    SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE, LOW ENERGY AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. beasensors.com REV BY: KJG JEG 80.0011.02 SCALE: DATE: NONE 24 APR 2005 PART NO: SHEET 1 OF 1 NOTE: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, ...

  • BEA 80.0011.02 - page 2

    DWG NO SIZE SHEET SCALE CAGE CODE PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: ENG'G FILE OF: DRAWN BY: REV 01 24 VAC MC-25 #1 PUSH PLATE DOOR CONTROL WITH ELECTRIC STRIKE ELECTRIC STRIKE RECTIFIER ISO24 RELAY DOOR CONROL WITH AUTOMATIC FLUSH BOLTS 110 VAC brown orange jumpers on 1&2/ ...

  • BEA 80.0011.02 - page 3

    DWG NO SIZE SHEET SCALE CAGE CODE A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: FILE OF: DRAWN BY: REV TITLE: PAIR OF DOORS WITH MC25, ELECTRIC STRIKE AND MANUAL FLUSH BOLTS PUSH PLATE MC25 #2 DRY CONTACT LO-21S LOCK OUT RELAY DOOR CONTROL #1 ISO24 RELAY MC25 #1 WET CONTACTS ELECTRIC STRIKE M ...

  • BEA 80.0011.02 - page 4

    PH: (412) 249-4100 FAX: (412) 249-4101 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: SHEET: SCALE: A REV: DRAWN BY: SIZE: CAGE CODE: DWG NO: FILE OF: B.E.A., Inc. ENG'G JED 80.0015 01 1 OF 1 NONE 02 JAN 04 purple (N/C) red (COM) RELAY 2 RELAY 1 Activation blue yellow DOOR CONTROL MAGLOCK + - DOOR POSITION SWITCH BRIDGE RECTIFIER 24 V TRANSF ...

  • BEA 80.0011.02 - page 5

                                                                        ! " # $ %  ...

  • BEA 80.0011.02 - page 6

    A FILE OF: DRAWN BY: 1 OF 1 NTS CAGE CODE: DWG NO: REV: SIZE: SHEET: SCALE: DATE: NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS. 2) BRIDGE RECTIFIER SUPPLIED BY OTHERS. 80.0017 JED 01 02 JAN 04 TITLE: MC-25 WITH SEPERATE POWER SUPPLY FOR MAGLOCK ENG'G purple (N/C) red (COM) RELAY 2 RELAY 1 Activation blue yell ...

  • BEA 80.0011.02 - page 7

    SIZE: DRAWN BY: TITLE: MC-25 w/ SARGENT EL PANIC DEVICE & AUTOMATIC DOOR OPERATOR A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. beasensors.com REV BY: KJG KJG 80.0018.02 SCALE: DATE: NONE 17 MAY 2005 PART NO: SHEET 1 OF 1 COM DOOR CONTROL ACT RED COMMON BLACK N/O COM N/O 24 V TRANSFORMER SARGE ...

  • BEA 80.0011.02 - page 8

    SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, APT. BUZZER RELAY/ FIRE ALARM A NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VO LT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE. 4) ...

  • BEA 80.0011.02 - page 9

    SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVERS, SEPARATE POWER SUPPLY FOR MAGLOCK, NIGHT MODE RELAY A NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS. 2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLT S). 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. ...

  • BEA 80.0011.02 - page 10

    SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE. 100 ENTERPRISE DRIV ...

  • BEA 80.0011.02 - page 11

    DWG NO SIZE SHEET SCALE CAGE CODE PH: (412)782-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: NONE FILE OF: DRAWN BY: REV MC25 #2 TRANSFORMER KM 2000 DOOR CONTROL ACTIVATION com n/o red black gray gray orange brown red blue yellow black 120 VAC DOOR #2 MOTOR blue yellow orange white RECTIFIER ISO 24VAC COIL D ...

  • BEA 80.0011.02 - page 12

    SIZE: DRAWN BY: TITLE: MC-25 WITH 3 WIRE RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRE ...

  • BEA 80.0011.02 - page 13

    SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT / AMPERE RATING IS DETERMIND BY CURRENT DRA ...

  • BEA 80.0011.02 - page 14

    SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, MAGNETIC LOCK, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW O ...

  • BEA 80.0011.02 - page 15

    SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC PANIC, PUSHPLATE AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. beasensors.com REV BY: KJG JDC 80.0142.02 SCALE: DATE: NONE 20 MARCH 2006 PART NO: SHEET 1 OF 1 NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR ...

  • BEA 80.0011.02 - page 16

    SIZE: DRAWN BY: TITLE: 2 MC-25s WITH ELECTRIC STRIKE, SEQUENCING 2 DOOR PANELS A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC STRIKE. 100 ENTERPRISE DRIV ...

  • BEA 80.0011.02 - page 17

    SIZE: DRAWN BY: B 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL : www.be ase nso rs. com REV BY: KJG JDC SCALE: DATE: NONE 20 MARCH 2006 PART NO: SHEET 1 OF 1 80.0164.02 TITLE: MC-25, LE-21 WITH LO-21, BODYGUARD, APPROACH SIDE SUPERSCA NS NOTE: 1) ENSURE THAT A MINIMUM OF 3 SECONDS OF HOLD OPEN TIME IS LE ...

Fabricant BEA Catégorie Door

Les documents que nous recevons du fabricant de l'appareilBEA 80.0011.02 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques BEA
- manuels d’utilisations 80.0011.02
- fiches produit BEA
- dépliants
- ou étiquettes-énergie BEA 80.0011.02
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation BEA 80.0011.02.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation BEA 80.0011.02, manuels d’entretien, brefs manuels ou manuels de l’utilisateur BEA 80.0011.02. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit BEA 80.0011.02.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil BEA 80.0011.02, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser BEA 80.0011.02 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs BEA 80.0011.02.

Le manuel d’utilisation complet BEA, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel BEA 80.0011.02 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières BEA 80.0011.02, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBEA 80.0011.02 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil BEA 80.0011.02 - qui devraient nous aider dans les premières étapes lors de l'utilisation BEA 80.0011.02
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de BEA 80.0011.02
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service BEA 80.0011.02 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de BEA 80.0011.02?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec BEA 80.0011.02, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec BEA 80.0011.02 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)