    Installer Manual 1 INSTALLER MANUAL VER. B ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 2

    Installer Manual 2 Customer Information 1. The ORBIT-6 (Model RP-206) complies with FCC Part 68 Rules. On the upper panel of this product is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN is 0.8B). If requested, this information must be provided to the Telephone Company. 2. An FCC comp ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 3

    Installer Manual 3 Copyright © 2001 by Rokonet Ltd., 14 Hachoma Street Rishon Letzion 75655 Israel All rights reserved. No part of this document may be reproduced in any form without prior written permission from the publisher. 5IN206IM B ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 4

    Installer Manual 4 Summary of User’s Commands This page, called a Command Summary, is intended to give you brief summaries of common system operations. More detailed explanations and related information can be found within, by referring to the user manual. FUNCTION PROCEDURE System Arming [USER CODE] + [ARM] Stay Home Arming [USER CODE] + [STAY] ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 5

    Installer Manual 5 TABLE OF CONTENTS Introduction to the ORBIT-6 .................................................................. 6 Main Features: .................................................................................. 6 Installation ............................................................................................ 7 Before Y ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 6

    Installer Manual 6 INTRODUCTION TO THE ORBIT-6 The ORBIT-6 is intended to address the needs of many homes, offices, and small businesses. Its operation is designed around microprocessor and EEPROM (Electrically Erasable Programmable Read-Only Memory) technology, which stores, without the need for a source of power, the system’s operating program ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 7

    Installer Manual 7 INSTALLATION Before You Begin Be sure the actual work is performed by experienced personnel, licensed to carry out security system installations and capable of implementing all applicable requirements of the National Fire Protection Association (NFPA-70 and NFPA-74), as well as any federal, state, and local codes–along with any ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 8

    Installer Manual 8 TECHNICAL DATA Main Panel Input power 16.5 V AC 25 VA via transformer Rechargeable standby battery 12 V 4 A-Hours Auxiliary Power 12 V DC 250 mA maximum Bell/LS Sounder output 12 V DC 750mA maximum Programmable output Open collector Active pull down 70mA maximum Cabinet Dimensions: 260X218X83 mm (10.2X5.1X3.3 “) Weight 1.84 kg ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 9

    Installer Manual 9 INSTALLER PROGRAMMING The keypad The Orbit-6 can support up to 4 keypads, with a choice of 3 styles, 1 LCD type and two LED types from which virtually all features may be accessed. In addition to the functions it provides for the user, each of the keypads can be used by an installer to program the system parameters. An attempt to ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 10

    Installer Manual 10 Programming your Orbit-6 Programming Methods Local Requirements LED or LCD keypads The keypad must be wired to the Orbit- 6 panel. Power must be applied to the Orbit-6. Orbit Programmer Easy programming of the control panel parameters with menu driven LCD display. The programmer can store up to 10 Orbit-6 programming sets and co ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 11

    Installer Manual 11 Viewing the Contents of a Location It’s often necessary to check the data stored in a memory location to be sure it’s correct. If improper data is found, it must be corrected in order to obtain the desired system response. The data in a location can either be a number (from 0-9) or a letter (from A-F). Doing so takes advanta ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 12

    Installer Manual 12 Locations Whose Contents Occupy More Than One Digit When a location contains more than one digit, they cannot be viewed simultaneously. As soon as a location is accessed, the first digit is displayed automatically. Additional digits (if they exist) can be displayed by pressing the following keys: Used to display the next digit i ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 13

    Installer Manual 13 Operation Action Comments 1 Enter the Installer Programming mode enter the factory default Installer Code ( 0-2-0- 6 ); followed by # a long beep will sound, confirming successful entry into Installer Programming 2 Access the current Installer Code (stored in location “ 08 ”) press [0] , [ 8 ] , [ARM] no confirming beep will ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 14

    Installer Manual 14 GENERAL SYSTEM PARAMETERS: LOCATIONS 00–05 Location: 00 Default En able : Def: 00 PURPOSE: to enable or disable the option of resetting the system to the factory defaults. 00 Enable the option of resetting the system to the factory defaults. 55 Disable the option of resetting the system to the factory defaults. Location: 0 1 M ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 15

    Installer Manual 15 Location: 04 Callback UD Phone # Enables greater security for remote Upload/Download operation. This is a number to which the alarm company computer, equipped with the U/D software, will be connected. When a call is made from a computer, using U/D software, to the Orbit-6 panel, the system will hang-up and call back using this U ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 16

    Installer Manual 16 Location: 09 Installer Code II Default: 1206 Same as the Installer Code 1, but with a few limitations: It can't modify the "default code", observe and modify the first installer's codes, modify any MS phone number, nor observe & modify MS lock code. Location: 10 Master Code Default: 1234 PURPOSE: to estab ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 17

