Manuel d’utilisation Hunter 40170

33 pages 1.18 mb
Télécharger

Aller à la page of 33

Summary
  • Hunter 40170 - page 1

    Ele c tr on ic/M e chani c al er most a t Mo d el 40170 ins t allat ion and op erat ion manual 42998-01 01-19-2007 ...

  • Hunter 40170 - page 2

    2 ...

  • Hunter 40170 - page 3

    3 T able of Contents Important Information.................................................. 5 T ools ............................................................................ 6 Uninstalling the Existing Unit ...................................... 9 Installing the T hermostat ........................................... 13 installing the w all pl ...

  • Hunter 40170 - page 4

    4 Congratulations! T hank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year -round energy savings . Please read this manual before beginning installation and save this booklet for complete operation instructions . Electr onic/Mechanical Thermostat Model 40170 ...

  • Hunter 40170 - page 5

    5 T his thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – F ired Boilers Gas – Millivolt Systems Oil – F ired Boilers Oil – F ired Furnace Electric Furnace Electric Air Conditioning Single-stage Heat Pump Systems T his thermostat is not designed for Multi-st ...

  • Hunter 40170 - page 6

    6 T his thermostat includes two #8 slotted screws and two w all anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ............................................................................................. Small Phillips-head screwdriver ............................................. ...

  • Hunter 40170 - page 7

    7 NO TICE! Do not disconnect the wir es fr om the existing thermostat before r eading these instructions . The wires must be labeled prior to r emoval to ensur e proper r econnection. ...

  • Hunter 40170 - page 8

    8 UNINST ALLING THE EXISTING UNIT Y RC G W Y RC G W ...

  • Hunter 40170 - page 9

    9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV A C system OFF at the main power panel or at the furnace . 2. Remove the existing thermostat cover to access the wires from the w all. (Some thermostats may have multiple covers , screws or other locking devices that must be removed or disengaged.) 3. Locate , b ...

  • Hunter 40170 - page 10

    10 UNINST ALLING THE EXISTING UNIT , CONT . if your existing thermostat is marked ... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / VC RC RC RH / R / VR / 4 RH RH 24 V olt 24 V olt cool air conditioning compressor heating fan O O O reversing valve cool B B B reversing valve heat ...

  • Hunter 40170 - page 11

    11 4. Using the provided stick ers , label each wire according to the chart. (If the terminals are not labeled, contact a qualified HV A C technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires mark ed Y & C are both p ...

  • Hunter 40170 - page 12

    12 T op Cover T hermostat ...

  • Hunter 40170 - page 13

    13 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the top cover from the new thermostat by pulling the two halves apart. ...

  • Hunter 40170 - page 14

    14 W RC Y G ...

  • Hunter 40170 - page 15

    15 2. P osition the new thermostat on the w all and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter w all plate , or if there are no existing holes , level the thermostat and mark the w all for two holes . 4. Remove the thermostat and drill two 3/16” holes where mark ed. 5. T ap the plastic an ...

  • Hunter 40170 - page 16

    16 INST ALLING THE THERMOST A T , CONT . G RC RH Y W B O R H R C W G B O Y ...

  • Hunter 40170 - page 17

    17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove , the terminal screws . Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper . If you do not have both an RH and RC wire, leave ...

  • Hunter 40170 - page 18

    18 INST ALLING THE THERMOST A T , CONT . HG HE HP STD HE/HG Switch HP/STD Switch ...

  • Hunter 40170 - page 19

    19 A TT A CHING THE THERMOST A T 1. Locate the HE/HG switch on the w all plate . Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces . (T he switch has no effect when the system is set to cooling mode .) 2. Locate the HP/STD switch on the w all plate . Set the switch to HP for Single-stage heat pump sys ...

