Manuale per l’uso Hunter 40170

33 pagine 1.18 mb
Scarica

Vai alla pagina of 33

Summary
  • Hunter 40170 - page 1

    Ele c tr on ic/M e chani c al er most a t Mo d el 40170 ins t allat ion and op erat ion manual 42998-01 01-19-2007 ...

  • Hunter 40170 - page 2

    2 ...

  • Hunter 40170 - page 3

    3 T able of Contents Important Information.................................................. 5 T ools ............................................................................ 6 Uninstalling the Existing Unit ...................................... 9 Installing the T hermostat ........................................... 13 installing the w all pl ...

  • Hunter 40170 - page 4

    4 Congratulations! T hank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year -round energy savings . Please read this manual before beginning installation and save this booklet for complete operation instructions . Electr onic/Mechanical Thermostat Model 40170 ...

  • Hunter 40170 - page 5

    5 T his thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – F ired Boilers Gas – Millivolt Systems Oil – F ired Boilers Oil – F ired Furnace Electric Furnace Electric Air Conditioning Single-stage Heat Pump Systems T his thermostat is not designed for Multi-st ...

  • Hunter 40170 - page 6

    6 T his thermostat includes two #8 slotted screws and two w all anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ............................................................................................. Small Phillips-head screwdriver ............................................. ...

  • Hunter 40170 - page 7

    7 NO TICE! Do not disconnect the wir es fr om the existing thermostat before r eading these instructions . The wires must be labeled prior to r emoval to ensur e proper r econnection. ...

  • Hunter 40170 - page 8

    8 UNINST ALLING THE EXISTING UNIT Y RC G W Y RC G W ...

  • Hunter 40170 - page 9

    9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV A C system OFF at the main power panel or at the furnace . 2. Remove the existing thermostat cover to access the wires from the w all. (Some thermostats may have multiple covers , screws or other locking devices that must be removed or disengaged.) 3. Locate , b ...

  • Hunter 40170 - page 10

    10 UNINST ALLING THE EXISTING UNIT , CONT . if your existing thermostat is marked ... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / VC RC RC RH / R / VR / 4 RH RH 24 V olt 24 V olt cool air conditioning compressor heating fan O O O reversing valve cool B B B reversing valve heat ...

  • Hunter 40170 - page 11

    11 4. Using the provided stick ers , label each wire according to the chart. (If the terminals are not labeled, contact a qualified HV A C technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires mark ed Y & C are both p ...

  • Hunter 40170 - page 12

    12 T op Cover T hermostat ...

  • Hunter 40170 - page 13

    13 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the top cover from the new thermostat by pulling the two halves apart. ...

  • Hunter 40170 - page 14

    14 W RC Y G ...

  • Hunter 40170 - page 15

    15 2. P osition the new thermostat on the w all and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter w all plate , or if there are no existing holes , level the thermostat and mark the w all for two holes . 4. Remove the thermostat and drill two 3/16” holes where mark ed. 5. T ap the plastic an ...

  • Hunter 40170 - page 16

    16 INST ALLING THE THERMOST A T , CONT . G RC RH Y W B O R H R C W G B O Y ...

  • Hunter 40170 - page 17

    17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove , the terminal screws . Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper . If you do not have both an RH and RC wire, leave ...

  • Hunter 40170 - page 18

    18 INST ALLING THE THERMOST A T , CONT . HG HE HP STD HE/HG Switch HP/STD Switch ...

  • Hunter 40170 - page 19

    19 A TT A CHING THE THERMOST A T 1. Locate the HE/HG switch on the w all plate . Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces . (T he switch has no effect when the system is set to cooling mode .) 2. Locate the HP/STD switch on the w all plate . Set the switch to HP for Single-stage heat pump sys ...

  • Hunter 40170 - page 20

    20 INST ALLING THE THERMOST A T , CONT . ...

  • Hunter 40170 - page 21

    21 3. Insert two fresh AA alkaline batteries . 4. Align the top cover with the the w all plate , and snap the two halves together . 5. Restore power at the electrical panel or furnace . INST ALLING THE THERMOST A T , CONT . ...

