Manual TFA 35.1075

27 pages Not applicable
Download

Go to site of 27

Summary
  • TFA 35.1075 - page 1

    31 Nexus W eather Station ( Kat. Nr . 35.1075 ) Instruction Manual TE922 & TS34C IM2(ENG) TFA 11/5/08, 4:01 PM 31 ...

  • TFA 35.1075 - page 2

    32 Introduction Congratulations on your purchase of the “Nexus” W eather Station. The weather station consists of a main console unit, as well as an assortment of remote sensors which collect and transmit a wide range of weather data, including outdoor temperature, humidity , wind speed and direction, rain amount and rain rate. Main Console Uni ...

  • TFA 35.1075 - page 3

    33 Alarms - Single alarm : activated once at specified time - W eekday alarm : activated everyday from Monday to Friday at specified time - Pre-alarm : activated ahead of single or weekday alarm if channel 1 temperature falling to +2 ° C or below . (Fixed 30 minutes) - Programmable snooze function (1-15 minutes) Sunrise time and sunset time - Calc ...

  • TFA 35.1075 - page 4

    34 Contents of Complete W eather Station Kit Before installing your weather station, please check that the following are complete: Fittings Hardware Components AC/DC 7.5V output adaptor USB Main Console Unit Thermo-Hygro Sensor 4 screws for securing unit to ground Rain Sensor: - Funnel shaped Lid with Battery Hatch - Sensor Base - Bucket See - saw ...

  • TFA 35.1075 - page 5

    35 Installing your weather station Setting up the Remote W eather Sensors Before starting up the main console unit, setup all the remote sensors first. When placing the sensors, make sure that they are within receiving range of the console unit. Ideally they should be within the line of sight of the console unit. T ransmission range may be affected ...

  • TFA 35.1075 - page 6

    36 wind-blown rain, or create extra precipitation runoff. Trees and rooftops may also be sources of pollen and debris. - T o avoid rain shadow effects, place the sensor at a horizontal distance corresponding to two to four times the height of any nearby obstruction. - It is important that rain excess can flow freely away from the sensor . Make sure ...

  • TFA 35.1075 - page 7

    37 - Switches to next mode in anti-clockwise direction - Increment for setting parameters - Switches to next mode in clockwise direction - Decrement for setting parameters SET - Rotates display for current mode - Press and hold to enter setup or change units - Confirmation for setting parameters MEMOR Y - Shows records for moon phase, temperature, ...

  • TFA 35.1075 - page 8

    38 The following controls are only available on the main console unit: LIGHT SENSOR - AUTO, ON, OFF - T oggles the light sensor function to automatic, on or off SENSITIVITY - HIGH/LOW - Adjusts the sensitivity of the light sensor Navigating between Different Modes There are 7 modes available on the main console unit, and each one displays a differe ...

  • TFA 35.1075 - page 9

    39 T emperature and Humidity Mode - T emperature and humidity trend and readings for indoor and selected channel - Comfort level - Dew point - T emperature alerts Rain Mode - Precipitation amount for last hour , last 24 hour, yesterday , last week and last month - Rainfall alert Wind Mode - W ind Chill - T emperature at place of anemometer - W ind ...

  • TFA 35.1075 - page 10

    40 LED Backlight Options The backlight of the main console unit can be turned permanently on/off or automatically toggled when environment lighting level is low . Use the light sensor switch at the back of the unit to select lighting preferences. For the automatic backlight function, the sensitivity of the light sensor can be adjusted to high or lo ...

  • TFA 35.1075 - page 11

    41 V iewing Pressur e and Altitude Data In Pressure and W eather Forecast Mode, each press of SET rotates display between: - Sea level pressure - Local pressure - Local altitude Setting the Sea Level Pressur e 1. In Pressure and W eather Forecast Mode, press SET until the sea level pressure is displayed. 2. Press and hold SET . The Sea Level Pressu ...

  • TFA 35.1075 - page 12

    42 Understanding the W eather For ecast Display W eather For ecast Status Display and Sunny Partly Cloudy and Cloudy Light Rain and and Heavy Rain and Unstable W eather and Light Snow Heavy Snow and and and NOTE: 1. The accuracy of a general pr essur e-based weather forecast is about 70%. 2. The weather for ecasts. It may not necessarily r eflect t ...

  • TFA 35.1075 - page 13

    43 Understanding the Moon Phase Diagram Clock and Alarm Mode The main console unit can be configured to display the time, calendar or UTC time. There are three time alarms available on the console unit: Single alarm : activated once at specified time W eekday alarm : activated everyday from Monday to Friday at specified time Pre-alarm : activated a ...

  • TFA 35.1075 - page 14

    44 Rotating between Different Clock/Calendar Displays In Clock and Alarm Mode, each press of SET rotates clock display between: - Hour: Minute for UTC (Coordinated Universal T ime) - Hour: Minute: W eekday - Hour: Minute: City - Hour: Minute: Second - Month: Day: Y ear (or Day: Month Y ear depending on settings) Activating/Deactivating the T ime Al ...

  • TFA 35.1075 - page 15

    45 Icon RC Reception Strength (Flashing) Undefined data Reception failed for 24 hours W eak signal, but can be decoded Strong signal T o turn this function on/off: Press and hold the button [ ] . If RC reception is activated, a tower icon will start flashing beside the clock icon. If RC reception is deactivated, the triangular tower icon will disap ...

  • TFA 35.1075 - page 16

    46 4. Repeat above procedure to set minute of latitude, degree of longitude, minute of longitude, time zone of the city , and DST selection. 5. Upon completion the display will be returned to Sunrise/Sunset Mode. Note: Press and hold SET anytime during the setup to return to normal Clock and Alarm Mode. All settings made will be discarded. V iewing ...

