  • Baldor DTM8000 - page 1

    DTM8000 Digital Tachometer Installation and Operating Manual LT49 (A-5-3196A) MN1327 ...

  • Baldor DTM8000 - page 2

    Quick Jump What models and recommended accessories are available? See p age 3. Looking for det ailed specifications? See p age 3. W ant to get st arted fast? See basic electrical hook-up det ails on p age 5. See mechanical inst allation det ails on p age 4. See some sample applications st arting on page 15. Need Help? See troubleshooting on p age 1 ...

  • Baldor DTM8000 - page 3

    1 T able of Content s Introduction ................................................................................................................... .................... 2 General Features .............................................................................................................................. 2 Models & Options ......... ...

  • Baldor DTM8000 - page 4

    2 Introduction The DTM8000 Digital Meter is a powerful, microprocessor-based unit capable of being configured for a number of todays demanding measurement needs. It can be quickly configured to operate as a digital rate meter, timer, or feature-filled process counter. It also offers up to two alarm outputs which can be adjusted for a number of t ...

  • Baldor DTM8000 - page 5

    3 Line Inp ut Vo lta g e-------------------- ---------------------------------- ---------------------------- Any Vo lta ge fro m 8 5 -26 5 VA C Line Inp ut Fre qu e nc y -------------------------------------- ---------------------------------- --------- Any F re q. fro m 48 -6 2 H e rt z Signal Inpu t Fre que ncy Range ----------------------------- ...

  • Baldor DTM8000 - page 6

    4 Mechanical Inst allation Exploded Panel View Cut-out and Mounting Dimensions 5.000" 4.625" 2.289" 1.656" Ta c h Ite m V alu Pag e T ACHOMETER ENTER 4.000" 4.000" HOUSING DEPTH 4.625" P ANEL CUT -OUT DTM8000-6 3.622 " .140 " x 2 1.770" 0.885" SUPPLIED WITH EA CH CONTROL: 1) GASKET 2) (2) 6-32 ...

  • Baldor DTM8000 - page 7

    5 Electrical Inst allation & Diagrams P1 T erminal Block Wiring Diagram P1 T erminal Block Descriptions P1-1 (2NC)  This is the normally-closed contact of the second user assignable relay output. P1-2 (2C)  This is the common contact of the second user assignable relay. P1-3 (2NO)  This is the normally-open contact of the second user a ...

  • Baldor DTM8000 - page 8

    6 Ta c h Ite m V alu Pag e T A CHOMETER ENTER Display Windo w Up & Down Buttons ENTER (Select) Button Basic Operating Instructions Rate, Time, and Counter Modes Explained In Rate Mode, the DTM8000 measures the input frequency, converts it to the user-defined units, and displays the rate in the display window of the user interface. Most applicat ...

  • Baldor DTM8000 - page 9

    7 Running Mode is the default display of the unit when power is applied. In Running Mode, the display shows the measured value in the appropriate user-defined format of rate, time, or count. As the input signal changes, the display is continuously updated to show the latest measurement. In this display mode, the Up and Down buttons serve no functio ...

  • Baldor DTM8000 - page 10

    8 Para meter Description Value R ange (units) Factory Settin gs User Settin gs 0 Selecting this item exits to Running Mode n/a n/a Read-Onl y Parameters 1 Model Number n/a 80 2 Software Build 1 – 9999 n/a 3 Hardware Version 1 – 9999 n/a 4 Serial Number – Major (reserved) n/a n/a 5 Serial Number – Minor (rese rved) n/a n/a General Setup 10 O ...

  • Baldor DTM8000 - page 11

    9 Sof tware Parameters, cont'd Para meter Description Value Range (units) Factory Settings User Settings Alarm Output #1 Conf iguration 40 Activation Conditions 0 – Alwa ys Off 1 – Always On 2 – Active when Above 3 – Active when Below 4 – Active inside Range 5 – Active outside Range 0 41 Output Style & Reset Mode 1 – Constant ...

  • Baldor DTM8000 - page 12

    10 Parameter Descriptions Parameter 0  Exit to Running Mode When parameter 0 is selected in Parameter-Selection Mode, the unit will return to Running Mode and display the running value. This should be selected once changes to parameters are completed. Parameter 1  Model Number (Read Only) This is a number which represents the base model numbe ...

  • Baldor DTM8000 - page 13

    11 Mode 3: Falling Edge, Prescaler = 4 In this mode, the signal input is measured at every 4th falling edge. This mode is especially useful when the signal input frequency is beyond the native pulse-per-minute range of the DTM8000. Because unit will automatically compensates for the prescaler, there is no need to factor in the prescaler value when ...