    Installer Manual 17 Locations: 14- 21 Zone 1-8 : (1 st Digit): Type Default: 1 st Digit Zone Type and Comments 0 Not Used All unused zones should be given this designation. It is also used to disable a zone 1 24-Hour A violation of such a zone will always cause an instant intrusion alarm, regardless of the system’s armed/disarmed state 2 Instant ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 18

    Installer Manual 18 Locations: 14-21 Zone 1-8: (2 nd Digit): Sound Default: 2 nd Digit Zone Sound and Comments 0 Silent a violation during the armed period will produce no sound the resulting alarm can still be reported to the Central Station 1 (default) External Sounder (Continuous) causes the external sounding device to annunciate steadily, witho ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 19

    Installer Manual 19 Location: 18 Zone 5: (2 nd Digit): Sound Default: External Sounder (Pulses) For fire zone the recommended (default) zone sound is “External sounder pulsed” However it is possible to change the zone sound and type to any of the ones provided in the previous list. Location: 19 Zone 6: Tamper Zone Zone 6 is reserved as a Tamper ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 20

    Installer Manual 20 Digit Event and Result 00 (default) Not Active UO offers no response to any system activity 01 Arm Follow (Latch) U0 is activated when the system is armed. The activation occurs after the expiration of the exit/delay period. The U0 remains active (latched) while the system is armed. When disarming the system the U0 deactivates ( ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 21

    Installer Manual 21 17 Special Emergency Keying Follow (Latched) UO is activated immediately when pressing the keypad’s [7] and [8] keys simultaneously for two seconds. U0 is deactivated when the system is disarmed. 18 Special Emergency Keying Follow (Pulsed) UO is activated for several seconds when pressing the keypad’s [7] and [8] keys simult ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 22

    Installer Manual 22 24 Duress Code Follow (Latched) UO is activated when any duress code is entered. The UO deactivates either when arming the system or disarming the system due to an alarm that was activated from the emergecy keypad keys, 24-hour zone violation or tamper zone violation. 25 Follow Chime (Pulse) ( Ver. 1.2) UO is activated for sever ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 23

    Installer Manual 23 Location: 2 6 Dialer Controls: (2 nd Digit): 2 nd Digit Attempts Answering Machine UL Installation Voice Module 0 3 No No No 1 8 No No No 2 3 Yes No No 3 (default) 8 Yes No No 4 3 No Yes No 5 8 No Yes No 6 3 Yes Yes No 7 8 Yes Yes No 8 3 No No Yes 9 8 No No Yes A 3 Yes No Yes B 8 Yes No Yes C 3 No Yes Yes D 8 No Yes Yes E 3 Yes ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 24

    Installer Manual 24 Understanding the Code Format To understand and modify the Code format according to a specific central station see the following • First digit: determine the number corresponding to the desired combination of: Kissoff/Handshake Freq / Message Validation / Extended–Non-Extended Format) • Second digit: determine the number ( ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 25

    Installer Manual 25 Location: 28 CS Protocols: When selecting a contact ID & SIA format, all the reporting codes will be automatically applied to the locations of the reporting codes. To change a code, enter a new code (according to the type of event – see page 30 ) to the corresponding location. When selecting the Pulsed Protocol the default ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 26

    Installer Manual 26 Comments on System Controls (Location 30: 2 nd Digit) Silent Panic Bell Squawk on Arming 3 Minute Bypass Enabled If “NO”, the panic alarm will be AUDIBLE at the External Sounder and visual on the keypad. If “YES”, the panic alarm will be INAUDIBLE at the External Sounder and invisable on the keypad. If selected, Bell Squ ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 27

    Installer Manual 27 System Controls: 1 ST Digit System Controls: 2 nd Digit PERIODIC TEST TIME: LOCATION 31 If desired, the ORBIT-6 can send a daily test transmission to the Central Station to verify the operation of the unit’s Digital Communicator. Location: 31 Periodic Test Time Default: 0000 Sets a fixed, daily time for sending an ORBIT-6 test ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 28

    Installer Manual 28 Other Reporting Codes Location Description Digits Default Report Code 54 Daily test Report Code sent everyday at the time specified in Location 24 2 00 55 User 0 arm (the “Master” Code, “Quick Ar m” OR “Keyswitch” Arm) 2 00 56 User 1 arm Reporting code 2 00 57 User 2 arm Reporting code 2 00 58 User 3 arm Reporting co ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 29

    Installer Manual 29 ORBIT-6 Installer Programming Worksheet Customer ________________________ Address _________________________ City ____________ State _____Zip ___ Customer Phone No: ( ) ___________________ Central Station Account No:___________________ Comments:________________________________ Date of Installation: ________________ Installer(s): ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 30

