    NI UES-3880 Hardware Inst allation Guide First Edition, Sept 2007 P/N: 1802003080110 ...

  • National Instruments NI UES-3880 - page 2

    — 1 — Overview The NI UES-3880 is a smart Ethernet switch that provides an econom ical solution for your Ethernet connections . As an added bonus, the built-in smart alarm function helps system maintainers monitor the health of your Et hernet network. The NI UES-3880 has a wide operating tem perature range of -40 to 75ºC, and is designed to wi ...

  • National Instruments NI UES-3880 - page 3

    — 2 — Panel Layout V1 V2 INPUTS: 24 VDC PWR2 V2+ V2- V1- V1+ FAULT PWR1 12345678 ON DIP PORT ALARM T op Panel View 1 2 3 4 Rear Panel View 1 2 13 12 12 Front Panel View 8 9 10 2 5 6 7 11 1. Grounding screw 2. Terminal block for power inputs PWR1/PWR2 and relay output 3. Heat dissipation orifices 4. DIP switches 5. Power input PWR1 LED 6. Power ...

  • National Instruments NI UES-3880 - page 4

    — 3 — Mounting Dimensions (unit = mm) Rear View Side View Front View + + 9.75 13.90 5 10 10 26 6 Panel Mount Kit (unit = mm) 135.00 13.10 15.10 21.00 105.00 + + 25.40 13.90 18.20 25.71 23.15 7.75 30.50 7.75 + + + + + + + + + + 3.50 6.00 3.50 6.00 39.37 46.77 135.00 30.00 9.50 + + + + + + + + + + 54.00 13 18 13 ...

  • National Instruments NI UES-3880 - page 5

    — 4 — DIN-rail Mounting The aluminum DIN-rail attachment plat e should already be fixed to the back panel of the switch when you take it out of the box. If you need to reattach the DIN-rail attachment plate, make sure th e stiff metal spring is situated towards the top, as shown in the figures below. STEP 1 : Insert the top of th e DIN-rail int ...

  • National Instruments NI UES-3880 - page 6

    — 5 — STEP 3 : Once the screws are fixed in the wall, insert the four screw heads through the large parts of the keyhole-shaped apertures, and then slide the NI UES-3880 downwards, as indicated. Tighten the four screws for added stability. ⇒ Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switch ...

  • National Instruments NI UES-3880 - page 7

    — 6 — You should also pay attention to the following item s: y Use separate paths to route wiring fo r power and devices. I f power wiring and device wiring paths m ust cross, ma ke sure the wires are perpendicular at the intersection point. y NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid i ...

  • National Instruments NI UES-3880 - page 8

    — 7 — T op V iew Front View STEP 1 : Insert the negative/positive DC wires into the V-/V+ terminals. STEP 2 : To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3 : Insert the plastic terminal block connector prongs into the terminal blo ...

  • National Instruments NI UES-3880 - page 9

    — 8 — RJ45 (8-pin) to RJ45 (8 -pin) Cross-O ver Cable Wiring Cross-Over Cable RJ45 Plug Pin 1 Switch Port (NIC Port) RJ45 Connector RJ45 Connector Tx+ Tx- Rx+ Rx- (Rx+) (Rx-) (Tx+) (Tx-) (Tx+) (Tx-) (Rx+) (Rx-) Switch Port (NIC Port) Cable Wiring 3 1 6 2 1 3 2 6 Rx+ Rx- Tx+ Tx- Redundant Power Inputs Both power inputs can be connected sim u lta ...

  • National Instruments NI UES-3880 - page 10

    — 9 — LED Indicators The front panel of the NI Switch contai ns several LED indicators. T he function of each LED is described in the table below. LED Color State Description On Power is being supplied to power input PWR1 PWR1 AMBER Off Power is not being supplied to power input PWR1 On Power is being supplied to power input PWR2 PWR2 AMBER Off ...

  • National Instruments NI UES-3880 - page 11

    — 10 — where it is not needed. Packets that are used in maintaining the operation of the network (such as the occasional multi-cast packet) are fo rwarded to all ports. The NI UES-3880 operates in the store-and-for ward switching mode, which eliminates bad packets and enables p eak performance to be achieved when there is heavy traffic on the n ...

  • National Instruments NI UES-3880 - page 12

    — 11 — Specifications T echnology Standards IEEE802.3, 802. 3u, 802.3x Forward and Filtering Rate 148810 pps Packet Buffer Memory 256 KB Processing T ype Store and Forw ard, with IEEE802.3x full duple x, back pressure flow control Address T able Size 1K uni-cast addresses Latency Less than 5 μ s Interface RJ45 Ports 10/100BaseT(X) auto negotia ...

  • National Instruments NI UES-3880 - page 13

    — 12 — Technical Support and Professional Services Visit the following sections of th e National Instruments Web site at ni.com for technical support and professional services: • Support— Online technical support resources at ni.com/support include the following: Self-Help Resources— For answers and solutions, visit the award-winning Nati ...

  • National Instruments NI UES-3880 - page 14

    — 13 — Worldwide Technical Support and Product Infor mation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504USATe l: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 662 457 990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 34 88, China 86 21 5050 98 ...

Fabricant National Instruments Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilNational Instruments NI UES-3880 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations NI UES-3880
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments NI UES-3880
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments NI UES-3880.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments NI UES-3880, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments NI UES-3880. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments NI UES-3880.

Manuel d’utilisation complet de l’appareil National Instruments NI UES-3880, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments NI UES-3880 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments NI UES-3880.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments NI UES-3880 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments NI UES-3880, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments NI UES-3880 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments NI UES-3880 - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments NI UES-3880
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments NI UES-3880
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments NI UES-3880 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments NI UES-3880?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments NI UES-3880, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments NI UES-3880 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)