . . . . . . . . . . . . . . . . 2 Safety Inf ormation 3 Avoid H azardo us Confi guration s . . . . . . . . . . . . . . 3 Exam ple of th e pote ...

  • APC AP9830 - page 3

    ii Remote Po wer-Off Devic e — Installation a nd Quick Start Contents Set up t he Rem ote P ower-Of f Devic e . . . . . . . . . . 14 Remot e switch: r equirement s and pin as signment 16 Pin locati ons for the keystone j ack 16 Pin locati ons for the RJ -11 conne ctor 16 Connect the swit ch cable to the keystone ja ck 17 Placemen t of accessor ie ...

  • APC AP9830 - page 4

    1 Featur es and Re quir ements Featur es The APC ® Remote Pow er-Off Device (RPO), AP9830, enables you to tu rn off the output pow er of an APC uninterruptible pow er supply (UPS) imm ediately by a remote swit ch. For exam ple: • If the UPS itself is n ot readily accessible, place the RPO in a convenien t location. • T o turn off the output po ...

  • APC AP9830 - page 5

    2 Remote Po wer-Of f Devic e — Installation a nd Quick St art H a rdw a re R e q u i rem e n t s The Remote Power- Off Device requires the f ollowi ng: • A Sm art-UPS ® or Matrix-UPS ™ . • A sw itch (SEL V or Class 2 circuit). • A cable to connect the rem ote sw itch to the R emote Power-Off Device. Note A Symme t ra ™ UPS has a built- ...

  • APC AP9830 - page 6

    3 Safety Information Avoid Hazar dous Configurations Example of the potentia l hazard 1. An adm inis trator uses th e remote sw i tch conn ected to the Remote Pow er-Off Device to turn off the output pow er from a UPS, but the UPS continu es to receive utilit y pow e r . 2. From an int erface of an A PC accessory device, a us er issues a com man d ...

  • APC AP9830 - page 7

    4 Remote Po wer-Of f Devic e — Installation a nd Quick St art Eliminate t he Hazard Use a n Emergency Power Off system Matrix-UPS m odels and man y S mart- UPS models have an integrated EPO system th at allow s connected equipmen t to be deenergized immediately f rom a rem ote location with out the UPS switch ing to battery operation. War n in g ...

  • APC AP9830 - page 8

    Remote Power-Off Device — Installation a nd Quick St art 5 Safe ty Inf orma tio n: E limi nat e t he H azar d Block a ccess to acces sory devic es The Remote Power-Off Device can provide a usef ul alternativ e to the integrated EPO interface of a UPS in any of th e followin g situ ations: • Y our system configu ration requires either of th e fo ...

  • APC AP9830 - page 9

    6 Remote Po wer-Of f Devic e — Installation a nd Quick St art Contact Closur e Setup with Multiple UPSs T o elimin ate t he ne ed fo r multip le conta ct cl osu res a t the remo te s w itch , do one of th e foll owing: • Use an applied voltage sw itch. • Use a cascading setup. War n in g T o connect multipl e UPSs to a system that uses contac ...

  • APC AP9830 - page 10

    7 V erify C ontents of the Shipment Unpack and Inspec t the RPO Pa ckage Please r ecycle Receiving inspecti on Inspect the package and conten ts for shipping damag e, and make su re that all parts w ere sent. Report any damage imm ediately to the sh ipping agent, and report mis sing contents, damage, or other problems im m ediately to APC or your A ...

  • APC AP9830 - page 11

    8 Remote Po wer-Of f Devic e — Installation a nd Quick St art Verify Contents o f the Ship ment: Unpack and Inspect the RPO P ackage • Remote Pow er-Off Device • Keystone jack (750-0023) • A strip of hook-an d-loop fastener (not sh own here) for optional mount ing of th e Rem ote Power-Off Dev ice. ...

  • APC AP9830 - page 12

    9 Components of the RPO Side Views View fr om the server sid e of the RPO View fr om the UPS side of th e RPO  DB9 female port to connect to server or accessories  RJ-1 1 port: RPO/Cascade In  RJ-1 1 port: Cascade Out     Configu ration DIP sw itches  DB9 Male Port to connect to UPS For DIP switch set tings , see “ Conf ig ...

