BEA 80.0011.02 - page 1
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE, LOW ENERGY AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. beasensors.com REV BY: KJG JEG 80.0011.02 SCALE: DATE: NONE 24 APR 2005 PART NO: SHEET 1 OF 1 NOTE: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, ...
-
BEA 80.0011.02 - page 2
DWG NO SIZE SHEET SCALE CAGE CODE PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: ENG'G FILE OF: DRAWN BY: REV 01 24 VAC MC-25 #1 PUSH PLATE DOOR CONTROL WITH ELECTRIC STRIKE ELECTRIC STRIKE RECTIFIER ISO24 RELAY DOOR CONROL WITH AUTOMATIC FLUSH BOLTS 110 VAC brown orange jumpers on 1&2/ ...
-
BEA 80.0011.02 - page 3
DWG NO SIZE SHEET SCALE CAGE CODE A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: FILE OF: DRAWN BY: REV TITLE: PAIR OF DOORS WITH MC25, ELECTRIC STRIKE AND MANUAL FLUSH BOLTS PUSH PLATE MC25 #2 DRY CONTACT LO-21S LOCK OUT RELAY DOOR CONTROL #1 ISO24 RELAY MC25 #1 WET CONTACTS ELECTRIC STRIKE M ...
-
BEA 80.0011.02 - page 4
PH: (412) 249-4100 FAX: (412) 249-4101 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: SHEET: SCALE: A REV: DRAWN BY: SIZE: CAGE CODE: DWG NO: FILE OF: B.E.A., Inc. ENG'G JED 80.0015 01 1 OF 1 NONE 02 JAN 04 purple (N/C) red (COM) RELAY 2 RELAY 1 Activation blue yellow DOOR CONTROL MAGLOCK + - DOOR POSITION SWITCH BRIDGE RECTIFIER 24 V TRANSF ...
-
BEA 80.0011.02 - page 5
! " # $ % ...
-
BEA 80.0011.02 - page 6
A FILE OF: DRAWN BY: 1 OF 1 NTS CAGE CODE: DWG NO: REV: SIZE: SHEET: SCALE: DATE: NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS. 2) BRIDGE RECTIFIER SUPPLIED BY OTHERS. 80.0017 JED 01 02 JAN 04 TITLE: MC-25 WITH SEPERATE POWER SUPPLY FOR MAGLOCK ENG'G purple (N/C) red (COM) RELAY 2 RELAY 1 Activation blue yell ...
-
BEA 80.0011.02 - page 7
SIZE: DRAWN BY: TITLE: MC-25 w/ SARGENT EL PANIC DEVICE & AUTOMATIC DOOR OPERATOR A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. beasensors.com REV BY: KJG KJG 80.0018.02 SCALE: DATE: NONE 17 MAY 2005 PART NO: SHEET 1 OF 1 COM DOOR CONTROL ACT RED COMMON BLACK N/O COM N/O 24 V TRANSFORMER SARGE ...
-
BEA 80.0011.02 - page 8
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, APT. BUZZER RELAY/ FIRE ALARM A NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VO LT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE. 4) ...
-
BEA 80.0011.02 - page 9
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVERS, SEPARATE POWER SUPPLY FOR MAGLOCK, NIGHT MODE RELAY A NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS. 2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLT S). 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. ...
-
BEA 80.0011.02 - page 10
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE. 100 ENTERPRISE DRIV ...
-
BEA 80.0011.02 - page 11
DWG NO SIZE SHEET SCALE CAGE CODE PH: (412)782-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: NONE FILE OF: DRAWN BY: REV MC25 #2 TRANSFORMER KM 2000 DOOR CONTROL ACTIVATION com n/o red black gray gray orange brown red blue yellow black 120 VAC DOOR #2 MOTOR blue yellow orange white RECTIFIER ISO 24VAC COIL D ...
-
BEA 80.0011.02 - page 12
SIZE: DRAWN BY: TITLE: MC-25 WITH 3 WIRE RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRE ...
-
BEA 80.0011.02 - page 13
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT / AMPERE RATING IS DETERMIND BY CURRENT DRA ...
-
BEA 80.0011.02 - page 14
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, MAGNETIC LOCK, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW O ...
-
BEA 80.0011.02 - page 15
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC PANIC, PUSHPLATE AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www. beasensors.com REV BY: KJG JDC 80.0142.02 SCALE: DATE: NONE 20 MARCH 2006 PART NO: SHEET 1 OF 1 NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR ...
-
BEA 80.0011.02 - page 16
SIZE: DRAWN BY: TITLE: 2 MC-25s WITH ELECTRIC STRIKE, SEQUENCING 2 DOOR PANELS A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC STRIKE. 100 ENTERPRISE DRIV ...
-
BEA 80.0011.02 - page 17
SIZE: DRAWN BY: B 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL : www.be ase nso rs. com REV BY: KJG JDC SCALE: DATE: NONE 20 MARCH 2006 PART NO: SHEET 1 OF 1 80.0164.02 TITLE: MC-25, LE-21 WITH LO-21, BODYGUARD, APPROACH SIDE SUPERSCA NS NOTE: 1) ENSURE THAT A MINIMUM OF 3 SECONDS OF HOLD OPEN TIME IS LE ...