Manuel d’utilisation Lochinvar SMART TOUCH 1

20 pages 1.84 mb
Télécharger

Aller à la page of 20

Summary
  • Lochinvar SMART TOUCH 1 - page 1

    Th i s m an ua l m us t o nl y b e u se d b y a qualified heating installer / serv ice technician. Read all instructions, including this manual, the SYNC Installation and Operation Man ual, and the SYNC Serv ice M anual, before installing. Perform steps in the order given. Failure t o comply could result in sev ere personal injur y , death, or subs ...

  • Lochinvar SMART TOUCH 1 - page 2

    2 Contents 1. INST ALLA TION Program Installation ..................................................... 3 USB Installation............................................................ 3 Program Setup ............................................................. 3 PC to Unit Connection.................................................. 3 S tarting the ...

  • Lochinvar SMART TOUCH 1 - page 3

    PC Program Instructions 1 Installa tion Prog r am installa tion There are tw o programs available for programming and monitoring the SYNC boilers. SITECS937L ab is used to monitor the operation of the boiler and program a few display- related parameters . SMAR T TOUCH PC i s u s e d t o p r o g r a m the bulk of the parameters in the contr ols. T o ...

  • Lochinvar SMART TOUCH 1 - page 4

    4 1 Installa tion Star ting the prog r am T o start one of the programs, double-click on the ic on (if you put it on your desktop), or click on Start, then Programs, and select the program you wish to start. See FIG 1-1 and FIG 1-2 abov e. There are tw o access levels for this program. The user access level allows only c er tain settings to be chan ...

  • Lochinvar SMART TOUCH 1 - page 5

    2 Sta tus Scr een 5 Figure 2-1 SMART TOUCH S tatus Screen T o monitor and r e cor d the oper ation of the heater , click on the Status tab along the top of the Main Scr een w indow (FIG. 1-1, page 4). W hen using the SITECS937Lab progr am, you will need to choose whic h controller you wish to monitor . The Status Screen will appear (see FIG. 2-1 ab ...

  • Lochinvar SMART TOUCH 1 - page 6

    2 Sta tus Scr een 6 At the t op r ight of the window is the Fan Speed status information. I ncluded in the Fan Speed status are Min., Max., and Ignition fan speeds. If Ramp Delay is activat ed, the Ramp Delay limit is sho w n. The target and actual fan speeds are display ed, and if the ac tual speed is within acceptable limits. If the SMART T OUCH ...

  • Lochinvar SMART TOUCH 1 - page 7

    7 3 Gr aphics Scr een The Graphics Screen allows y ou to observe the changes in various readings while the heater operates (see FIG. 3-1). N ote that the vertical scale has two numbers for each division. By default, the Outlet T emperature, Inlet T emperature, System Supply T emperature (if connected), Outdoor T emperature (if connect ed), T ank Se ...

  • Lochinvar SMART TOUCH 1 - page 8

    8 4 F ault Histor y Screen Figure 4-1 Fault History Screen The Fault Hist or y Screen provides historical data about the operation of the SMAR T TOUCH co nt rols.. Click on the Fault history button along the top of the Main Screen window (FIG. 1-1), and then click on Read from Control in the pull-down menu. After uploading data fr om the selected p ...

  • Lochinvar SMART TOUCH 1 - page 9

    9 5 Cascade Screen Figure 5-1 Cascade Screen The Cascade Screen pro v ides the status of the cascade system. The PC must be connect ed to the Leader (address 0-1) appliance. Click on the Cascade button along the top of the Main Scr e en window (FIG. 1-1). The Cascade Syst em area shows the powe r demand and setpoint, the boiler pump status, the boi ...

  • Lochinvar SMART TOUCH 1 - page 10

    6 P ar ameter s Parameter infor mation screens By acc essing the Parameter I nformation Screens on the SMAR T TOUCH program, the installer can v iew all of the SMAR T TOUCH parameters. The installer can also change certain specific parameters to fine tune the operation of the boiler to the installation. NOTE The PC cable m ust be connected to eithe ...

  • Lochinvar SMART TOUCH 1 - page 11

    11 6 P ar ameter s (continued) Changeable par ameter s The following is a brief discussion of the changeable parameters, their default setting s, the range of adjustment, and their location. The title for the par ameters ma y differ slightly from the PC to the boiler displa y . T o prevent confusion, the boiler display v ersion w ill be listed in p ...