  • APC AP9830 - page 13

    10 Remote Power- Off Device — Insta llation and Q uick Start To p V i e w  Pow e r-O ff /T e st L ED  Labels that identif y component s on the sides of the RPO    ...

  • APC AP9830 - page 14

    11 Configur ation and Setup Overvi ew T o configure and set up th e Rem ote Power-Off Dev ice: 1. C onfig ure the RPO to oper ate in T est ( Disab led ) po w er - off mode by settin g DIP sw itch #3 to the up position. 2. Connect the RPO. 3. T est the RPO w hile leavin g DIP sw itch #3 in the u p position. 4. Configu re the RPO to operate in the En ...

  • APC AP9830 - page 15

    12 Remote Power- Off Device — Insta llation and Q uick Start Config ur e the R emote Power -Off Device Ty p e s o f r e m o t e switches supported The RPO supports two ty pes of remote sw it ches: • A contact closure sw itch toggles betw een an open and closed circuit. • A voltage in put sw itch applies an d removes a voltag e signal. Set the ...

  • APC AP9830 - page 16

    Remote Power-Off Device — Installation a nd Quick St art 13 Configura tion and Setup: Confi gure the Remote Po wer -Off Device Power -off m ode: DIP switch #3. In either power-off mode, the Rem ote Power-Off Dev ice LED illum in ates wh en the device is connected and config ured properly and the rem ote swit ch is being asserted. DIP Switch #4. D ...

  • APC AP9830 - page 17

    14 Remote Power- Off Device — Insta llation and Q uick Start Set up t he Remote Power-Off De vice Connect s ingle and multi ple RPOs Y ou can connect one R em ote Power-O ff Device to one rem ote swit ch to control one UPS, or you can connect m u ltiple Remote Pow er-Off Devices to one rem ote sw itch to control mult iple UPSs sim ultaneous ly . ...

  • APC AP9830 - page 18

    Remote Power-Off Device — Installation a nd Quick St art 15 Configura tion an d Setup: Set u p the Remote Po wer -Off Device Note In the follow ing set-u p diagram, note th at the RJ-1 1 cable connects to the m iddle port, labeled RPO / Cascade In .  APC U PS  Keystone jack  W iring to remote sw itch  Server  Cable provided with UP ...

  • APC AP9830 - page 19

    16 Remote Power- Off Device — Insta llation and Q uick Start Configu ration a nd Setup: Set up the Remote P ower-Off Device Remote s witch: re qu i re m e n ts and pin assign ment Pin locations for the keystone jack Pin locations for the RJ -11 connect or T ype Requirements RPO/Cascade In Pin Assignment Contact Closure • Saf ety Ex tra Low V ol ...

  • APC AP9830 - page 20

    Remote Power-Off Device — Installation a nd Quick St art 17 Configura tion an d Setup: Set u p the Remote Po wer -Off Device Connect th e switch cab le to the keystone jack 1. Strip the cable j acket (the outer ins ulation of th e cable) to expose 1 inch (25.4 mm ) of the insu lated w ires (unstripped 26 – 22 A WG required). 2. Cut one of the t ...

  • APC AP9830 - page 21

    18 Remote Power- Off Device — Insta llation and Q uick Start Configu ration a nd Setup: Set up the Remote P ower-Off Device 5. Press each w ire in to its s lot on the clear plastic cap. Then inspect the cap to ensure that each w ire is in the correct slot and that the end of each w i re touches the back of th e slot. 6. Press the plastic cap, wit ...

  • APC AP9830 - page 22

    Remote Power-Off Device — Installation a nd Quick St art 19 Configura tion an d Setup: Set u p the Remote Po wer -Off Device 7. Using slip- joint pliers, terminat e the w ires by pressing the plastic cap and keys tone jack together un til the cap snaps into place. 8. Inspect the jack to ensu re that th e cap is securely snapped into place and tha ...

