    323617A-01 May 2003 © 2003 National I nstruments Corp. Al l rights res erved. FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and company names ment ioned herein are trademark s or trade names of their respecti ve companies. For patents covering National Inst ruments product ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 2

    cFP-RLY-421 2 ni.com Before you conf igure a FieldPoint system that uses a cFP-RL Y -421 module, calculate the total power consumption of the I/O modules on the FieldPoint bank. Y ou ca n find the po wer requirement specification in the operating inst ructions for ea ch I/O module . The maximum power the netw ork module can supply is specified in t ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 3

    © National Instruments Corp. 3 cFP-RLY-421 Figure 1. Installing the cFP-RL Y -421 Wiring the cFP-RL Y -421 The cFP-CB- x connector block has conne ctions for each of the eight cFP-RL Y -421 relay channels and for an external supply to power f ield devices. If you are using the cFP-RL Y - 421 in a hazardous voltage application, you mu st use the cF ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 4

    cFP-RLY-421 4 ni.com T able 1 li sts the terminal assign ments for the signals of each channel. All of the COM terminals are conne cted internally and all of the V SUP terminals are connected inte rnally . NI does not recommend using them with the cFP-RL Y -421. Caution Cascading power between two modules defeats isolation between those modules. Ca ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 5

    © National Instruments Corp. 5 cFP-RLY-421 Connecting Loads to the cFP-RL Y -421 W ire an external po wer supply to the load and IC terminal of the individu al channel as shown in Figure 2. This method of wiring keeps the electrical connections of the cFP-RL Y -421 within safe current limits. Figure 2. Connecting a Load The cFP-RL Y -421 has eight ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 6

    cFP-RLY-421 6 ni.com In addition, the cFP-RL Y -421 has internal protection MO Vs to pre vent excessiv ely high voltag e from being applied across the contacts. The MO Vs are located between the NO and IC contacts of each relay . Howe ver , National Instruments still recommends the use of a protection circuit across an inductive load. The flyback p ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 7

    © National Instruments Corp. 7 cFP-RLY-421 Diode Circuit CR Circuits Varistor Circuit Diagram Notes Use in DC applications only . Compared to RC type, circuit delays release time (2 to 5 times values stated in catalog). For lar ger voltages, use diode with rev erse breakdo wn 10 times circu it voltage an d forward load circuit. For smaller v oltag ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 8

    cFP-RLY-421 8 ni.com In-Rush Current The type of l oad and its in-rush current charac teristics, together with switching frequency , can ca use contact welding. For loads with in-rush current, measure the steady state current and in-rush current to determine the proper rela y . Some typical types of loads and the in-rush current they create are sum ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 9

    © National Instruments Corp. 9 cFP-RLY-421 Upgrading the FieldPoint Firmware Y ou may need to upgrade the FieldPoint f irmware when you add ne w I/O modules to the FieldPoi nt system. For information on determining which fi rmware you need and ho w to upgrade the firmw are, go to ni.com/info and enter fpmatrix . Isolation and Sa fety Guidelines Ca ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 10

    cFP-RLY-421 10 ni.com •D o not share the exter nal supply voltages (the V and C terminals) with other de vices (including othe r FieldPoint de vices), unless those devices ar e isolated from human contact. • Y ou must connect the protecti ve ea rth (PE) ground terminal on the cFP-BP- x backplane to the syst em safety ground. The backplane PE gr ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 11

    © National Instruments Corp. 11 cFP-RLY-421 Specifications The follo wing specifications ar e typical for a range of – 40 to 60 °C unless otherwise noted. Relay Characteristics Number of channels ..................... ..... 8 Relay type ......... ...................... .......... 1 SPST , nonlatching Maximum switching ca pacity (resisti ve load ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 12

    cFP-RLY-421 12 ni.com Physical Indicators ..... .............. ........... ........... . Green POWER and READY indicators, 8 green output state indicators W eight cFP-RL Y -421 .................... .......... 130 g (4.5 oz) Power Requirements Power from network modul e ............ 1,700 mW Isolation Voltage Maximum isolation v oltage ............. ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 13

    © National Instruments Corp. 13 cFP-RLY-421 Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 3121-1, UL 61010C-1 • CAN/CSA C22.2 No. 1010.1 For UL, hazardous location, and othe r safety certifica ...

  • National Instruments EIGHT CHANNEL SPST RELAY MODULE - page 14

    cFP-RLY-421 14 ni.com Where to Go for Support For more information about settin g up the FieldPoint system, refer to these National Instruments documents: • FieldPoint network module user manual • Other FieldPo int I/O m odule operating instructions • FieldPoint connector bl ock operating instructions Go to ni.com/support for the most current ...

Fabricant National Instruments Catégorie Electronic Accessory

Les documents que nous recevons du fabricant de l'appareilNational Instruments EIGHT CHANNEL SPST RELAY MODULE peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations EIGHT CHANNEL SPST RELAY MODULE
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments EIGHT CHANNEL SPST RELAY MODULE
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments EIGHT CHANNEL SPST RELAY MODULE.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments EIGHT CHANNEL SPST RELAY MODULE, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments EIGHT CHANNEL SPST RELAY MODULE. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments EIGHT CHANNEL SPST RELAY MODULE.

Manuel d’utilisation complet de l’appareil National Instruments EIGHT CHANNEL SPST RELAY MODULE, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments EIGHT CHANNEL SPST RELAY MODULE par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments EIGHT CHANNEL SPST RELAY MODULE.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments EIGHT CHANNEL SPST RELAY MODULE - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments EIGHT CHANNEL SPST RELAY MODULE, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments EIGHT CHANNEL SPST RELAY MODULE qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments EIGHT CHANNEL SPST RELAY MODULE - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments EIGHT CHANNEL SPST RELAY MODULE
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments EIGHT CHANNEL SPST RELAY MODULE
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments EIGHT CHANNEL SPST RELAY MODULE dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments EIGHT CHANNEL SPST RELAY MODULE?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments EIGHT CHANNEL SPST RELAY MODULE, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments EIGHT CHANNEL SPST RELAY MODULE il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)