Manuel d’utilisation TFA 35.1075

27 pages Non applicable
Télécharger

Aller à la page of 27

Summary
  • TFA 35.1075 - page 1

    31 Nexus W eather Station ( Kat. Nr . 35.1075 ) Instruction Manual TE922 & TS34C IM2(ENG) TFA 11/5/08, 4:01 PM 31 ...

  • TFA 35.1075 - page 2

    32 Introduction Congratulations on your purchase of the “Nexus” W eather Station. The weather station consists of a main console unit, as well as an assortment of remote sensors which collect and transmit a wide range of weather data, including outdoor temperature, humidity , wind speed and direction, rain amount and rain rate. Main Console Uni ...

  • TFA 35.1075 - page 3

    33 Alarms - Single alarm : activated once at specified time - W eekday alarm : activated everyday from Monday to Friday at specified time - Pre-alarm : activated ahead of single or weekday alarm if channel 1 temperature falling to +2 ° C or below . (Fixed 30 minutes) - Programmable snooze function (1-15 minutes) Sunrise time and sunset time - Calc ...

  • TFA 35.1075 - page 4

    34 Contents of Complete W eather Station Kit Before installing your weather station, please check that the following are complete: Fittings Hardware Components AC/DC 7.5V output adaptor USB Main Console Unit Thermo-Hygro Sensor 4 screws for securing unit to ground Rain Sensor: - Funnel shaped Lid with Battery Hatch - Sensor Base - Bucket See - saw ...

  • TFA 35.1075 - page 5

    35 Installing your weather station Setting up the Remote W eather Sensors Before starting up the main console unit, setup all the remote sensors first. When placing the sensors, make sure that they are within receiving range of the console unit. Ideally they should be within the line of sight of the console unit. T ransmission range may be affected ...

  • TFA 35.1075 - page 6

    36 wind-blown rain, or create extra precipitation runoff. Trees and rooftops may also be sources of pollen and debris. - T o avoid rain shadow effects, place the sensor at a horizontal distance corresponding to two to four times the height of any nearby obstruction. - It is important that rain excess can flow freely away from the sensor . Make sure ...

  • TFA 35.1075 - page 7

    37 - Switches to next mode in anti-clockwise direction - Increment for setting parameters - Switches to next mode in clockwise direction - Decrement for setting parameters SET - Rotates display for current mode - Press and hold to enter setup or change units - Confirmation for setting parameters MEMOR Y - Shows records for moon phase, temperature, ...

  • TFA 35.1075 - page 8

    38 The following controls are only available on the main console unit: LIGHT SENSOR - AUTO, ON, OFF - T oggles the light sensor function to automatic, on or off SENSITIVITY - HIGH/LOW - Adjusts the sensitivity of the light sensor Navigating between Different Modes There are 7 modes available on the main console unit, and each one displays a differe ...

  • TFA 35.1075 - page 9

    39 T emperature and Humidity Mode - T emperature and humidity trend and readings for indoor and selected channel - Comfort level - Dew point - T emperature alerts Rain Mode - Precipitation amount for last hour , last 24 hour, yesterday , last week and last month - Rainfall alert Wind Mode - W ind Chill - T emperature at place of anemometer - W ind ...

  • TFA 35.1075 - page 10

    40 LED Backlight Options The backlight of the main console unit can be turned permanently on/off or automatically toggled when environment lighting level is low . Use the light sensor switch at the back of the unit to select lighting preferences. For the automatic backlight function, the sensitivity of the light sensor can be adjusted to high or lo ...

  • TFA 35.1075 - page 11

    41 V iewing Pressur e and Altitude Data In Pressure and W eather Forecast Mode, each press of SET rotates display between: - Sea level pressure - Local pressure - Local altitude Setting the Sea Level Pressur e 1. In Pressure and W eather Forecast Mode, press SET until the sea level pressure is displayed. 2. Press and hold SET . The Sea Level Pressu ...

  • TFA 35.1075 - page 12

    42 Understanding the W eather For ecast Display W eather For ecast Status Display and Sunny Partly Cloudy and Cloudy Light Rain and and Heavy Rain and Unstable W eather and Light Snow Heavy Snow and and and NOTE: 1. The accuracy of a general pr essur e-based weather forecast is about 70%. 2. The weather for ecasts. It may not necessarily r eflect t ...

  • TFA 35.1075 - page 13

    43 Understanding the Moon Phase Diagram Clock and Alarm Mode The main console unit can be configured to display the time, calendar or UTC time. There are three time alarms available on the console unit: Single alarm : activated once at specified time W eekday alarm : activated everyday from Monday to Friday at specified time Pre-alarm : activated a ...

  • TFA 35.1075 - page 14

    44 Rotating between Different Clock/Calendar Displays In Clock and Alarm Mode, each press of SET rotates clock display between: - Hour: Minute for UTC (Coordinated Universal T ime) - Hour: Minute: W eekday - Hour: Minute: City - Hour: Minute: Second - Month: Day: Y ear (or Day: Month Y ear depending on settings) Activating/Deactivating the T ime Al ...

  • TFA 35.1075 - page 15

    45 Icon RC Reception Strength (Flashing) Undefined data Reception failed for 24 hours W eak signal, but can be decoded Strong signal T o turn this function on/off: Press and hold the button [ ] . If RC reception is activated, a tower icon will start flashing beside the clock icon. If RC reception is deactivated, the triangular tower icon will disap ...

  • TFA 35.1075 - page 16

    46 4. Repeat above procedure to set minute of latitude, degree of longitude, minute of longitude, time zone of the city , and DST selection. 5. Upon completion the display will be returned to Sunrise/Sunset Mode. Note: Press and hold SET anytime during the setup to return to normal Clock and Alarm Mode. All settings made will be discarded. V iewing ...