  • TFA 35.1075 - page 17

    47 Accessing T emperature and Humidity Mode From the main console unit: Press the button [ ] or [ ] until the OUT Icon and IN icon on the upper right of the display starts flashing. V iewing T emperature and Humidity Display for each Channel For Static Display: In T emperature and Humidity Mode, each press of CHANNEL rotates display between differe ...

  • TFA 35.1075 - page 18

    48 Remote Sensor Status The wave icon above the current channel display shows the connection status of the corresponding remote sensor: Activating Main Console Unit to Search for All Remote Sensor Signals The main console unit may be manually activated to search for signals from all remote sensors. Press and hold the button [ ] to enforce a search. ...

  • TFA 35.1075 - page 19

    49 Setting up the Daily Rainfall Alert 1. In Rain Mode, press ALARM/CHAR T to display rainfall alert. 2. Press and hold ALARM/CHAR T until rainfall alert and “ALARM HI” starts flashing in the display . 3. Set V alue for Rainfall Alert: Press the button [ ] or [ ] to adjust value. Press and hold either button for fast advance. Press ALARM/CHAR T ...

  • TFA 35.1075 - page 20

    50 Resetting the W ind Statistics Memor y In W ind Mode, press and hold MEMOR Y to reset all wind statistics. Activating/Deactivating Wind Alerts 1. In W ind Mode, each press of ALARM/CHART rotates wind speed display between: - Current wind speed - W ind speed alert (“ALARM HI” displayed) - Gust alert (“GUST ALARM HI” displayed) If the aler ...

  • TFA 35.1075 - page 21

    51 Rain Sensor Like all rain gauges, the rain sensor is prone to blockages due to its funnel shape. Checking and cleaning the rain sensor from time to time will maintain the accuracy of rain measurements. - Detach the protective screen and lid. Remove any dirt, leaves or debris by cleaning the items with soapy water and a damp cloth. Clean small ho ...

  • TFA 35.1075 - page 22

    52 PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully . Here are a few precautions: 1. Do not immerse the unit in water . 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. 3. Do not subject the unit to excessi ...

  • TFA 35.1075 - page 23

    53 TF A-Dostmann GmbH & Co.KG Zum Ottersberg 12 D-97877 W ertheim/Reicholzheim www .tfa-dostmann.de Power Main unit : use 4 pcs “AA” 1.5V battery : AC/DC adaptor 7.5V 200mA (centre +) Remote Thermo.-Hygro unit : use 2 pcs “AA” 1.5V battery Remote Anemometer unit : use 2 pcs “AA” 1.5V battery Remote Rain gauge unit : use 2 pcs “AA? ...

  • TFA 35.1075 - page 24

    54 Appendix City Codes US and Canadian Cities City Code Zone Offset DST City Code Zone Offset DST Atlanta, Ga. AT L - 5 S U Memphis, T enn. MEM -6 SU Austin, T ex. AUS -6 SU Miami, Fla. MIA -5 SU Baltimore, Md. BWI -5 SU Milwaukee, Wis. MKE -6 SU Birmingham, Ala. BHM -6 SU Minneapolis, Minn. MSP -6 SU Boston, Mass. BOS -5 SU Montreal, Que., Can. YM ...

  • TFA 35.1075 - page 25

    55 City Code T ime Zone DST City Code Time Zone DST Kinshasa, Congo FIH 1 NO Oslo, Norway OSL 1 SE Kuala Lumpur , Malaysia KUL 8 NO Panama City , Panama PTY -5 NO La Paz, Bolivia LPB -4 NO Paris, France PA R 1 SE Lima, Peru LIM -5 NO Perth, Australia PER 8 NO Lisbon, Portugal LIS 0 SE Prague, Czech Republic PRG 1 SE Liverpool, England LPL 0 SE Rang ...

  • TFA 35.1075 - page 26

    56 T echnical Specifications W eather Station Receivers Receiver (Supply=6.0V , T a=23 ° C) and Sensor unit (Supply=3.0V , T a=23 ° C) RF T ransmission Frequency 433.92 MHz RF Reception Range Thermo-hygro Sensor 100 meters Maximum (Line of Sight ) W ind Sensor, Rain Sensor 100 meters Maximum (Line of Sight) Barometric Pressure Range 500 hpa to 1 ...

  • TFA 35.1075 - page 27

    57 TE922 & TS34C IM2(ENG) TFA 11/5/08, 4:01 PM 57 ...

Manufacturer TFA Category Weather station

Documents that we receive from a manufacturer of a TFA 35.1075 can be divided into several groups. They are, among others:
- TFA technical drawings
- 35.1075 manuals
- TFA product data sheets
- information booklets
- or energy labels TFA 35.1075
All of them are important, but the most important information from the point of view of use of the device are in the user manual TFA 35.1075.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals TFA 35.1075, service manual, brief instructions and user manuals TFA 35.1075. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product TFA 35.1075.

A complete manual for the device TFA 35.1075, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use TFA 35.1075 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of TFA 35.1075.

A complete TFA manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual TFA 35.1075 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the TFA 35.1075, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the TFA 35.1075, that we can find in the current document
3. Tips how to use the basic functions of the device TFA 35.1075 - which should help us in our first steps of using TFA 35.1075
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with TFA 35.1075
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of TFA 35.1075 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning TFA 35.1075?

Use the form below

If you did not solve your problem by using a manual TFA 35.1075, ask a question using the form below. If a user had a similar problem with TFA 35.1075 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (1)

Simon Veci Rocillo

Necesito las instrucciones en español, es posible