    NI UES-3880 Hardware Inst allation Guide First Edition, Sept 2007 P/N: 1802003080110 ...

  • National Instruments NI UES-3880 - page 2

    — 1 — Overview The NI UES-3880 is a smart Ethernet switch that provides an econom ical solution for your Ethernet connections . As an added bonus, the built-in smart alarm function helps system maintainers monitor the health of your Et hernet network. The NI UES-3880 has a wide operating tem perature range of -40 to 75ºC, and is designed to wi ...

  • National Instruments NI UES-3880 - page 3

    — 2 — Panel Layout V1 V2 INPUTS: 24 VDC PWR2 V2+ V2- V1- V1+ FAULT PWR1 12345678 ON DIP PORT ALARM T op Panel View 1 2 3 4 Rear Panel View 1 2 13 12 12 Front Panel View 8 9 10 2 5 6 7 11 1. Grounding screw 2. Terminal block for power inputs PWR1/PWR2 and relay output 3. Heat dissipation orifices 4. DIP switches 5. Power input PWR1 LED 6. Power ...

  • National Instruments NI UES-3880 - page 4

    — 3 — Mounting Dimensions (unit = mm) Rear View Side View Front View + + 9.75 13.90 5 10 10 26 6 Panel Mount Kit (unit = mm) 135.00 13.10 15.10 21.00 105.00 + + 25.40 13.90 18.20 25.71 23.15 7.75 30.50 7.75 + + + + + + + + + + 3.50 6.00 3.50 6.00 39.37 46.77 135.00 30.00 9.50 + + + + + + + + + + 54.00 13 18 13 ...

  • National Instruments NI UES-3880 - page 5

    — 4 — DIN-rail Mounting The aluminum DIN-rail attachment plat e should already be fixed to the back panel of the switch when you take it out of the box. If you need to reattach the DIN-rail attachment plate, make sure th e stiff metal spring is situated towards the top, as shown in the figures below. STEP 1 : Insert the top of th e DIN-rail int ...

  • National Instruments NI UES-3880 - page 6

    — 5 — STEP 3 : Once the screws are fixed in the wall, insert the four screw heads through the large parts of the keyhole-shaped apertures, and then slide the NI UES-3880 downwards, as indicated. Tighten the four screws for added stability. ⇒ Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switch ...

  • National Instruments NI UES-3880 - page 7

    — 6 — You should also pay attention to the following item s: y Use separate paths to route wiring fo r power and devices. I f power wiring and device wiring paths m ust cross, ma ke sure the wires are perpendicular at the intersection point. y NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid i ...

  • National Instruments NI UES-3880 - page 8

    — 7 — T op V iew Front View STEP 1 : Insert the negative/positive DC wires into the V-/V+ terminals. STEP 2 : To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3 : Insert the plastic terminal block connector prongs into the terminal blo ...

  • National Instruments NI UES-3880 - page 9

    — 8 — RJ45 (8-pin) to RJ45 (8 -pin) Cross-O ver Cable Wiring Cross-Over Cable RJ45 Plug Pin 1 Switch Port (NIC Port) RJ45 Connector RJ45 Connector Tx+ Tx- Rx+ Rx- (Rx+) (Rx-) (Tx+) (Tx-) (Tx+) (Tx-) (Rx+) (Rx-) Switch Port (NIC Port) Cable Wiring 3 1 6 2 1 3 2 6 Rx+ Rx- Tx+ Tx- Redundant Power Inputs Both power inputs can be connected sim u lta ...

  • National Instruments NI UES-3880 - page 10

    — 9 — LED Indicators The front panel of the NI Switch contai ns several LED indicators. T he function of each LED is described in the table below. LED Color State Description On Power is being supplied to power input PWR1 PWR1 AMBER Off Power is not being supplied to power input PWR1 On Power is being supplied to power input PWR2 PWR2 AMBER Off ...

  • National Instruments NI UES-3880 - page 11

    — 10 — where it is not needed. Packets that are used in maintaining the operation of the network (such as the occasional multi-cast packet) are fo rwarded to all ports. The NI UES-3880 operates in the store-and-for ward switching mode, which eliminates bad packets and enables p eak performance to be achieved when there is heavy traffic on the n ...

  • National Instruments NI UES-3880 - page 12

    — 11 — Specifications T echnology Standards IEEE802.3, 802. 3u, 802.3x Forward and Filtering Rate 148810 pps Packet Buffer Memory 256 KB Processing T ype Store and Forw ard, with IEEE802.3x full duple x, back pressure flow control Address T able Size 1K uni-cast addresses Latency Less than 5 μ s Interface RJ45 Ports 10/100BaseT(X) auto negotia ...

  • National Instruments NI UES-3880 - page 13

    — 12 — Technical Support and Professional Services Visit the following sections of th e National Instruments Web site at ni.com for technical support and professional services: • Support— Online technical support resources at ni.com/support include the following: Self-Help Resources— For answers and solutions, visit the award-winning Nati ...

  • National Instruments NI UES-3880 - page 14

    — 13 — Worldwide Technical Support and Product Infor mation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504USATe l: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 662 457 990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 34 88, China 86 21 5050 98 ...

Manufacturer National Instruments Category Switch

Documents that we receive from a manufacturer of a National Instruments NI UES-3880 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- NI UES-3880 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments NI UES-3880
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments NI UES-3880.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments NI UES-3880, service manual, brief instructions and user manuals National Instruments NI UES-3880. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments NI UES-3880.

A complete manual for the device National Instruments NI UES-3880, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments NI UES-3880 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments NI UES-3880.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments NI UES-3880 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments NI UES-3880, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments NI UES-3880, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments NI UES-3880 - which should help us in our first steps of using National Instruments NI UES-3880
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments NI UES-3880
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments NI UES-3880 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments NI UES-3880?

Use the form below

If you did not solve your problem by using a manual National Instruments NI UES-3880, ask a question using the form below. If a user had a similar problem with National Instruments NI UES-3880 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)