  • Hunter 40170 - page 20

    20 INST ALLING THE THERMOST A T , CONT . ...

  • Hunter 40170 - page 21

    21 3. Insert two fresh AA alkaline batteries . 4. Align the top cover with the the w all plate , and snap the two halves together . 5. Restore power at the electrical panel or furnace . INST ALLING THE THERMOST A T , CONT . ...

  • Hunter 40170 - page 22

    22 AUT O ON COOL OFF HEA T SYSTEM 9 0 0 7 0 6 0 5 8 0 F an Switch System Switch Set T emperature Slider ...

  • Hunter 40170 - page 23

    23 OPERA TION 1. Set the Set Temperature slider to the desired temperature . 2. T he System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. T he Fan Switch should normally be located in the Auto position. T o run the fan continuously , slide the Fan Switch to the On position. Note: In Auto , The fan will be tur ...

  • Hunter 40170 - page 24

    24 INDICA TORS AND ADUSTMENT 0 5 0 6 0 7 8 0 9 0 T hermometer Battery Indicator ...

  • Hunter 40170 - page 25

    25 INDICA TORS AND ADUSTMENT 1. T he Thermometer indicates the room temperature . 2. T he Battery Indicator displays two battery conditions . T he first w arning is the Weak Battery Warning , indicated by the Battery Indicator flashing once approximately every three seconds . When this w arning appears , install two fresh AA alkaline batteries at ...

  • Hunter 40170 - page 26

    26 SP AN Span Adjust SP AN ...

  • Hunter 40170 - page 27

    27 INDICA TORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o mak e your system run LONGER, turn the Span Adjust clockwise . 3. T o mak e your system run SHOR TER, turn the Span Adjust counter clockwise . 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6 o F - 3 o F . The Span setting remains the ...

  • Hunter 40170 - page 28

    28 1. My heating or cooling will not turn on or off . 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b . W ait. T here may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit break ers and switches to ensure there is enough power to the system. 1 d. Replace ...

  • Hunter 40170 - page 29

    29 Is there help on the web? Y es . V isit http://www .hunterfan.com for more information. ............................................................................................. Can’t I just call someone? Sure . Our T echnical Support Group is av ailable from 8 am to 5 pm CST . T hey may be reached toll-free at 1-888-830-1326. TROUBLESHOOT ...

  • Hunter 40170 - page 30

    30 G Rc Rh W Y F an Relay Heat/C ool 24V Supply Cool Contactor Heat Rela y or V alve X Jumper 4-wire Heat/C ool System G Rc Rh F an Relay He at 24V Supply W Heat Relay or V alve Y Cool Contactor 5-wire Heat/C ool System Cool 24V Supply ...

  • Hunter 40170 - page 31

    31 WIRING DIAGRAMS Reversing V alve Compressor Contactor X F an Relay Heat/C ool 24V Supply Single-stage Heat P ump System Cool Mode Heat Mode OR W G Rc Rh O B Y X Jumper Rc R h W Heat 24V or Millivolt Supply Heat Relay or V alv e X Jumper 2-wire Heat Onl y System ...

  • Hunter 40170 - page 32

    32 G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire C ool Only System F an Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire C ool Only System F ...

  • Hunter 40170 - page 33

    33 © 2007 Hunter F an Company ...

Fabricant Hunter Catégorie Thermostat

Les documents que nous recevons du fabricant de l'appareilHunter 40170 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Hunter
- manuels d’utilisations 40170
- fiches produit Hunter
- dépliants
- ou étiquettes-énergie Hunter 40170
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Hunter 40170.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Hunter 40170, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Hunter 40170. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Hunter 40170.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Hunter 40170, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Hunter 40170 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Hunter 40170.

Le manuel d’utilisation complet Hunter, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Hunter 40170 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Hunter 40170, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHunter 40170 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Hunter 40170 - qui devraient nous aider dans les premières étapes lors de l'utilisation Hunter 40170
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Hunter 40170
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Hunter 40170 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Hunter 40170?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Hunter 40170, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Hunter 40170 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)