Manuel d’utilisation Baldor DTM8000

24 pages 0.37 mb
Télécharger

Aller à la page of 24

Summary
  • Baldor DTM8000 - page 1

    DTM8000 Digital Tachometer Installation and Operating Manual LT49 (A-5-3196A) MN1327 ...

  • Baldor DTM8000 - page 2

    Quick Jump What models and recommended accessories are available? See p age 3. Looking for det ailed specifications? See p age 3. W ant to get st arted fast? See basic electrical hook-up det ails on p age 5. See mechanical inst allation det ails on p age 4. See some sample applications st arting on page 15. Need Help? See troubleshooting on p age 1 ...

  • Baldor DTM8000 - page 3

    1 T able of Content s Introduction ................................................................................................................... .................... 2 General Features .............................................................................................................................. 2 Models & Options ......... ...

  • Baldor DTM8000 - page 4

    2 Introduction The DTM8000 Digital Meter is a powerful, microprocessor-based unit capable of being configured for a number of todays demanding measurement needs. It can be quickly configured to operate as a digital rate meter, timer, or feature-filled process counter. It also offers up to two alarm outputs which can be adjusted for a number of t ...

  • Baldor DTM8000 - page 5

    3 Line Inp ut Vo lta g e-------------------- ---------------------------------- ---------------------------- Any Vo lta ge fro m 8 5 -26 5 VA C Line Inp ut Fre qu e nc y -------------------------------------- ---------------------------------- --------- Any F re q. fro m 48 -6 2 H e rt z Signal Inpu t Fre que ncy Range ----------------------------- ...

  • Baldor DTM8000 - page 6

    4 Mechanical Inst allation Exploded Panel View Cut-out and Mounting Dimensions 5.000" 4.625" 2.289" 1.656" Ta c h Ite m V alu Pag e T ACHOMETER ENTER 4.000" 4.000" HOUSING DEPTH 4.625" P ANEL CUT -OUT DTM8000-6 3.622 " .140 " x 2 1.770" 0.885" SUPPLIED WITH EA CH CONTROL: 1) GASKET 2) (2) 6-32 ...

  • Baldor DTM8000 - page 7

    5 Electrical Inst allation & Diagrams P1 T erminal Block Wiring Diagram P1 T erminal Block Descriptions P1-1 (2NC)  This is the normally-closed contact of the second user assignable relay output. P1-2 (2C)  This is the common contact of the second user assignable relay. P1-3 (2NO)  This is the normally-open contact of the second user a ...

  • Baldor DTM8000 - page 8

    6 Ta c h Ite m V alu Pag e T A CHOMETER ENTER Display Windo w Up & Down Buttons ENTER (Select) Button Basic Operating Instructions Rate, Time, and Counter Modes Explained In Rate Mode, the DTM8000 measures the input frequency, converts it to the user-defined units, and displays the rate in the display window of the user interface. Most applicat ...

  • Baldor DTM8000 - page 9

    7 Running Mode is the default display of the unit when power is applied. In Running Mode, the display shows the measured value in the appropriate user-defined format of rate, time, or count. As the input signal changes, the display is continuously updated to show the latest measurement. In this display mode, the Up and Down buttons serve no functio ...

  • Baldor DTM8000 - page 10

    8 Para meter Description Value R ange (units) Factory Settin gs User Settin gs 0 Selecting this item exits to Running Mode n/a n/a Read-Onl y Parameters 1 Model Number n/a 80 2 Software Build 1 – 9999 n/a 3 Hardware Version 1 – 9999 n/a 4 Serial Number – Major (reserved) n/a n/a 5 Serial Number – Minor (rese rved) n/a n/a General Setup 10 O ...

  • Baldor DTM8000 - page 11

    9 Sof tware Parameters, cont'd Para meter Description Value Range (units) Factory Settings User Settings Alarm Output #1 Conf iguration 40 Activation Conditions 0 – Alwa ys Off 1 – Always On 2 – Active when Above 3 – Active when Below 4 – Active inside Range 5 – Active outside Range 0 41 Output Style & Reset Mode 1 – Constant ...

  • Baldor DTM8000 - page 12

    10 Parameter Descriptions Parameter 0  Exit to Running Mode When parameter 0 is selected in Parameter-Selection Mode, the unit will return to Running Mode and display the running value. This should be selected once changes to parameters are completed. Parameter 1  Model Number (Read Only) This is a number which represents the base model numbe ...

  • Baldor DTM8000 - page 13

    11 Mode 3: Falling Edge, Prescaler = 4 In this mode, the signal input is measured at every 4th falling edge. This mode is especially useful when the signal input frequency is beyond the native pulse-per-minute range of the DTM8000. Because unit will automatically compensates for the prescaler, there is no need to factor in the prescaler value when ...