  • Lochinvar SMART TOUCH 1 - page 12

    12 PC Program Instructions 6 P ar ameter s Set 2: Functional Data Set 2 is accessed b y clicking on Parameters at the t op of the Main Scr een window , then clicking on Set 2: Functional Data on the pull-down menu (FIG. 6-1, page 10). Cascade control P arameters 2DJ and 2DK determine the time dela ys used by the Cascade. T o access the Cascade para ...

  • Lochinvar SMART TOUCH 1 - page 13

    13 PC Program Instructions 6 P ar ameter s (continued) Pa r a m e t e r 2EB sets the pump delay time for the boiler pump after an ov er-temperature c ondition. This time is adjustable from 0 minut es to 40 minutes. The default time is 2 minutes. If the boiler pump or HW pump have not been activ e in a 24 hour period, the SMAR T TOUCH will activate ...

  • Lochinvar SMART TOUCH 1 - page 14

    14 PC Program Instructions 6 P ar ameter s SH off-on differential (SH off/on df) The SH Off-on Differential sets ho w many degrees below the turn-off temperature the outlet temperatur e has to go before the boiler will turn on. This parameter can be changed b y accessing parameter 4AE . The temperature range of this parameter is 0°F to 86°F . The ...

  • Lochinvar SMART TOUCH 1 - page 15

    15 PC Program Instructions 6 P ar ameter s (continued) T ank differential temp This parameter determines how far belo w the tank setpoint the tank sensor temperature must go t o star t a HW call for heat. This setting can be adjusted by accessing parameter 4A T . The temperature range is 0°F (0°C) to 100°F (38°C). The default value is 5°F (3.5 ...

  • Lochinvar SMART TOUCH 1 - page 16

    16 PC Program Instructions 6 P ar ameter s Cascade Each burner control in the Cascade m ust be given a unique address. This address can be changed by ac cessing parameter 4CC . The Leader (top) burner (to which the thermostat/zone control, system sensor , and system pump (if controlled by the boiler) are c onnected) must be set t o address 0. All t ...

  • Lochinvar SMART TOUCH 1 - page 17

    17 PC Program Instructions 6 P ar ameter s (continued) Figure 6-10 Parameter Set 4F OA reset water temp at min outdoor temp (4FC) (Reset T Lo Out) W h en the outdoor air t emperature drops to its minimum setting ( 4FC ), the water temperature setpoint will be at this value. Howev er , if the SH user setpoint ( 4AA ) is lower , it will ov er ride th ...

  • Lochinvar SMART TOUCH 1 - page 18

    18 PC Program Instructions 6 P ar ameter s Figure 6-1 1 Outdoor Air Reset Curve Figure 6-12 Parameter Set 4G BMS Setpoint at min volt age (BMS setpt min V) If par ameter 4CB is set t o 2, the co ntrol must kno w what minimum setpoint temperature t o use. This can be changed b y accessing parameter 4GA . The temperature range for this parameter is 3 ...

  • Lochinvar SMART TOUCH 1 - page 19

    19 PC Program Instructions 6 P ar ameter s (continued) Figure 6-13 Save Parameter File Window Storing p arameters on your PC Once y ou have customiz ed the parameters for a particular heater , y ou can store the new settings on your PC. This w ill allow y ou to restor e these settings should you ha ve to replac e the SMAR T TOUCH c ontrol, or allo ...

  • Lochinvar SMART TOUCH 1 - page 20

    Revision Notes: Revision A initial release. SYNC-PCP Rev A Printed in the USA 4/10 ...

Fabricant Lochinvar Catégorie Laptop

Les documents que nous recevons du fabricant de l'appareilLochinvar SMART TOUCH 1 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lochinvar
- manuels d’utilisations SMART TOUCH 1
- fiches produit Lochinvar
- dépliants
- ou étiquettes-énergie Lochinvar SMART TOUCH 1
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lochinvar SMART TOUCH 1.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lochinvar SMART TOUCH 1, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lochinvar SMART TOUCH 1. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lochinvar SMART TOUCH 1.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lochinvar SMART TOUCH 1, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lochinvar SMART TOUCH 1 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lochinvar SMART TOUCH 1.

Le manuel d’utilisation complet Lochinvar, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lochinvar SMART TOUCH 1 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lochinvar SMART TOUCH 1, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLochinvar SMART TOUCH 1 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lochinvar SMART TOUCH 1 - qui devraient nous aider dans les premières étapes lors de l'utilisation Lochinvar SMART TOUCH 1
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lochinvar SMART TOUCH 1
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lochinvar SMART TOUCH 1 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lochinvar SMART TOUCH 1?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lochinvar SMART TOUCH 1, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lochinvar SMART TOUCH 1 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)