  • Baldor DTM8000 - page 14

    12 Parameter 25  Signal Input 1 (S1) Decimal Point (DP) Position This selects the format of the display with respect to the decimal points position. This parameter does not effect the value entry for other parameters. For example, it the user desires to display 10.00 at an input of 300RPM, then parameter 20 would be set to 1000, parameter 21 ...

  • Baldor DTM8000 - page 15

    13 Mode 3: Active When Display Value Below Limit The alarm output will activate when the displayed value is below the lower limit settings, parameters 47 and 57 accordingly. Mode 4: Active When Display Value Inside Range The alarm output will activate when the displayed value is greater than or equal to lower limit settings and less than or equal t ...

  • Baldor DTM8000 - page 16

    14 Parameter 45 & 55  Alarm 1 & 2 Pulse off Time This parameter defines the number of seconds the output should be disabled during the off phase of an active pulsing alarms output. Parameter 46 & 56  Alarm 1 & 2 Pulse Count This setting determines how many pulses are output when the alarm is activated and is configure ...

  • Baldor DTM8000 - page 17

    15 Application Examples Pump Flow Monitor with Audible and Visual Alarm Description: A pump monitor which displays the pump rate in gallons per minute with an audible and visual alarm output which will warn the operator of excessively low flow conditions under 5.00 GPM. The alarm should not be able to be silenced and should be reset when any front- ...

  • Baldor DTM8000 - page 18

    16 Conveyor Oven T ime Monitor with Over-Heating Alarm Description: An oven monitor displaying the tunnel time in minutes and seconds. The tunnel time is defined as the time it takes for the heated object on the conveyor to travel from point A to point B in the application diagram below. A visual indicator should activate if the tunnel time r ...

  • Baldor DTM8000 - page 19

    17 T ake-up / Pay-out Reel Material Measurement with Alarm Description: A take-up / pay-out system where the DTM8000 displays a measurement of dispensed or accumulated material in linear yards. Once the desired amount of material, 1500 yards, has been dispensed or accumulated, an external light should illuminate to indicate that the specified mater ...

  • Baldor DTM8000 - page 20

    18 Bi-directional Increment al Position Display Description: A system is needed which will track the position of a bi-directional linear-motion platform and allow the user to select a home or zero position. The display should read in inches and indicate the position of the platform at all times. Application Diagram: Wiring Diagram: Parameter Config ...

  • Baldor DTM8000 - page 21

    19 Problem Po ssible Case Solution Dis play is blank Power not appl ie d Defec t ive unit Using a v olt me ter, ver ify t hat a vol tage between 85 and 265VA C is measure d bet ween the L and N terminal bl oc k posi t ions. Contact t echnic al support for addi tional help and i nstr uc tio ns. Dis pl ay is dim Dis pl ay i nt ensit y paramet er is t ...

  • Baldor DTM8000 - page 22

    20 - Notes - ...

  • Baldor DTM8000 - page 23

    21 - Notes - ...

  • Baldor DTM8000 - page 24

    BALDOR ELECTRIC COMP ANY P .O. Box 2400 Ft. Smith, AR 72902–2400 (479) 646–471 1 Fax (479) 648–5792 www .baldor .com  Baldor Electric Company MN1327 Printed in USA 04/03 CH TEL: +41 52 647 4700 F AX: +41 52 659 2394 D TEL: +49 89 90 50 80 F AX: +49 89 90 50 8491 UK TEL: +44 1454 850000 F AX: +44 1454 859001 I TEL: +39 1 1 562 4440 F AX: +3 ...

メーカー Baldor カテゴリー Automobile Parts

Baldor DTM8000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DTM8000の取扱説明書
- Baldorの製品カード
- パンフレット
- またはBaldor DTM8000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Baldor DTM8000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Baldor DTM8000の取り付け説明書、サービスマニュアル、簡易説明書、またはBaldor DTM8000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Baldor DTM8000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Baldor DTM8000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBaldor DTM8000を使用するのを助ける技術的文書のことです。説明書は通常、全てのBaldor DTM8000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Baldorの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Baldor DTM8000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBaldor DTM8000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Baldor DTM8000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Baldor DTM8000デバイスの基本機能を使うにあたってのヒント。 Baldor DTM8000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Baldor DTM8000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBaldor DTM8000のメーカー/サービスへの連絡先に関する情報。

Baldor DTM8000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBaldor DTM8000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBaldor DTM8000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (1)

Maurizio

Buongiorno non riesco a scaricare il manuale in italiano di Allen & Heath 10fX grazie mkiage