Manuel d’utilisation Xilinx ChipScope PLB46 IBA v1.00a

13 pages 0.31 mb
Télécharger

Aller à la page of 13

Summary
  • Xilinx ChipScope PLB46 IBA v1.00a - page 1

    DS619 April 7, 2009 www .xilinx.com 1 Product Specification © 2009 Xilinx, Inc. X ilinx, Inc. XILINX, the Xilinx lo go, V i rtex, Spartan, ISE and other designate d brands included herein are trademarks of Xilinx in th e United States and other countries. All other trad emarks are the property of their re specti ve owners. Intr oduction The ChipSc ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 2

    2 www .xilinx.com DS619 April 7, 2009 Product Specification ChipScope PLB46 IBA I/O Signals T able 1: IBA_PLBv46 Pin Descriptions Port MU Signal Name Interface I/O Description P1 CONTROL ICON I/O Icon control bus IO P2 PLB_Clk System I System Clock P3 MU_1C iba_trigin_in GENERIC I Generic T rigger Inputs P4 iba_trig_out GENERIC O IBA T rigger Outpu ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 3

    DS619 April 7, 2009 www .xilinx.com 3 Product Specification P32 MU_2B PLB_masterID[0: C_PLBV46_MID_WIDTH-1] Slave I PLB current ma ster identifier P33 MU_2B PLB_BE[0: C_PLBV46_DWIDTH/8-1] Slave I PLB byte enable s P34 MU_2C PLB_T Attribute[0:15] Sl ave I PLB Transfer Attribute Address P35 MU_3A PLB_ABus[0:31] Slave I PLB address bus, lower 32 bits ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 4

    4 www .xilinx.com DS619 April 7, 2009 Product Specification P54 MU_9 Sl_MWrErr[0: C_PLBV46_NUM_SLA VES *C_PLBV46_NUM_MASTERS-1] Slave I Slave write error indicator PLB Arbitr ation Signals P55 MU_10 M_request[0: C_PLBV46_NUM_MASTERS-1] Master I Master bus request P56 MU_10 M_priority[0: C_PLBV46_NUM_MASTERS*2-1] Master I Master bus request priority ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 5

    DS619 April 7, 2009 www .xilinx.com 5 Product Specification The IBA_PLBv46 por ts listed in Ta b l e 1 connect to the PLBv46 bus. The core divides related ports into 13 match unit groups (MUs) as shown i n the second column of the table. Each m atch unit group can conn ect to a trigger port of the IBA. Certain match unit groups, such as MU_1, are f ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 6

    6 www .xilinx.com DS619 April 7, 2009 Product Specification When these match units are enabled, all slaves or master s are enabled. Y ou canno t individually enable a particular master . The match units 7, 8, and 9 are slave side signals for BUSY , READ, and WRITE error controls going to the mas- ter . These units are broken out individually becaus ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 7

    DS619 April 7, 2009 www .xilinx.com 7 Product Specification G13 Enable T rigger Out C_ENAB LE_TRIGGER_OUT 1,0 0 Integer T rigger In, PLB Reset, and PLB Erro r S tatus G14 Use system rese t and error status signals C_USE_MU_1A_RST_ERR_ ST A T 1,0 1 Integer G15 Use master error status signals C_USE_MU_1B_MSTR_RST_ ERR_ST A T 1,0 0 Integer G16 Use iba ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 8

    8 www .xilinx.com DS619 April 7, 2009 Product Specification G32 1=Enable storing MU 3 signals in the data sample storage buffer . 0=Disable C_USE_MU_3A_ABUS or must C_USE_MU_3B_UABUS be 1 in order to store. C_MU_3_EN_STORE_ADDR 0,1 1 Integer PLB Data G33 Use PLB_wrDBus C_USE_ MU_4_WR_DBUS 1,0 0 Integer G34 0=basic, 1=basic w/ edges, 2=extended, 3= ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 9

    DS619 April 7, 2009 www .xilinx.com 9 Product Specification G46 1=Enable storing MU 6 signals in the data sample storage buffer . 0=Disable C_USE_MU_6A_SL V_CTL or C_USE_MU_6B_SL V_SZ_W ADD R must be 1 in order to store. C_MU_6_EN_STORE_SL V_ CTL_BUS 0,1 1 Integer Slave Busy S tatus G47 USE SI _MBusy signal C_USE_MU_7_SL V_BSY 1,0 0 Integer G48 0=b ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 10

    10 www .xilinx.com DS619 April 7, 2009 Product Specification Ta b l e 2 lists the IBA PLBv46 parameterized feat ures, which c ontrol the ports attached to the IBA trigger and stor- age units. They also are used to co nfigure the storage and match unit op tions available for each trigger port. The IBA ports are subdi vided into logical group s call ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 11

    DS619 April 7, 2009 www .xilinx.com 11 Product Specification Every match unit group has a match type and mat ch counter width parameter . The match unit type describes the type of compare operation that can be done on a match unit. Th e valid values for this type are defined for each match unit. For example, C_MU_1_TYPE only sup ports basic and bas ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 12

    12 www .xilinx.com DS619 April 7, 2009 Product Specification Design Implementation The ChipScope PLB IBA desi gn is implemented in a T cl script. Wh en the EDK Platgen tool is run, thi s T cl script is called and it internally calls the ChipScope Pro Core generator in command line mode providin g a generated argument (.ar g) file to create a custom ...

  • Xilinx ChipScope PLB46 IBA v1.00a - page 13

    DS619 April 7, 2009 www .xilinx.com 13 Product Specification Revision History Notice of Disclaimer Xilinx is providing this design, code, or inform ation (collectively , the “Information”) to you “ AS-IS ” with no warranty of any kind, express or implied. Xilinx makes no re presentation that the Information, or any particular implementation ...

Fabricant Xilinx Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilXilinx ChipScope PLB46 IBA v1.00a peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Xilinx
- manuels d’utilisations ChipScope PLB46 IBA v1.00a
- fiches produit Xilinx
- dépliants
- ou étiquettes-énergie Xilinx ChipScope PLB46 IBA v1.00a
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Xilinx ChipScope PLB46 IBA v1.00a.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Xilinx ChipScope PLB46 IBA v1.00a, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Xilinx ChipScope PLB46 IBA v1.00a. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Xilinx ChipScope PLB46 IBA v1.00a.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Xilinx ChipScope PLB46 IBA v1.00a, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Xilinx ChipScope PLB46 IBA v1.00a par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Xilinx ChipScope PLB46 IBA v1.00a.

Le manuel d’utilisation complet Xilinx, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Xilinx ChipScope PLB46 IBA v1.00a - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Xilinx ChipScope PLB46 IBA v1.00a, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lXilinx ChipScope PLB46 IBA v1.00a qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Xilinx ChipScope PLB46 IBA v1.00a - qui devraient nous aider dans les premières étapes lors de l'utilisation Xilinx ChipScope PLB46 IBA v1.00a
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Xilinx ChipScope PLB46 IBA v1.00a
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Xilinx ChipScope PLB46 IBA v1.00a dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Xilinx ChipScope PLB46 IBA v1.00a?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Xilinx ChipScope PLB46 IBA v1.00a, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Xilinx ChipScope PLB46 IBA v1.00a il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)