    Installer Manual 30 CONTACT ID & SIA REPORT CODES FOR ORBIT 6 Event Reporting Contact ID SIA Zones Alarms/Disarm Program Digit Code Program Digit Code Exit/Entry Alarm 01 134 01 BA Exit/Entry Restore 01 134 02 BH Burglary Zone Alarm 03 130 03 BA Burglary Zone Restore 03 130 04 BH 24 Hour Zone Alarm 05 133 05 BA 24 Hour Zone Restore 05 133 06 BH ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 31

    Installer Manual 31 Event Reporting Contact ID SIA Zones Alarms/Disarm Program Digit Code Program Digit Code Low Temperature Alarm/Restore 34 159 34 DA Los of Air Flow 35 161 35 DB Special Special Emergency Key Alarm 4A 100 4A MA Special Emergency Key Restore 4A 100 41 MH Fire Zone Alarm 42 110 42 FA Fire Zone Restore 42 110 43 FH Fire Key Alarm 44 ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 32

    Installer Manual 32 TI P RIN G TELEPHON E SE T TO TELEPHON E LINE TR1 ORBIT-6 Wiring Diagram FIGURE 1 A SET LINE PHO NE UR 1 P 1 J 2 J 1 DEFAUL T TYPICAL FIR E ZONE WIRING S (4 WIRE SMOKE DETECTIONS ) Z5 CO M UO AU X +I N -I N +OU T 12VD C SUPERVISIN G RELAY +OUT ALARM CONTACT END OF LINE RESISTOR S 2,2 K 1/4 WAT T UR 1 UR 1 TO ZONES CONTACT S AUX ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 33

    Installer Manual 33 12VD C 750 m A MAX N/ C CONTACT S TO KEYPAD(S) TI P RIN G TELEPHON E SE T TO TELEPHON E LINE TR1 ORBIT-6 Wiring Diagram FIGURE 1 B S E T L IN E P H O N E UR 1 P 1 J 2 J 1 DEFAUL T TYPICAL FIR E ZONE WIRING S (4 WIRE SMOKE DETECTIONS ) +I N -I N +OU T 12VD C SUPERVISIN G RELAY ALARM CONTACT END OF LINE RESISTOR S 2,2 K 1/4 WAT T ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 34

    Installer Manual 34 Zone Extension Power LED Arm LED Ready LED Fire LED Zone 1 Zone 2 Zone 3 Backlit LEDS Zone 4 Zone 5 Zone 6/Tmp Zone 7 Zone 8 AUX GND CLK DAT WHT RED BLK YEL GRN ( Keypad Buzzer ) Panic Button ∩ ∩ To FIGURE 1C the 8-ZONE KEYPAD BOARD Control Panel Z7 COM Z8 ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 35

    Installer Manual 35 Notes ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 36

    Installer Manual 36 ...

  • Rokonet Rokonet ORBIT-6 RP-206 - page 37

    Installer Manual 37 ROKONET LIMITED WARRANTY Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 18 months from the date of production. Because Seller does not install or connect the product and because the product may be u ...

Fabricant Rokonet Catégorie Smoke Alarm

Les documents que nous recevons du fabricant de l'appareilRokonet Rokonet ORBIT-6 RP-206 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Rokonet
- manuels d’utilisations ORBIT-6 RP-206
- fiches produit Rokonet
- dépliants
- ou étiquettes-énergie Rokonet Rokonet ORBIT-6 RP-206
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Rokonet Rokonet ORBIT-6 RP-206.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Rokonet Rokonet ORBIT-6 RP-206, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Rokonet Rokonet ORBIT-6 RP-206. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Rokonet Rokonet ORBIT-6 RP-206.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Rokonet Rokonet ORBIT-6 RP-206, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Rokonet Rokonet ORBIT-6 RP-206 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Rokonet Rokonet ORBIT-6 RP-206.

Le manuel d’utilisation complet Rokonet, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Rokonet Rokonet ORBIT-6 RP-206 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Rokonet Rokonet ORBIT-6 RP-206, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRokonet Rokonet ORBIT-6 RP-206 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Rokonet Rokonet ORBIT-6 RP-206 - qui devraient nous aider dans les premières étapes lors de l'utilisation Rokonet Rokonet ORBIT-6 RP-206
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Rokonet Rokonet ORBIT-6 RP-206
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Rokonet Rokonet ORBIT-6 RP-206 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Rokonet Rokonet ORBIT-6 RP-206?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Rokonet Rokonet ORBIT-6 RP-206, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Rokonet Rokonet ORBIT-6 RP-206 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)