  • Baldor DTM8000 - page 14

    12 Parameter 25  Signal Input 1 (S1) Decimal Point (DP) Position This selects the format of the display with respect to the decimal points position. This parameter does not effect the value entry for other parameters. For example, it the user desires to display 10.00 at an input of 300RPM, then parameter 20 would be set to 1000, parameter 21 ...

  • Baldor DTM8000 - page 15

    13 Mode 3: Active When Display Value Below Limit The alarm output will activate when the displayed value is below the lower limit settings, parameters 47 and 57 accordingly. Mode 4: Active When Display Value Inside Range The alarm output will activate when the displayed value is greater than or equal to lower limit settings and less than or equal t ...

  • Baldor DTM8000 - page 16

    14 Parameter 45 & 55  Alarm 1 & 2 Pulse off Time This parameter defines the number of seconds the output should be disabled during the off phase of an active pulsing alarms output. Parameter 46 & 56  Alarm 1 & 2 Pulse Count This setting determines how many pulses are output when the alarm is activated and is configure ...

  • Baldor DTM8000 - page 17

    15 Application Examples Pump Flow Monitor with Audible and Visual Alarm Description: A pump monitor which displays the pump rate in gallons per minute with an audible and visual alarm output which will warn the operator of excessively low flow conditions under 5.00 GPM. The alarm should not be able to be silenced and should be reset when any front- ...

  • Baldor DTM8000 - page 18

    16 Conveyor Oven T ime Monitor with Over-Heating Alarm Description: An oven monitor displaying the tunnel time in minutes and seconds. The tunnel time is defined as the time it takes for the heated object on the conveyor to travel from point A to point B in the application diagram below. A visual indicator should activate if the tunnel time r ...

  • Baldor DTM8000 - page 19

    17 T ake-up / Pay-out Reel Material Measurement with Alarm Description: A take-up / pay-out system where the DTM8000 displays a measurement of dispensed or accumulated material in linear yards. Once the desired amount of material, 1500 yards, has been dispensed or accumulated, an external light should illuminate to indicate that the specified mater ...

  • Baldor DTM8000 - page 20

    18 Bi-directional Increment al Position Display Description: A system is needed which will track the position of a bi-directional linear-motion platform and allow the user to select a home or zero position. The display should read in inches and indicate the position of the platform at all times. Application Diagram: Wiring Diagram: Parameter Config ...

  • Baldor DTM8000 - page 21

    19 Problem Po ssible Case Solution Dis play is blank Power not appl ie d Defec t ive unit Using a v olt me ter, ver ify t hat a vol tage between 85 and 265VA C is measure d bet ween the L and N terminal bl oc k posi t ions. Contact t echnic al support for addi tional help and i nstr uc tio ns. Dis pl ay is dim Dis pl ay i nt ensit y paramet er is t ...

  • Baldor DTM8000 - page 22

    20 - Notes - ...

  • Baldor DTM8000 - page 23

    21 - Notes - ...

  • Baldor DTM8000 - page 24

    BALDOR ELECTRIC COMP ANY P .O. Box 2400 Ft. Smith, AR 72902–2400 (479) 646–471 1 Fax (479) 648–5792 www .baldor .com  Baldor Electric Company MN1327 Printed in USA 04/03 CH TEL: +41 52 647 4700 F AX: +41 52 659 2394 D TEL: +49 89 90 50 80 F AX: +49 89 90 50 8491 UK TEL: +44 1454 850000 F AX: +44 1454 859001 I TEL: +39 1 1 562 4440 F AX: +3 ...

Fabricant Baldor Catégorie Automobile Parts

Les documents que nous recevons du fabricant de l'appareilBaldor DTM8000 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Baldor
- manuels d’utilisations DTM8000
- fiches produit Baldor
- dépliants
- ou étiquettes-énergie Baldor DTM8000
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Baldor DTM8000.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Baldor DTM8000, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Baldor DTM8000. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Baldor DTM8000.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Baldor DTM8000, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Baldor DTM8000 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Baldor DTM8000.

Le manuel d’utilisation complet Baldor, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Baldor DTM8000 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Baldor DTM8000, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBaldor DTM8000 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Baldor DTM8000 - qui devraient nous aider dans les premières étapes lors de l'utilisation Baldor DTM8000
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Baldor DTM8000
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Baldor DTM8000 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Baldor DTM8000?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Baldor DTM8000, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Baldor DTM8000 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (1)

Maurizio

Buongiorno non riesco a scaricare il manuale in italiano di Allen & Heath 10fX grazie mkiage