  • TFA 35.1075 - page 17

    47 Accessing T emperature and Humidity Mode From the main console unit: Press the button [ ] or [ ] until the OUT Icon and IN icon on the upper right of the display starts flashing. V iewing T emperature and Humidity Display for each Channel For Static Display: In T emperature and Humidity Mode, each press of CHANNEL rotates display between differe ...

  • TFA 35.1075 - page 18

    48 Remote Sensor Status The wave icon above the current channel display shows the connection status of the corresponding remote sensor: Activating Main Console Unit to Search for All Remote Sensor Signals The main console unit may be manually activated to search for signals from all remote sensors. Press and hold the button [ ] to enforce a search. ...

  • TFA 35.1075 - page 19

    49 Setting up the Daily Rainfall Alert 1. In Rain Mode, press ALARM/CHAR T to display rainfall alert. 2. Press and hold ALARM/CHAR T until rainfall alert and “ALARM HI” starts flashing in the display . 3. Set V alue for Rainfall Alert: Press the button [ ] or [ ] to adjust value. Press and hold either button for fast advance. Press ALARM/CHAR T ...

  • TFA 35.1075 - page 20

    50 Resetting the W ind Statistics Memor y In W ind Mode, press and hold MEMOR Y to reset all wind statistics. Activating/Deactivating Wind Alerts 1. In W ind Mode, each press of ALARM/CHART rotates wind speed display between: - Current wind speed - W ind speed alert (“ALARM HI” displayed) - Gust alert (“GUST ALARM HI” displayed) If the aler ...

  • TFA 35.1075 - page 21

    51 Rain Sensor Like all rain gauges, the rain sensor is prone to blockages due to its funnel shape. Checking and cleaning the rain sensor from time to time will maintain the accuracy of rain measurements. - Detach the protective screen and lid. Remove any dirt, leaves or debris by cleaning the items with soapy water and a damp cloth. Clean small ho ...

  • TFA 35.1075 - page 22

    52 PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully . Here are a few precautions: 1. Do not immerse the unit in water . 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. 3. Do not subject the unit to excessi ...

  • TFA 35.1075 - page 23

    53 TF A-Dostmann GmbH & Co.KG Zum Ottersberg 12 D-97877 W ertheim/Reicholzheim www .tfa-dostmann.de Power Main unit : use 4 pcs “AA” 1.5V battery : AC/DC adaptor 7.5V 200mA (centre +) Remote Thermo.-Hygro unit : use 2 pcs “AA” 1.5V battery Remote Anemometer unit : use 2 pcs “AA” 1.5V battery Remote Rain gauge unit : use 2 pcs “AA? ...

  • TFA 35.1075 - page 24

    54 Appendix City Codes US and Canadian Cities City Code Zone Offset DST City Code Zone Offset DST Atlanta, Ga. AT L - 5 S U Memphis, T enn. MEM -6 SU Austin, T ex. AUS -6 SU Miami, Fla. MIA -5 SU Baltimore, Md. BWI -5 SU Milwaukee, Wis. MKE -6 SU Birmingham, Ala. BHM -6 SU Minneapolis, Minn. MSP -6 SU Boston, Mass. BOS -5 SU Montreal, Que., Can. YM ...

  • TFA 35.1075 - page 25

    55 City Code T ime Zone DST City Code Time Zone DST Kinshasa, Congo FIH 1 NO Oslo, Norway OSL 1 SE Kuala Lumpur , Malaysia KUL 8 NO Panama City , Panama PTY -5 NO La Paz, Bolivia LPB -4 NO Paris, France PA R 1 SE Lima, Peru LIM -5 NO Perth, Australia PER 8 NO Lisbon, Portugal LIS 0 SE Prague, Czech Republic PRG 1 SE Liverpool, England LPL 0 SE Rang ...

  • TFA 35.1075 - page 26

    56 T echnical Specifications W eather Station Receivers Receiver (Supply=6.0V , T a=23 ° C) and Sensor unit (Supply=3.0V , T a=23 ° C) RF T ransmission Frequency 433.92 MHz RF Reception Range Thermo-hygro Sensor 100 meters Maximum (Line of Sight ) W ind Sensor, Rain Sensor 100 meters Maximum (Line of Sight) Barometric Pressure Range 500 hpa to 1 ...

  • TFA 35.1075 - page 27

    57 TE922 & TS34C IM2(ENG) TFA 11/5/08, 4:01 PM 57 ...

Fabricant TFA Catégorie Weather station

Les documents que nous recevons du fabricant de l'appareilTFA 35.1075 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques TFA
- manuels d’utilisations 35.1075
- fiches produit TFA
- dépliants
- ou étiquettes-énergie TFA 35.1075
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation TFA 35.1075.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation TFA 35.1075, manuels d’entretien, brefs manuels ou manuels de l’utilisateur TFA 35.1075. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit TFA 35.1075.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil TFA 35.1075, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser TFA 35.1075 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs TFA 35.1075.

Le manuel d’utilisation complet TFA, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel TFA 35.1075 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières TFA 35.1075, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTFA 35.1075 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil TFA 35.1075 - qui devraient nous aider dans les premières étapes lors de l'utilisation TFA 35.1075
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de TFA 35.1075
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service TFA 35.1075 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de TFA 35.1075?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec TFA 35.1075, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec TFA 35.1075 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (1)

Simon Veci Rocillo

Necesito las instrucciones en español, es posible