  • Hunter 40170 - page 22

    22 AUT O ON COOL OFF HEA T SYSTEM 9 0 0 7 0 6 0 5 8 0 F an Switch System Switch Set T emperature Slider ...

  • Hunter 40170 - page 23

    23 OPERA TION 1. Set the Set Temperature slider to the desired temperature . 2. T he System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. T he Fan Switch should normally be located in the Auto position. T o run the fan continuously , slide the Fan Switch to the On position. Note: In Auto , The fan will be tur ...

  • Hunter 40170 - page 24

    24 INDICA TORS AND ADUSTMENT 0 5 0 6 0 7 8 0 9 0 T hermometer Battery Indicator ...

  • Hunter 40170 - page 25

    25 INDICA TORS AND ADUSTMENT 1. T he Thermometer indicates the room temperature . 2. T he Battery Indicator displays two battery conditions . T he first w arning is the Weak Battery Warning , indicated by the Battery Indicator flashing once approximately every three seconds . When this w arning appears , install two fresh AA alkaline batteries at ...

  • Hunter 40170 - page 26

    26 SP AN Span Adjust SP AN ...

  • Hunter 40170 - page 27

    27 INDICA TORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o mak e your system run LONGER, turn the Span Adjust clockwise . 3. T o mak e your system run SHOR TER, turn the Span Adjust counter clockwise . 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6 o F - 3 o F . The Span setting remains the ...

  • Hunter 40170 - page 28

    28 1. My heating or cooling will not turn on or off . 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b . W ait. T here may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit break ers and switches to ensure there is enough power to the system. 1 d. Replace ...

  • Hunter 40170 - page 29

    29 Is there help on the web? Y es . V isit http://www .hunterfan.com for more information. ............................................................................................. Can’t I just call someone? Sure . Our T echnical Support Group is av ailable from 8 am to 5 pm CST . T hey may be reached toll-free at 1-888-830-1326. TROUBLESHOOT ...

  • Hunter 40170 - page 30

    30 G Rc Rh W Y F an Relay Heat/C ool 24V Supply Cool Contactor Heat Rela y or V alve X Jumper 4-wire Heat/C ool System G Rc Rh F an Relay He at 24V Supply W Heat Relay or V alve Y Cool Contactor 5-wire Heat/C ool System Cool 24V Supply ...

  • Hunter 40170 - page 31

    31 WIRING DIAGRAMS Reversing V alve Compressor Contactor X F an Relay Heat/C ool 24V Supply Single-stage Heat P ump System Cool Mode Heat Mode OR W G Rc Rh O B Y X Jumper Rc R h W Heat 24V or Millivolt Supply Heat Relay or V alv e X Jumper 2-wire Heat Onl y System ...

  • Hunter 40170 - page 32

    32 G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire C ool Only System F an Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire C ool Only System F ...

  • Hunter 40170 - page 33

    33 © 2007 Hunter F an Company ...

Fabbricante Hunter Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoHunter 40170 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Hunter
- manuali per l’uso 40170
- schede prodotto Hunter
- opuscoli
- o etichette energetiche Hunter 40170
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Hunter 40170.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Hunter 40170, manuali di manutenzione, brevi manuali o manuali utente Hunter 40170. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Hunter 40170.

Manuali per l’uso simili

Manuale completo del dispositivo Hunter 40170, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Hunter 40170 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Hunter 40170.

Il manuale per l’uso completo Hunter, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Hunter 40170 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Hunter 40170, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Hunter 40170 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Hunter 40170 - che ci dovrebbe aiutare nei primi passi durante l'uso Hunter 40170
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Hunter 40170
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Hunter 40170 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Hunter 40170?

Utilizza il modulo sottostante

Se non hai risolto il problema con Hunter 40170 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Hunter 40170 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)