  • APC AP9830 - page 23

    20 Remote Power- Off Device — Insta llation and Q uick Start How to T urn Off the Output of Multiple UPSs T o set up more than one APC UPS to turn off from on e remote swit ch, y ou mu st have one Remote Pow er-Off Device for each UPS. Y ou can s et up rem ote turnoff of m ultiple UPS output s in either a cascading (serial) config uration or (for ...

  • APC AP9830 - page 24

    Remote Power-Off Device — Installation a nd Quick St art 21 Configura tion and Setup: How to Turn Off th e Output of Mult iple UPSs Matrix-UPS ® in a cascad ing configuration Y ou can in clude only one APC Matrix-U PS in a cascading configuration , and you m u st place it at the end of the series of UPSs (UPS n in the exam ple setup). Connect mu ...

  • APC AP9830 - page 25

    22 Pr oduct Information Selecting and Or dering Components Remote switch specifi catio ns Cabl e re qu i re m e n ts Y ou can u se the tw o RJ-11 cables that cam e w ith the Rem ote Power-Off Device or use ex isting building cables. The cable that connects th e Rem ote Power-Off Device to the rem ote swit ch m ust m eet these requirem ents: • It ...

  • APC AP9830 - page 26

    Remote Power-Off Device — Installation a nd Quick St art 23 Pr oduct Spe cificatio ns Physical Dimensions (H × W × D) Unit Shippi ng 2.54 × 9. 53 × 6.0 5 cm (1.0 0 × 3.75× 2.3 8 in) 7.26 × 24 .13 × 16 .51 cm (2.86 × 9.5 0 × 6.50 in) W eight Unit Shippi ng 0.23 kg (0.5 0 lb) 0.36 kg (0.8 0 lb) Distance (cable length) between th e remote ...

  • APC AP9830 - page 27

    24 Remote Power- Off Device — Insta llation and Q uick Start W arranty and Se rvice Limited warranty APC w arrants the Rem ote Pow er-Off Device to be free from defects in m aterials and w orkm ansh ip for a period of tw o y ears from the date of purchas e. Its obligation under thi s w arranty is limited to repairing or replacing, at its ow n s o ...

  • APC AP9830 - page 28

    Remote Power-Off Device — Installation a nd Quick St art 25 Product In formation: Wa r rant y and Service warranty expired, y ou w ill be charged for repair o r replacement. 4. Pack the unit carefu lly . The warrant y does not cover damage su stained in tran sit. Enclose a letter w ith y our name, address, RMA num ber and dayt ime phone num ber; ...

  • APC AP9830 - page 29

    26 Remote Power- Off Device — Insta llation and Q uick Start Life-Support Policy General poli cy Am erican Power Con version ( APC ) does not recomm end the use of any of its products in th e follow ing s ituations: • In life-su pport applications wh ere failure or malf unction of t h e APC product can be reasonably expected to cause failure of ...

  • APC AP9830 - page 30

    Radio Fr equency Interfer ence This product contains no clocks or oscillators and therefore does not cause interference. ...

  • APC AP9830 - page 31

    *990-0197A* APC W orldwide Customer Support Cust omer supp ort for this or an y other APC produ ct is av ailable at no char ge in a ny of the following ways: • V i sit the APC W eb site to access documen ts in the APC Knowledge Bas e and to subm it custom er supp ort requ ests. – www .apc.com (Corporate Headqu arters) Connect to localized APC W ...

Fabricant APC Catégorie Remote Starter

Les documents que nous recevons du fabricant de l'appareilAPC AP9830 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques APC
- manuels d’utilisations AP9830
- fiches produit APC
- dépliants
- ou étiquettes-énergie APC AP9830
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation APC AP9830.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation APC AP9830, manuels d’entretien, brefs manuels ou manuels de l’utilisateur APC AP9830. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit APC AP9830.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil APC AP9830, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser APC AP9830 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs APC AP9830.

Le manuel d’utilisation complet APC, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel APC AP9830 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières APC AP9830, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAPC AP9830 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil APC AP9830 - qui devraient nous aider dans les premières étapes lors de l'utilisation APC AP9830
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de APC AP9830
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service APC AP9830 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de APC AP9830?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec APC AP9830, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec APC AP9830 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)