    NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property dam ...

  • Bryant 663C - page 2

    II. INSTALL ON A SOLID, LEVEL MOUNTING PAD If conditions or local codes require the unit be attached to pad, tie down bolts should be used and fastened through knockouts provided in unit base pan. Refer to unit mounting pattern in Fig. 3 to determine base pan size and knockout hole location. On rooftop applications, mount on level platform or frame ...

  • Bryant 663C - page 3

    VII. CHECK OUTDOOR CHECK-FLO-RATER® PISTON Check outdoor unit piston. Remove retainer on liquid service valve and check piston size with matching number listed on outdoor unit rating plate. VIII. CHECK DEFROST THERMOSTAT Check defrost thermostat to ensure it is properly located and securely attached. There is a liquid header with a brass distribut ...

  • Bryant 663C - page 4

    IMPORTANT: Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment. Ensure tubes are not rubbing against each other or any sheet metal. Pay close attention to feeder tubes, making sure wire ties on feeder tubes are secure and tight. X. MAKE ELECTRICAL CONNECTIONS WARNING: To avoid personal injury or death, ...

  • Bryant 663C - page 5

    WARNING: The unit cabinet must have an uninter- rupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes. Failure to follow this warning can result in an electric shock, fire, or death. B. Connect ...

  • Bryant 663C - page 6

    Fig. 9—Typical 24-v Circuit Connections using Bryant Model HP Thermostat with Fan Coils and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97400 24 VAC HOT       R G W/W1 Y/Y2 O/W2 R W3 W2 RVS COOLING         C B S1 S2 W2 BRYANT PROGRAMMABLE THERMOSTAT MODEL HP TWO? ...

  • Bryant 663C - page 7

    Fig. 10—Typical 24-v Circuit Connections using Other HP Thermostats with Fan Coils and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97404 24 VAC HOT       R C W2 Y G R W3 W2 G RVS COOLING         E W2 OTHER HP THERMOSTAT  TWO OUTDOOR THERMOSTATS  FA, FB ...

  • Bryant 663C - page 8

    Fig. 12—Typical 24-v Circuit Connections using Bryant Model 2S Thermostat with FK4C Fan Coil and Smart Staging A97405 24 VAC HOT       R G W/W1 Y/Y2 Y/Y2 Y1/W2 R DH RVS COOLING         C B L S1 S2 Y W2 BRYANT PROGRAMMABLE THERMOSTAT MODEL 2S FK4C FAN COIL HEAT  PUMP   G O O/W ...

  • Bryant 663C - page 9

    Fig. 13—Typical 24-v Circuit Connections using Bryant Model HP Thermostat with Smart Heat and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97409 24 VAC HOT       R G W/W1 Y/Y2 O/W2 RVS COOLING         C B S1 S2 SUPPLEMENTAL HEATING RELAY BRYANT PROGRAMMABLE THER ...

  • Bryant 663C - page 10

    Fig. 14—Typical 24-v Circuit Connections using Other HP Thermostats with Smart Heat and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97412 24 VAC HOT       R C Y G O RVS COOLING         W2 OTHER HP THERMOSTAT  HEAT  PUMP   E R C Y G O W2T W3 W2D Y 0 R C ...

  • Bryant 663C - page 11

    providing electrical potential to second heater sequencer (if used). If outdoor temperature falls below setting of outdoor thermostat (field-installed option), contacts close to complete circuit and bring on second bank of supplemental electric heat. When thermostat is satisfied, its contacts open, de-energizing contactor and sequencer. All heaters ...

  • Bryant 663C - page 12

    XIV. CHECK CHARGE Factory charge is shown on unit rating plate. To check charge in cooling mode, refer to Cooling Only Procedure. To check charge in heating mode, refer to Heating Check Chart Procedure. A. Cooling Only Procedure NOTE: If subcooling charging conditions are not favorable, charge must be weighed in accordance with unit rating plate ± ...

Fabricant Bryant Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilBryant 663C peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bryant
- manuels d’utilisations 663C
- fiches produit Bryant
- dépliants
- ou étiquettes-énergie Bryant 663C
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bryant 663C.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bryant 663C, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bryant 663C. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bryant 663C.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Bryant 663C, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bryant 663C par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bryant 663C.

Le manuel d’utilisation complet Bryant, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bryant 663C - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bryant 663C, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBryant 663C qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bryant 663C - qui devraient nous aider dans les premières étapes lors de l'utilisation Bryant 663C
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bryant 663C
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bryant 663C dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bryant 663C?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bryant 663C, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bryant 663C il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)